| 2018-05-27 11:21:21 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| | FBC B = FBC BUILDING |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | FBC R = FBC RESIDENTIAL |
| | |
| | NOTE - ALTHOUGH THE IMPROVEMENTS HAVE BEEN INSTALLED |
| | WITHOUT A PERMIT, COMMENT LIST REFERS TO IMPROVEMENTS |
| | AS "PROPOSED". AN IMPROVEMENT BECOMES "EXISTING" WHEN A |
| | PERMIT IS ISSUED, CONSTRUCTION INSPECTED, AND FINAL |
| | INSPECTIONS OBTAINED. |
| | |
| | 1. WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED |
| | SETS OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) |
| | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT |
| | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER |
| | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" |
| | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID. |
| | |
| | 2. AS THE ORIGINAL PERMIT WAS FOR "TEMPORARY |
| | CONSTRUCTION TRAILERS" WHICH ARE EXEMPT FROM FLORIDA |
| | BUILDING CODE, BUT ACTUAL USE IS AS A LOUNGE |
| | (18021162/18041012), COMPLIANCE WITH ALL REQUIREMENTS |
| | OF THE FLORIDA BUILDING IS REQUIRED. A DESIGN |
| | PROFESSIONAL IS REQUIRED TO PROVIDE ALL INFORMATION, |
| | FS481. A SKETCH AND "MODSPACE" DRAWING WERE PROVIDED; |
| | THIS CANNOT BE USED TO DEMONSTRATE CODE COMPLIANCE. AN |
| | INCOMPLETE "LIFE SAFETY PLAN" WAS SUBMITTED; PLEASE |
| | REVISE THIS PLAN TO ADDRESS COMMENTS, OR HAVE ANOTHER |
| | DESIGN PROFESSIONAL PREPARE A PLAN. |
| | |
| | 3. CONTACT PALM BEACH COUNTY IMPACT FEES, 561-233-5025. |
| | THEY WILL DETERMINE WHETHER OR NOT IMPACT FEES ARE |
| | REQUIRED. IF AN IMPACT FEE ASSESSMENT IS NOT REQUIRED, |
| | THEY CAN VERIFY THIS VIA EMAIL. IF THEY REQUIRE A |
| | REVIEW, AFTER ALL REVIEWS HAVE PASSED AND PLANS ARE |
| | STAMPED, TAKE THE PLANS TO PALM BEACH COUNTY. THE PLANS |
| | ARE TO BE STAMPED BY THEM AND THE RECEIPT SHOWING THAT |
| | FEES DUE WERE PAID, IF APPLICABLE, ARE TO BE PROVIDED |
| | TO BUILDING DIVISION. |
| | |
| | 3. PROVIDE THE DCA APPROVAL FOR THE STRUCTURE. THIS |
| | STRUCTURE HAS BEEN REVIEWED BY THE STATE. |
| | |
| | 4. REVISE SITE PLAN OR OTHER PLAN TO SHOW BUILDING TYPE |
| | (FBC CHAPTER 6), BUILDING AREA TO SHOW COMPLIANCE WITH |
| | FBC B CHAPTER 5. |
| | |
| | 5. DESIGN PROFESSIONAL IS TO DETERMINE PROPOSED |
| | OCCUPANCY (APPEARS TO BE ASSEMBLY?), OCCUPANT LOAD. IF |
| | OCCUPANCY IS NOT CONSISTENT WITH THE DCA APPROVAL, |
| | MODIFICATIONS WILL BE REQUIRED. |
| | |
| | A COMPLETE REVIEW CANNOT BE DONE WITHOUT THE DCA |
| | APPROVAL. AFTER RECEIPT OF THE DCA STATE APPROVED PLAN, |
| | A REVIEW BY ALL TRADES WILL BE REQUIRED IF THE |
| | OCCUPANCY REVIEWED IS NOT THE SAME AS PROPOSED |
| | OCCUPANCY. |
| | |
| | THE PLANS FOR THE ISSUED PERMIT WERE NOT AVAILABLE TO |
| | ME AT TIME OF REVIEW. PLEASE NOTE THAT THE DCA PLAN FOR |
| | ONE OF THE OTHER PERMITS, 18021164, WAS SUBMITTED BUT |
| | IS NOT LEGIBLE. IF SIMILAR APPROVAL WITH SIMILAR ISSUE |
| | (NOT LEGIBLE) WAS PROVIDED FOR THIS PERMIT AS WELL, |
| | PROVIDE A COMPLETELY LEGIBLE APPROVAL. |
| | |
| | 6. IT IS NOT CLEAR HOW THE PROPOSED DECK COMPLIES WITH |
| | FBC ACCESSIBLILITY. ARE THE BOARDS T&G? HOW LARGE ARE |
| | THE GAPS, SEE FBC A 302.3. A STRUCTURAL PLAN WAS |
| | PROVIDED, BUT AN ARCHITECTURAL TYPE PLAN IS REQUIRED TO |
| | SHOW COMPLIANCE WITH ACCESSIBLE ROUTE AND DECK LAYOUT. |
| | WHICH DIRECTION ARE THE BOARDS INSTALLED AT THE RAMP |
| | TURNS; IT APPEARS THAT THE USER WILL TRAVEL IN BOTH |
| | DIRECTIONS TO MAKE THE TURN, NOT CLEAR HOW BOARDS WILL |
| | COMPLY. |
| | |
| | 7. PROVIDE PLANS FOR THE PROPOSED DECK: FLOOR PLAN, |
| | SECTIONS, DETAIL TO SHOW ELEVATION CHANGE AT DOORS, FBC |
| | 107. |
| | |
| | 8. A VALUE OF $0 WAS PROVIDED FOR THIS REVISION. A |
| | VALUE OF $10K WAS PROVIDED AT TIME OF PERMIT ISSUANCE |
| | FOR A TEMPORARY CONSTRUCTION TRAILER. PROVIDE CONTRACT |
| | AMOUNT, FBC 109. IF AMOUNT EXCEEDS THE AMOUNT IN THE |
| | ICC VALUATION TABLES, A VALUE ADJUSTMENT TO THE TABLES |
| | WILL BE DONE AFTER OCCUPANCY CLASSIFICATION AND |
| | BUILDING TYPE ARE DETERMINED. |
| | |
| | 9. PRIOR TO RESUBMITTING, PLEASE SCHEDULE AN |
| | APPOINTMENT FOR A PRE-SCREEN TO ENSURE THAT ALL |
| | INFORMATION REQUIRED IS PROVIDED. IF THIS IS A CHANGE |
| | OF OCCUPANCY (FROM BUSINESS TO ANOTHER OCCUPANCY), |
| | PLEASE ADVISE. |
| | |
| | 10. ALL THREE REVISIONS INDICATE THAT "DECKING DETAIL" |
| | IS INCLUDED IN SCOPE. CLARIFY. THE DECK WHICH CONNECTS |
| | THE STRUCTURES SHOULD BE INCLUDED ON ONE OF THE |
| | REVISIONS OR BE A SEPARATE PERMIT. |
| | |
| | |
| | |