| Plan Review Stops For Permit 18040645 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-02-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-02-27 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-02-27 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-01-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-01-09 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-01-08 |
Time |
18:54 |
Sent To |
|
|
| Notes |
| 2019-01-09 16:29:17 | PLAN REVIEW COMMENTS | | | FOUNDATION ONLY PERMIT | | | | | | 3RD REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1- NOT COMPLIED. THE SUBMIT A COPY OF THE LOMR FROM | | | FEMA THAT IS MENTIONED IN YOUR RESPONSE. RESIDENTIAL | | | BUILDINGS LOCATED IN A SPECIAL FLOOD HAZARD AREA ARE | | | NOT ALLOWED TO HAVE BASEMENTS BELOW THE BFE. THE | | | PROPOSED STRUCTURE IS LOCATED IN FLOOD ZONE AE WITH | | | BASE FLOOD ELEVATIONS 6 AND 7. ACCORDING TO CITY | | | ORDINANCE 4729-17 SEC. 18-34 THE FINISH FLOOR ELEVATION | | | NEEDS TO BE TWO FEET (FREEBOARD) ABOVE THE BASE FLOOD | | | ELEVATION. | | | BASEMENT FLOOR NEEDS TO BE RAISED. | | | NOTE: ELEVATION CERTIFICATES ARE REQUIRED. INCLUDING | | | CONSTRUCTION DRAWINGS, DURING CONSTRUCTION AND FINAL. | | | | | | 2- PARTIAL COMPLIANCE. THIS DATA WILL NOT BE REQUIRED | | | IF THE PROPERTY IS REMOVED FROM THE FLOOD HAZARD AREA. | | | PROVIDE ALL THE INFORMATION REQUIRED BY FBC 1603.1.7 | | | FLOOD DESIGN DATA. | | | | | | 3- A) & B) COMPLIED. | | | | | | 4- NOT COMPLIED. PLAN SHEETS 000.1 THRU 000.4 ARE | | | MARKED "PRELIMINARY NOT FOR CONSTRUCTION" AND IT IS | | | STATED THAT THE DOCUMENT IS NOT FOR PERMITS OR OTHER | | | OFFICIAL PURPOSES IN THE TITLE BLOCK. PLEASE REMOVE | | | THIS INFORMATION. ALL PLANS AND CONSTRUCTION DOCUMENTS | | | THAT ARE SUBMITTED FOR PERMIT ARE REQUIRED TO BE SIGNED | | | AND SEALED BY THE ENGINEER OR ARCHITECT THAT PREPARED | | | THEM. FS 471 & 481 | | | | | | 5- A) COMPLIED. | | | | | | B) COMPLIED. | | | | | | 6- NOTED. WILL COMPLY. THE CITY OF WEST PALM BEACH ART | | | IN PUBLIC PLACES ORDINANCE REQUIREMENT THAT APPLIES TO | | | ANY REMODEL OR NEW CONSTRUCTION PROJECT FOR WHICH THE | | | PERMIT APPLICATION WAS SUBMITTED AFTER 7/1/14, AND THE | | | TOTAL PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR | | | GREATER THAN $500,000. PER CITY OF WEST PALM BEACH | | | ORDINANCE NO. 4504-14, AND CITY OF WEST PALM BEACH CODE | | | OF ORDINANCES, ARTICLE V, ART IN PUBLIC PLACES, SECTION | | | 78-123(A) AND SECTION 78-126(A), THE ART ASSESSMENT IS | | | 1% OF THE TOTAL PROJECT CONSTRUCTION COST. | | | | | | 7- NOT COMPLIED. PLEASE COORDINATE WITH RICHARD | | | GATHRIGHT AT [email protected]. THE PROPOSED BUILDING | | | QUALIFIES AS A THRESHOLD BUILDING. A COMPLETED THREHOLD | | | INSPECTION AGREEMENT IS REQUIRED TO BE SUBMITTED AND | | | APPROVED BY THIS OFFICE. I WILL BE HAPPY TO EMAIL A | | | COPY OF THE CITY'S THRESHOLD/SPECIAL INSPECTOR | | | GUIDELINES AND FORMS TO YOU. JUST SEND ME AN EMAIL | | | REQUESTING IT. FBC 110.8 CITY AMENDMENTS. | | | | | | 8- NOT COMPLIED. SEC. 110.8.4 CITY AMENDMENTS: EACH | | | ENFORCEMENT AGENCY SHALL REQUIRE THAT, ON EVERY | | | THRESHOLD BUILDING: SEC. 110.8.4.3 ALL SHORING AND | | | RESHORING PROCEDURES, PLANS AND DETAILS SHALL BE | | | SUBMITTED TO THE ENFORCEMENT AGENCY FOR RECORD KEEPING. | | | EACH SHORING AND RESHORING INSTALLATION SHALL BE | | | SUPERVISED, INSPECTED AND CERTIFIED TO BE IN COMPLIANCE | | | WITH THE SHORING DOCUMENTS BY THE CONTRACTOR . | | | | | | NOT COMPLIED. THIS STATEMENT ONLY APPEARS ON THE | | | ARCHITECTURAL PLANS. PLEASE ADD IT TO THE STRUCTURAL | | | PLANS THAT ARE SIGNED BY THE ENGINEER. THE STATEMENT | | | CAN BE PLACED ON THE