| Plan Review Stops For Permit 18040814 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2018-07-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-02 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-02 |
Time |
08:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-06-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-28 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-28 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2018-06-28 08:41:12 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. FROM PREVIOUS REVIEWS: THE PLANS PROVIDED LACK THE | | | TITLE BLOCK FOR THE ENGINEER WHO WILL TAKE | | | RESPONSIBILITY, FS 471. | | | | | | I AM UNABLE TO LOCATE A TITLE BLOCK FOR WAYNE K | | | HELMILA, PE59092 ON THE PLANS. | | | | | | IN ORDER TO AVOID A 4TH REVIEW, I'VE CONTACTED THE | | | ENGINEER DIRECTLY VIA THEIR WEBSITE WITH THE FOLLOWING | | | MESSAGE: | | | | | | ATTN: WAYNE K. HELMILA, PE | | | | | | THIS IS 3RD FAILED REVIEW FOR 1901 S FLAGLER DR; | | | ALUMINUM AWNINGS FOR PALM BEACH DAY ACADEMY, 18040814. | | | | | | THE PLANS STILL LACK A TITLE BLOCK IN ACCORDANCE WITH | | | FS471 AND FAC61G15-23.002. YOU CAN VIEW THE FAC AND FS | | | AT FBPE.ORG. | | | | | | TO AVOID A 4TH PLAN REVIEW CYCLE, PLEASE PREPARE A | | | TITLE BLOCK AND SEND TO ME AS AN ATTACHMENT VIA EMAIL. | | | I WILL ADD THE TITLE BLOCK TO YOUR PLANS. IN THE | | | FUTURE, PLEASE ENSURE THAT YOUR TITLE BLOCK IS INCLUDED | | | ON ALL PLANS. | | | | | | ALTERNATIVELY, YOU MAY REVISE THE PLANS ACCORDINGLY AND | | | RESUBMIT. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-05-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-24 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-24 |
Time |
12:17 |
Sent To |
|
|
| Notes |
| 2018-05-24 12:21:20 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. FROM FIRST REVIEW: THE PLANS PROVIDED ARE NOT SIGNED | | | AND SEALED AND LACK THE TITLE BLOCK FOR THE ENGINEER | | | WHO WILL TAKE RESPONSIBILITY, FS 471. THE CALCULATIONS | | | APPEAR TO INCLUDE THE SAME INFORMATION, BUT IS TOO | | | SMALL TO READ. | | | | | | PROVIDE SIGNED AND SEALED FULL SIZE DRAWINGS, FBC 107. | | | | | | 2ND REVIEW - THE PLAN SIZE PAGES WERE NOW SUBMITTED | | | REDUCED (11X17), LIGHT PLANS SUBMITTED. PLANS ARE | | | DIFFICULT TO READ AS THEY ARE LIGHT AND REDUCED. | | | PROVIDE EASILY READIBLE PLANS. PLANS ARE TO BE OF | | | SUFFICIENT QUALITY TO BE REVIEWED, SCANNED, AND USED | | | FOR INSPECTIONS IN THE FIELD. | | | | | | 2. DELEGATED ENGINEERING IS TO BE REVIEWED BY | | | STRUCTURAL ENGINEER OF RECORD, FAC61G15. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-04-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-28 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-28 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2018-04-28 15:39:46 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. THE PLANS PROVIDED ARE NOT SIGNED AND SEALED AND | | | LACK THE TITLE BLOCK FOR THE ENGINEER WHO WILL TAKE | | | RESPONSIBILITY, FS 471. THE CALCULATIONS APPEAR TO | | | INCLUDE THE SAME INFORMATION, BUT IS TOO SMALL TO READ. | | | | | | PROVIDE SIGNED AND SEALED FULL SIZE DRAWINGS, FBC 107. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-06-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-28 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-11 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2018-06-12 15:51:50 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-05-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-24 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-18 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2018-05-18 14:44:19 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-04-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-28 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-18 |
Time |
10:50 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-06-27 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-06-27 |
Time |
10:25 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2018-06-27 |
Time |
10:17 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-05-21 |
|
|
Cont ID |
|
| Sent By |
mc to es |
Date |
2018-05-21 |
Time |
14:03 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-05-18 |
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-04-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-28 |
Time |
15:39 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-04-25 |
Time |
09:51 |
Sent To |
B |
|
| Notes |
|
|