Plan Review Details - Permit 18040974
Plan Review Stops For Permit 18040974
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-05-08 Cont ID  
Sent By cthroop Date 2018-05-08 Time 14:35 Rev Time 0.00
Received By cthroop Date 2018-05-08 Time 14:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-04-30 Cont ID  
Sent By cthroop Date 2018-04-30 Time 13:02 Rev Time 0.00
Received By cthroop Date 2018-04-30 Time 10:42 Sent To  
Notes
2018-04-30 13:23:18BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DESIGN FLOOD ELEVATION FOR NEW SFR IS 9.17 FT. PER
 NGVD 1929 PER ELEVATION CERTIFICATE DATED 8/8/2017.
 2. STRUCTURAL DRAWING FOR CONCRETE PIER FOR ELEVATOR
 EQUIPMENT IS DESIGNED WITH AN ELEVATION OF 8.53 FT.
 NGVD. LOWEST ELEVATION OF MACHINERY OR EQUIPMENT
 SERVICING THE BUILDING SHALL BE AT OR ABOVE THE DESIGN
 FLOOD ELEVATIUONH OF 9.17 FEET.
 SEE SECTION C2 (E) OF ELEVATION CERTIFICATE.
 3. STRUCTURAL DESIGN OF CONCRETE PIER FOR ELEVATOR HAS
 BEEN DIGITALLY SIGNED. DIGITAL SIGNATURES ARE NOT
 APPROVED FOR PAPER PLANS SUBMITTED FOR REVIEW. PROVIDE
 DESIGN WITH ORIGINAL SIGNATURE AND SEAL OF ENGINEER.
 4. SITE SPECIFIC DESIGN FOR ELEVATOR CAB AND RAILING
 SYSTEM SHALL HAVE ORIGINAL SIGNATURE FROM DESIGN
 PROFESSIONAL.
 5. THERE ARE TWO PLAN SHEETS SUBMITTED FOR REVIEW WITH
 NO NAME OR SIGNATURE OF DESIGNER. STRUCTURAL ENGINEER
 TO SIGN AND SEAL PLANS.
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE,
 DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE
 61G15-23.001.
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-05-08 Cont ID  
Sent By jleahy Date 2018-05-08 Time 15:56 Rev Time 0.00
Received By jleahy Date 2018-05-08 Time 15:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-04-26 Cont ID  
Sent By jleahy Date 2018-04-26 Time 11:15 Rev Time 0.00
Received By jleahy Date 2018-04-26 Time 11:15 Sent To B
Notes
2018-04-26 11:41:01FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NEED TO SHOW BRANCH CIRCUIT SIZE AND BREAKER SIZES
  
 DIAGRAM SHOWING DISCONNECTS AND THEIR LOCATION

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-04-30 Cont ID  
Sent By cthroop Date 2018-04-30 Time 13:23 Rev Time 0.00
Received By cthroop Date 2018-04-20 Time 11:09 Sent To I
Notes
2018-04-23 11:09:57ROUTED TO ELECTRICAL INBOX