STRUCTURAL COVER SHEET S-000. | | | SEC.110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE | | | REQUIRED TO BE SIGNED AND SEALED BY THE ARCHITECT OR | | | ENGINEER OF RECORD CONTAIN A STATEMENT THAT, TO THE | | | BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE | | | PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE | | | MINIMUM BUILDING CODES AND THE APPLICABLE FIRE-SAFETY | | | STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN | | | ACCORDANCE WITH THIS SECTION AND CHAPTER 633. | | | | | | 9- NOTED. WILL COMPLY. | | | | | | 10- NOTED. WILL COMPLY. | | | | | | 11- COMPLIED. | | | | | | 12- NOTED. WILL COMPLY. | | | | | | 13- A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ****NOTE: CHECK FOR COMPLIANCE WITH THE TWO FIRE | | | SERVICE ACCESS ELEVATORS SEC. 403.6.1 FBC. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-11-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-11-08 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-11-07 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2018-11-08 07:35:40 | PLAN REVIEW COMMENTS | | | FOUNDATION ONLY PERMIT | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1- NOT COMPLIED. SUBMIT A COPY OF THE LOMR FROM FEMA | | | THAT IS MENTIONED IN YOUR RESPONSE. RESIDENTIAL | | | BUILDINGS LOCATED IN A SPECIAL FLOOD HAZARD AREA ARE | | | NOT ALLOWED TO HAVE BASEMENTS BELOW THE BFE. THE | | | PROPOSED STRUCTURE IS LOCATED IN FLOOD ZONE AE WITH | | | BASE FLOOD ELEVATIONS 6 AND 7. ACCORDING TO CITY | | | ORDINANCE 4729-17 SEC. 18-34 THE FINISH FLOOR ELEVATION | | | NEEDS TO BE TWO FEET (FREEBOARD) ABOVE THE BASE FLOOD | | | ELEVATION. | | | BASEMENT FLOOR NEEDS TO BE RAISED. | | | NOTE: ELEVATION CERTIFICATES ARE REQUIRED. INCLUDING | | | CONSTRUCTION DRAWINGS, DURING CONSTRUCTION AND FINAL. | | | | | | | | | 2- PARTIAL COMPLIANCE. THIS DATA WILL NOT BE REQUIRED | | | IF THE PROPERTY IS REMOVED FROM THE FLOOD HAZARD AREA. | | | PROVIDE ALL THE INFORMATION REQUIRED BY FBC 1603.1.7 | | | FLOOD DESIGN DATA. | | | | | | | | | 3- A) & B) COMPLIED. | | | | | | 4- PARTIAL COMPLIANCE. THE SITE PLANS ARE REQUIRED | | | MARKED FOR REFERENCE ONLY. ALL PLANS AND CONSTRUCTION | | | DOCUMENTS THAT ARE SUBMITTED FOR PERMIT ARE REQUIRED TO | | | BE SIGNED AND SEALED BY THE ENGINEER OR ARCHITECT THAT | | | PREPARED THEM. FS 471 & 481 | | | | | | 5- A) NOTICE AT RISK, THIS PERMIT IS FOR A FOUNDATION | | | ONLY, PLEASE PROVIDE AN APPENDIX TO THE PERMIT | | | APPLICATION, DESCRIPTION OF WORK, AS TO WHAT WORK IS TO | | | BE ACCOMPLISHED UNDER THIS FOUNDATION PERMIT. | | | SEC.105.13 CITY AMENDMENTS. | | | | | | B) THIS IA A PHASED PERMIT APPLICATION FOR FOUNDATION | | | ONLY. SEC. 105.13 CITY AMENDMENTS. A COMPLETE REVIEW | | | FOR BUILDING CODE COMPLIANCE CAN NOT BE DONE AT THIS | | | TIME. A VERY LIMITED REVIEW WAS DONE ON THE LIFESAFETY | | | PLANS SUBMITTED. INFORMATION ON THE STAIRWAY WAY ACCESS | | | IS NOT VERY CLEAR. ALSO, THE WAY THE TRAVEL DISTANCES | | | FROM THE MOST REMOTE POINTS ARE NOT CLEAR AT THIS | | | POINT. THE EXIT DISCHARGE ON SOME STAIRWAYS IS NOT | | | CLEAR. BASED ON A PRELIMINARY REVIEW OF THE LIFESAFETY | | | PLANS SUBMITTED IT WAS OBSERVED THAT DESIGN | | | PROFESSIONAL IS USING THE TOTAL SIZE OF THE DOORS FOR | | | EGRESS CAPACITY CALCULATIONS. THIS IS INCORRECT. NEED | | | TO USE THE CLEAR WIDTH OPENING OF THE DOOR FOR EGRESS | | | CAPACITY. REVISE ALL CALCULATIONS SHOWN ON ALL PLANS AS | | | REQUIRED. SEE SEC. 1010.1.1 FOR DETERMINATION OF | | | MINIMUM CLEAR WIDTH OF DOOR. COMPLETE REVIEW OF LIFE | | | SAFETY PLANS WILL BE DONE WHEN SUBMITTING THE PLANS FOR | | | THE BUILDING PERMIT. | | | | | | | | | 6- NOTICE ONLY: THE CITY OF WEST PALM