Plan Review Details - Permit 18040726
| Plan Review Stops For Permit 18040726 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-04-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-04-24 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-04-24 |
Time |
11:34 |
Sent To |
Z |
|
| Notes |
| 2018-04-24 13:01:04 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. LIABILITY AND WORKERS COMP. INSURANCE HAS EXPIRED. | | | 2. QUALITY OF PLANS NOT ACCEPTABLE FOR RECORDS | | | MANAGEMENT. | | | 3. CONSTRUCTION DOCUMENTS TO BE SUBMITTED IN TWO OR | | | MORE SETS. | | | | | | FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | | RECORDS MANAGEMENT. | | | | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-04-23 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-04-23 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-04-23 |
Time |
09:56 |
Sent To |
B |
|
| Notes |
| 2018-04-23 11:18:57 | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | ONLY ONE SET OF PLANS AND SPECS SUBMITTED, ALSO PLANS | | | NEED TO BE 1/8" SCALE MINIMUM. TO SMALL TO READ | | | | | | NEED A SHEET SHOWING THE SIGNS THAT ARE TO BE APPLIED | | | TO THIS SYSTEM AND WHERE THEY GO.690.7, 690.7, 690.10, | | | 690.13(B), 690.17(E) 690.31(G)(3), 690.31(G)(4), | | | 690.35(F), 690.56(B), 690.56(C) | | | | | | PLANS SHOW INVERTER FEEDING TWO SEPARATE PANELS, PLEASE | | | EXPLAIN WHAT SMALL SECOND PANEL IS FOR AND IF IT IS | | | EXISTING. HOW DOES THIS WORK? TWO LOADS? | | | | | | NEED TO EXPLAIN HOW BATTERY SYSTEM WILL WORK AND WHAT | | | THE PURPOSE OF BATTERY SYSTEM. DOES IT HAVE AN OUTSIDE | | | BRANCH CIRCUIT FEEDING IT TO CHARGE IT? | | | IF USED FOR STORAGE SEE 690.71 | | | | | | WHAT IS THE FUNCTION OF THE AUTO TRANSFROMER. | | | | | | PLEASE SUBMIT A SIGNED CONTRACTO FOR THE WORK INVOLVED. | | | $3.50 PER WATT IS WHAT WE USE FOR SYSTEMS WITHOUT | | | BATTERY BACKUP OR STORAGE? | | | | | | NEED TO SHOW ACCESS PATHWAYS ON ROOF ON PLAN FIRE CODE | | | 11.12.2.2.2..1 | | | | | | MAIN TO BE GROUPED 690.13(E) CAN NOT TELL FROM DRAWING | | | IF LOAD SIDE MAINS OF INVERTER ARE GROUPED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-04-30 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-04-30 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-04-17 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2018-04-18 13:00:22 | ROUTED TO JLEAHY |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-04-30 |
|
|
Cont ID |
|
| Sent By |
hmtribou |
Date |
2018-04-30 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
hmtribou |
Date |
2018-04-30 |
Time |
07:56 |
Sent To |
I |
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |