| Plan Review Stops For Permit 18040739 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-05-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-25 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-25 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2018-05-25 08:33:00 | SEPARATE PERMIT FOR WINDOW AND DOORS | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-05-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-24 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-24 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2018-05-24 12:39:38 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | FROM PREVIOUS LIST: | | | | | | 1. OK | | | | | | 2. TWO COMPLETE SETS OF PRODUCT APPROVALS REQUIRED, | | | PRINTED FULL SIZE. THE PRODUCT APPROVAL IS PARTIAL | | | (DOES NOT HAVE COVER SHEET WHICH INDICATES MIAMIDADE | | | NOA OR FLORIDA STATE PRODUCT APPROVAL) AND PAGES WERE | | | PRINTED HALF SIZE SO ARE NOT LEGIBLE, FBC 107. | | | | | | 2ND REVIEW, NOA IS FOR GLASS. PROVIDE WINDOW PRODUCT | | | APPROVALS. ALSO PROVIDE DOOR PRODUCT APPROVALS IF | | | APPLICABLE. | | | | | | 3. ON THE PRODUCT APPROVAL, INDICATE OPTIONS ELECTED TO | | | SHOW COMPLIANCE WITH THE DESIGN PRESSURE REQUIREMENTS. | | | | | | 2ND REVIEW, NOT ADDRESSED. | | | | | | NEW COMMENT: | | | | | | APPLICANT MAY REMOVE WINDOW REPLACEMENT FROM SCOPE OF | | | THIS PERMIT AND SUBMIT A SEPARATE PERMIT FOR THAT WORK | | | SO THIS PERMIT CAN BE ISSUED. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-13 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-13 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2018-05-13 12:10:50 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC B 1609, SPECIFY COMPONENT AND CLADDING DESIGN | | | PRESSURES AND WIND DESIGN CRITERIA (MINIMUM 170MPH | | | EXPOSURE D). | | | | | | 2. TWO COMPLETE SETS OF PRODUCT APPROVALS REQUIRED, | | | PRINTED FULL SIZE. THE PRODUCT APPROVAL IS PARTIAL | | | (DOES NOT HAVE COVER SHEET WHICH INDICATES MIAMIDADE | | | NOA OR FLORIDA STATE PRODUCT APPROVAL) AND PAGES WERE | | | PRINTED HALF SIZE SO ARE NOT LEGIBLE, FBC 107. | | | | | | 3. ON THE PRODUCT APPROVAL, INDICATE OPTIONS ELECTED TO | | | SHOW COMPLIANCE WITH THE DESIGN PRESSURE REQUIREMENTS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-05-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-05-01 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-05-01 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-04-23 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-04-23 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-04-23 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2018-04-23 11:45:53 | PERMIT # 18040739 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 1) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-05-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-24 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-16 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2018-05-17 13:38:44 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-05-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-05-15 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-17 |
Time |
14:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2018-04-27 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-04-27 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-04-27 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2018-04-27 14:09:49 | NO MECHANICAL PLAN PER PLAN NOTE WILL BE ON SEPARATE | | | PERMIT | | | | | | CHRIS MONTELLO | | | 561-805-6733 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-05-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-05-15 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-05-15 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|