BEACH ART IN | | | PUBLIC PLACES ORDINANCE REQUIREMENT THAT APPLIES TO ANY | | | REMODEL OR NEW CONSTRUCTION PROJECT FOR WHICH THE | | | PERMIT APPLICATION WAS SUBMITTED AFTER 7/1/14, AND THE | | | TOTAL PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR | | | GREATER THAN $500,000. PER CITY OF WEST PALM BEACH | | | ORDINANCE NO. 4504-14, AND CITY OF WEST PALM BEACH CODE | | | OF ORDINANCES, ARTICLE V, ART IN PUBLIC PLACES, SECTION | | | 78-123(A) AND SECTION 78-126(A), THE ART ASSESSMENT IS | | | 1% OF THE TOTAL PROJECT CONSTRUCTION COST. | | | | | | 7- THE PROPOSED BUILDING QUALIFIES AS A THRESHOLD | | | BUILDING. A COMPLETED THREHOLD INSPECTION AGREEMENT IS | | | REQUIRED TO BE SUBMITTED AND APPROVED BY THIS OFFICE. I | | | WILL BE HAPPY TO EMAIL A COPY OF THE CITY'S | | | THRESHOLD/SPECIAL INSPECTOR GUIDELINES AND FORMS TO | | | YOU. JUST SEND ME AN EMAIL REQUESTING IT. FBC 110.8 | | | CITY AMENDMENTS. | | | | | | 8- SEC. 110.8.4 CITY AMENDMENTS: EACH ENFORCEMENT | | | AGENCY SHALL REQUIRE THAT, ON EVERY THRESHOLD BUILDING: | | | SEC. 110.8.4.3 ALL SHORING AND RESHORING PROCEDURES, | | | PLANS AND DETAILS SHALL BE | | | SUBMITTED TO THE ENFORCEMENT AGENCY FOR RECORD KEEPING. | | | EACH SHORING AND RESHORING INSTALLATION SHALL BE | | | SUPERVISED, INSPECTED AND CERTIFIED TO BE IN COMPLIANCE | | | WITH THE SHORING DOCUMENTS BY THE CONTRACTOR . | | | | | | SEC.110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE | | | REQUIRED TO BE SIGNED AND SEALED BY THE ARCHITECT OR | | | ENGINEER OF RECORD CONTAIN A STATEMENT THAT, TO THE | | | BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE | | | PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE | | | MINIMUM BUILDING CODES AND THE APPLICABLE FIRE-SAFETY | | | STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN | | | ACCORDANCE WITH THIS SECTION AND CHAPTER 633. | | | | | | NOTE: ALL PLANS SUBMITTED BY ARCHITECT AND ENGINEER | | | NEED THIS STATEMENT. | | | | | | | | | 9- NOTED. WILL COMPLY. | | | | | | 10- NOTED. WILL COMPLY. | | | | | | 11- NOT COMPLIED. I WAS UNABLE TO LOCATE NOTE 11 ON | | | SHEET S-100 AS INDICATED ON THE RESPONSE LETTER. PLEASE | | | PROVIDE COMPLIANCE WITH PROTECTION OF PEDESTRIANS AS | | | REQUIRED BY SEC. 3306.1 FBC. | | | | | | 12- BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 13- A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ****NOTE: CHECK FOR COMPLIANCE WITH THE TWO FIRE | | | SERVICE ACCESS ELEVATORS SEC. 403.6.1 FBC. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-05-23 |
Time |
19:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-05-22 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2018-05-22 11:44:55 | FOUNDATION ONLY BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017). | | | | | | | | | 1- THE PROPOSED STRUCTURE IS LOCATED IN FLOOD ZONE AE | | | WITH BASE FLOOD ELEVATIONS 6 AND 7. ACCORDING TO CITY | | | ORDINANCE 4729-17 SEC. 18-34 THE FINISH FLOOR ELEVATION | | | NEEDS TO BE TWO FEET FREEBOARD ABOVE THE BASE FLOOD | | | ELEVATION. | | | BASEMENT FLOOR NEEDS TO BE RAISED. | | | | | | NOTE: ELEVATION CERTIFICATES ARE REQUIRED. INCLUDING | | | CONSTRUCTION DRAWINGS, DURING CONSTRUCTION AND FINAL. | | | | | | | | | 2- NEW FLOOD MAPS WENT INTO EFFECT ON OCTOBER 5TH 2017. | | | THE NEW MAPS BASED FLOOD ELEVATIONS ARE BASED NAVD | | | 1988. PLANS AND INFORMATION SUBMITTED ARE BASED ON NGVD | | | 1929. NEED TO UPDATE ALL THE INFORMATION SUBMITTED | | | INCLUDING PLANS TO REFERENCE THE CURRENT ADOPTED MAPS. | | | PROVIDE ALL THE INFORMATION REQUIRED BY SEC. 1603.17.7 | | | FBC. | | | | | | | | | 3- A) SHEET S-001: CITY AMENDMENTS SEC. 120.1 REQUIRES | | | TO USE THE ULTIMATE WIND LOAD OF 170 MPH VULT. REVISE | | | SEC. CD-3 AS REQUIRED AND CLARIFY WHY THE NOMINAL WIND | | | LOAD IS 112MPH VASD INSTEAD OF 132MPHVASD? | | | | | | B) CODES AND DESIGN CRITERIA ON SHEET S-001 REFERENCES | | | ACI 530-11. CHAPTER 35 FBC REFERENCES ACI 530-13. | | | UPDATE AS REQUIRED. | | | | | | 4- PROVIDE SURVEY SHOWING THE PROPOSED STRUCTURE. SEC. | | | 107.3.5 CITY AMENDMENTS. | | | | | | 5- A) NOTICE AT RISK, THIS PERMIT IS FOR A FOUNDATION | | | ONLY, PLEASE PROVIDE AN APPENDIX TO THE PERMIT | | | APPLICATION, DESCRIPTION OF WORK, AS TO WHAT WORK IS TO | | | BE ACCOMPLISHED UNDER THIS FOUNDATION PERMIT. | | | SEC.105.13 CITY AMENDMENTS. | | | | | | B) THIS IA A PHASED PERMIT APPLICATION FOR FOUNDATION | | | ONLY. SEC. 105.13 CITY AMENDMENTS. A THOUGHTFULLY | | | REVIEW FOR BUILDING CODE COMPLIANCE CAN NOT BE DONE AT | | | THIS TIME. A VERY LIMITED REVIEW WAS DONE ON THE | | | LIFESAFETY PLANS SUBMITTED. INFORMATION ON THE STAIRWAY | | | WAY ACCESS IS NO VERY CLEAR. ALSO, THE WAY THE TRAVEL | | | DISTANCES FROM THE MOST REMOTE POINTS ARE NOT CLEAR AT | | | HIS POINT. THE EXIT DISCHARGE ON SOME STAIRWAYS IS NOT | | | CLEAR. BASED ON A PRELIMINARY REVIEW OF THE LIFESAFETY | | | PLANS SUBMITTED IT WAS OBSERVED THAT DESIGN | | | PROFESSIONAL IS USING THE TOTAL SIZE OF THE DOORS FOR | | | EGRESS CAPACITY CALCULATIONS. THIS IS INCORRECT. NEED | | | TO USE THE CLEAR WIDTH OPENING OF THE DOOR FOR EGRESS | | | CAPACITY. REVISE ALL CALCULATIONS SHOWN ON ALL PLANS AS | | | REQUIRED. SEE SEC. 1010.1.1 FOR DETERMINATION OF | | | MINIMUM CLEAR WIDTH OF DOOR. COMPLETE REVIEW OF LIFE | | | SAFETY PLANS WILL DONE WHEN SUBMITTING THE PLANS FOR | | | THE BUILDING PERMIT. | | | | | | | | | NOTE: A FOUNDATION PERMIT MAY NOT BE ISSUED UNTIL A | | | BUILDING PERMIT APPLICATION IS SUBMITTED FOR THE | | | CONSTRUCTION OF THE BUILDING. | | | | | | | | | 6- NOTICE ONLY: THE CITY OF WEST PALM BEACH ART IN | | | PUBLIC PLACES ORDINANCE REQUIREMENT THAT APPLIES TO ANY | | | REMODEL OR NEW CONSTRUCTION PROJECT FOR WHICH THE | | | PERMIT APPLICATION WAS SUBMITTED AFTER 7/1/14, AND THE | | | TOTAL PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR | | | GREATER THAN $500,000. PER CITY OF WEST PALM BEACH | | | ORDINANCE NO. 4504-14, AND CITY OF WEST PALM BEACH CODE | | | OF ORDINANCES, ARTICLE V, ART IN PUBLIC PLACES, SECTION | | | 78-123(A) AND SECTION 78-126(A), THE ART ASSESSMENT IS | | | 1% OF THE TOTAL PROJECT CONSTRUCTION COST. | | | | | | | | | 7- THE PROPOSED BUILDING QUALIFIES AS A THRESHOLD | | | BUILDING. SPECIAL INSPECTOR IS REQUIRED. CONTACT JULIO | | | GOMEZ (561)805-6712 FOR MORE INFORMATION REGARDING | | | SPECIAL INSPECTOR REQUIREMENTS AND APPROVAL. SEC. 110.8 | | | CITY AMENDMENTS. | | | | | | 8- SEC. 110.8.4 CITY AMENDMENTS: EACH ENFORCEMENT | | | AGENCY SHALL REQUIRE THAT, ON EVERY THRESHOLD BUILDING: | | | | | | SEC. 110.8.4.3 ALL SHORING AND RESHORING PROCEDURES, | | | PLANS AND DETAILS SHALL BE | | | SUBMITTED TO THE ENFORCEMENT AGENCY FOR RECORD KEEPING. | | | EACH SHORING AND RESHORING | | | INSTALLATION SHALL BE SUPERVISED, INSPECTED AND | | | CERTIFIED TO BE IN COMPLIANCE WITH THE | | | SHORING DOCUMENTS BY THE CONTRACTOR . | | | | | | 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED | | | TO BE SIGNED AND SEALED | | | BY THE ARCHITECT OR ENGINEER OF RECORD CONTAIN A | | | STATEMENT THAT, TO THE BEST OF THE | | | ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND | | | SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE | | | FIRE-SAFETY STANDARDS AS | | | DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH | | | THIS SECTION AND CHAPTER 633. | | | | | | NOTE: ALL PLANS SUBMITTED BY ARCHITECT AND ENGINEER | | | NEED THIS STATEMENT. | | | | | | | | | 9- FOR DIGITAL PLANS, AFTER PERMIT APPROVAL PLEASE | | | E-MAIL THE PERMIT LIBRARIAN FOR PROPER PROCESSING. | | | SEC. 107.2.1.3 CITY AMENDMENTS. | | | | | | 10- PLEASE CALL THE CITY OF WEST PALM BEACH'S AUTOMATED | | | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR | | | IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE | | | INSPECTIONS. | | | | | | 11-PLEASE PROVIDE COMPLIANCE WITH PROTECTION OF | | | PEDESTRIANS AS REQUIRED BY SEC. 3306.1 FBC. | | | | | | 12-BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 13- A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | | | | ****NOTE: CHECK FOR COMPLIANCE WITH THE TWO FIRE | | | SERVICE ACCESS ELEVATORS SEC. 403.6.1 FBC. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-10-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-03 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-03 |
Time |
15:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-05-06 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-05-06 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-05-01 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2018-05-06 09:11:44 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30 | | | 2. PROVIDE LOAD CALCULATION FOR SERVICE TO CONFIRM | | | CAPACITY OF SERVICE AND FEEDERS IS ADEQUATE. NEC 215.2, | | | 220, 408.30 | | | 3. PLAN PROVIDED STATES THAT THE PLAN IS NOT FOR | | | CONSTRUCTION. PROVIDE CORRECTION. WPB FBC 107.1, | | | 107.2.1, 107.3.5 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2018-12-28 |
|
|
Cont ID |
|
| Sent By |
RRossano |
Date |
2018-12-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2018-12-28 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2018-11-05 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2018-11-05 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2018-11-05 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-02 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-02 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2018-05-02 16:34:56 | CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT | | | APPLICATION | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | | | | ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE | | | | | | MAIN PHONE: (561) 822-1200 | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2018-12-12 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-12-12 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-12-12 |
Time |
10:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-09-26 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-09-26 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-09-26 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2018-09-26 11:02:06 | PERMIT # 18040645 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | APPROVED WITH COMMENTS | | | | | | 1) PERMIT AND APPROVAL IS FOR FOUNDATION ONLY. | | | | | | 2) PER NFPA 241 SECTION 8.7.2.3, WHERE UNDERGROUND | | | WATER MAINS AND HYDRANTS ARE TO BE PROVIDED, THEY SHALL | | | BE INSTALLED, COMPLETED, AND IN SERVICE PRIOR TO | | | CONSTRUCTION WORK. | | | | | | 3) SEPARATE PLANS AND PERMITS NEEDED FOR PRIVATE | | | UNDERGROUND FIRE LINE AND FIRE HYDRANTS. | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-04-20 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-04-20 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-04-20 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2018-04-20 09:41:39 | PERMIT # 18040645 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | APPROVED WITH COMMENTS: | | | | | | 1) PER NFPA 241 SECTION 8.7.2.3, WHERE UNDERGROUND | | | WATER MAINS AND HYDRANTS ARE TO BE PROVIDED, THEY SHALL | | | BE INSTALLED, COMPLETED, AND IN SERVICE PRIOR TO | | | CONSTRUCTION WORK. | | | | | | 2) SEPARATE PLANS AND PERMITS NEEDED FOR PRIVATE | | | INSTALLATION AND/OR MODIFICATION OF THE UNDERGROUND | | | FIRE LINE AND FIRE HYDRANTS. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4751 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-03-07 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-03-07 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-02-10 |
Time |
07:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-01-22 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-01-22 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-12-11 |
Time |
12:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-11-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-11-17 |
Time |
11:39 |
Rev Time |
|
| Received By |
shill |
Date |
2018-09-24 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-04 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-06-04 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-04-19 |
Time |
16:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2019-01-11 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-01-10 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-01-08 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2019-01-10 16:40:31 | PLANS STAMPED NO FEE DUE. AWAITING COPY OF BACKUP IN | | | LIEU OF RECEIPT AS NO RECEIPT IS PRODUCED WHEN NO MONEY | | | DUE. SAK | | 2019-01-10 15:49:49 | PER IMPACT FEE OFFICE, NO FEES OWED. LEM | | 2019-01-08 13:46:36 | 1/8/19 SENT EMAIL TO IMPACT FEE OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2018-12-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-20 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-20 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2018-12-20 15:29:03 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-05-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-05-24 |
Time |
18:55 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-05-24 |
Time |
18:23 |
Sent To |
|
|
| Notes |
| 2018-05-24 18:56:11 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
P |
Date |
2019-02-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-02-27 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-02-27 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2019-02-27 15:34:08 | LETTER OF MAP REVISION BASED ON FILL (LOMR-F) DATED | | | JANURARY 10, 2019, CASE NUMBER 19-04-1248A. PROPERTY | | | AROUND BUILDING WAS REMOVED FROM THE SFHA AND CHANGED | | | TO FLOOD ZONE X. |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2018-11-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-11-08 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-11-08 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2018-11-08 10:53:22 | ELEVATION CERTIFICATE OR LOMR IS REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-10-18 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-10-18 |
Time |
16:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-05-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-05-21 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-05-21 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2018-05-21 16:35:55 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE ISOMETRIC DRAWINGS FOR UNDERGROUND PIPING | | | ONLY TO INCLUDE DFU LOAD ON THE SANITARY AND THE SQFT | | | ON THE STORM DRAIN PIPING ALSO ANY COND. AND WATER | | | PIPING THAT IS UNDERGROUND. PER WPB AMEND TO FBC | | | 107.3.5.1.3(13) | | | | | | 2. THE PLAN SHEET IS NOTED NOT FOR CONSTRUCTION | | | PRELIMINARY NOT FOR PERMIT PLEASE REMOVE NOTE AND STATE | | | FOR FOUNDATION ONLY. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-21 |
Time |
18:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-21 |
Time |
18:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2018-11-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-11-06 |
Time |
06:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-11-06 |
Time |
06:23 |
Sent To |
|
|
| Notes |
| 2018-10-03 13:57:29 | 1. DIGITAL SIGNATURES/SEALS ARE IN ACCORDANCE WITH FS | | | 471, FS 481. | | | LAST PLAN REVIEWER SHOULD ENTER STATUS OF PASSED IF ALL | | | OTHER REVIEWS PASS. IF ANY DISCIPLINE FAILS, A STATUS | | | OF FAIL SHOULD BE ENTERED SO THAT NEW SHEETS SUBMITTED | | | IN THE NEXT REVIEW CYCLE CAN BE REVIEWED FOR SIGNATURE. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2018-05-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-24 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-24 |
Time |
17:47 |
Sent To |
|
|
| Notes |
| 2018-05-24 17:48:19 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE IN ACCORDANCE WITH FS | | | 471, FS 481. NEW SHEETS SUBMITTED IN THE NEXT REVIEW | | | CYCLE REQUIRE REVIEW. | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-01-14 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-01-14 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2019-01-14 09:44:12 | THORNTON TOMASETTI (954) 903-9300 | | | 101 NE 3RD AVE, SUITE 1170, FORT LAUDERDALE, FL 33301 | | | [email protected] | | | ERIC DAVID SEARCH (786) 385-1518 | | | PE 54984 | | | SI 7018775 |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2018-11-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-11-08 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-11-08 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2018-11-08 10:51:06 | THRESHOLD INSPECTION AGREEMENT AND INSPECTION PLAN IS | | | REQUIRED. FBC 110.8 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2019-03-07 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-03-07 |
Time |
09:01 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2019-03-07 |
Time |
09:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-01-22 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-01-22 |
Time |
09:55 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2019-01-22 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2019-01-22 10:24:29 | PASSED W/PROVISO | | | | | | 1) THE DEVELOPER SHALL PERFORM A "CONDITION SURVEY" OF | | | THE ADJOINING PROPERTIES PRIOR TO THE COMMENCEMENT OF | | | ANY CONSTRUCTION ACTIVITIES. THE DEVELOPER SHALL | | | CONFORM TO THE APPROPRIATE INDUSTRY STANDARDS APPROVED | | | BY THE CITY'S CONSTRUCTION SERVICES DEPARTMENT IN | | | MONITORING THE VIBRATION EFFECTS ON THE ADJOINING | | | PROPERTIES; THIS SHALL INCLUDE, BUT IS NOT LIMITED TO, | | | THE PLACEMENT OF SEISMIC METERS, INSPECTIONS, AND | | | SIMILAR ACTIVITIES. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-11-16 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-11-16 |
Time |
15:21 |
Rev Time |
2.00 |
| Received By |
eschneid |
Date |
2018-11-09 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2018-11-16 16:30:16 | FAILED | | | | | | PLEASE PROVIDE WRITTEN RESPONSES. | | | | | | 1) THE MINOR AMENDMENT FOR THE CHANGES TO THE PLANS HAS | | | NOT BEEN APPROVED. THE OUTSTANDING COMMENTS RELATING TO | | | THE FOUNDATION ARE LISTED BELOW: | | | | | | A. ZONING - UPON REVIEW OF THE REVISED PLANS WHICH | | | INCLUDE THE EGRESS PATHWAY, STAFF NOTED THAT THE | | | RETAINING WALL LOCATION IS SHOWN FURTHER FROM THE WEST | | | PROPERTY LINE ON THE ARCHITECTURAL SITE PLAN AND THE | | | LANDSCAPE PLAN THAN IT IS SHOWN ON THE CIVIL PLANS. | | | WHICH RETAINING WALL LOCATION IS CORRECT? - THE | | | LOCATION OF THIS RETAINING WALL AFFECTS THE LOCATION OF | | | THE WALLS FOR THE BELOW GRADE PARKING. | | | | | | B. BUILDING - APPLICANT THOUGHT THEY WOULD HAVE THE | | | LOMR LETTER BY OCTOBER 8. AS OF TODAY, THEY HAVE NOT | | | ADVISED THAT IT WAS ISSUED (AND IT IS NOT ON THE FEMA | | | WEBSITE). I'VE ASKED FOR AN UPDATE TWICE SO I DO NOT | | | THINK THEY HAVE AN ANSWER FROM FEMA YET. - NOTE: THE | | | LOMR WAS SUBSEQUENTLY RECEIVED BY THE CITY AND WAS NOT | | | APPROVED. | | | | | | 2) SHEET S-100 DOES NOT MATCH THE FOUNDATION WALL | | | LAYOUT SHOWN ON SHEETS S-100A. THE MATCH LINE BETWEEN | | | SHEETS S-100A AND S-100B DO NOT ACTUALLY MATCH ALONG | | | THE SOUTH PORTION OF THE PLANS. THIS IS THE SAME ISSUE | | | IDENTIFIED IN COMMENT NO. 1 ABOVE. THIS SEEMS TO BE AN | | | ISSUE ON ALL THE PLANS UPLOADED ON 4/19/2018. | | | | | | 3) REVISED CIVIL PLANS WERE NOT UPLOADED WITH THE LAST | | | PERMIT RESUBMITTAL AND THUS THESE ARE NOT THE MOST | | | RECENT PLANS REVIEWED AS PART OF THE MINOR AMENDMENT. | | | | | | CONDITIONS FOR WHEN PERMIT IS ISSUED: | | | | | | 1) THE DEVELOPER SHALL PERFORM A "CONDITION SURVEY" OF | | | THE ADJOINING PROPERTIES PRIOR TO THE COMMENCEMENT OF | | | ANY CONSTRUCTION ACTIVITIES. THE DEVELOPER SHALL | | | CONFORM TO THE APPROPRIATE INDUSTRY STANDARDS APPROVED | | | BY THE CITY'S CONSTRUCTION SERVICES DEPARTMENT IN | | | MONITORING THE VIBRATION EFFECTS ON THE ADJOINING | | | PROPERTIES; THIS SHALL INCLUDE, BUT IS NOT LIMITED TO, | | | THE PLACEMENT OF SEISMIC METERS, INSPECTIONS, AND | | | SIMILAR ACTIVITIES. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-06-04 |
|
|
Cont ID |
|
| Sent By |
ES |
Date |
2018-06-04 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2018-06-04 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2018-06-04 13:20:15 | FAILED | | | | | | PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS: | | | | | | 1) ORDINANCE NO. 4245-09 CONTAINS THE LATEST | | | DEVELOPMENT REGULATIONS FOR THE 1515 SITE APPROVAL. | | | PLEASE ADDRESS THE FOLLOWING REQUIREMENTS: | | | | | | A. RECORD, IN THE PUBLIC RECORDS OF PALM BEACH COUNTY, | | | AN ABANDONMENT OF ALL EASEMENTS THAT CONFLICT WITH THE | | | BUILDING, AS WELL AS ANY OTHER UNNECESSARY EASEMENTS. | | | | | | B. VERIFY THAT THE PROJECT SHALL BE CONSTRUCTED USING | | | AN AUGURED PILING OR SIMILAR PILING SYSTEM. | | | | | | C. THE DEVELOPER SHALL PERFORM A "CONDITION SURVEY" OF | | | THE ADJOINING PROPERTIES PRIOR TO THE COMMENCEMENT OF | | | ANY CONSTRUCTION ACTIVITIES. THE DEVELOPER SHALL | | | CONFORM TO THE APPROPRIATE INDUSTRY STANDARDS APPROVED | | | BY THE CITY'S CONSTRUCTION SERVICES DEPARTMENT IN | | | MONITORING THE VIBRATION EFFECTS ON THE ADJOINING | | | PROPERTIES; THIS SHALL INCLUDE, BUT IS NOT LIMITED TO, | | | THE PLACEMENT OF SEISMIC METERS, INSPECTIONS, AND | | | SIMILAR ACTIVITIES. | | | | | | D. REGISTER THE PROJECT WITH THE U.S. GREEN BUILDING | | | COUNCIL. | | | | | | 2) PROVIDE VERIFICATION THAT THE FOLLOWING ITEMS FROM | | | THE MAY 11, 2017 MINOR AMENDMENT APPROVAL LETTER, HAVE | | | BEEN MET: | | | | | | A. IF THE GARAGE IS REQUIRED TO BE VENTED, THE | | | EQUIPMENT MAY NOT BE LOCATED ON A FACADE ADJACENT TO | | | THE NEIGHBORING STRUCTURES OR RIGHTS-OF-WAY AND MUST | | | NOT VENT FUMES OR DIRECT NOISE TOWARD THE NEIGHBORING | | | STRUCTURES OR RIGHTS-OF-WAY. | | | | | | B. PRIOR TO THE ISSUANCE OF PERMITS FOR THE PROJECT, | | | THE METHOD FOR CONTROLLING GROUNDWATER FROM ENTERING | | | THE SUBTERRANEAN PARKING GARAGE AND HOW GROUNDWATER | | | WILL BE DISCHARGED FROM THE SITE ARE TO BE APPROVED BY | | | THE CITY'S ENGINEERING SERVICES DEPARTMENT. | | | | | | C. DRAINAGE CALCULATIONS THAT ACCOUNT FOR SEA LEVEL | | | RISE IMPACTS ON THE ON-SITE STORMWATER SYSTEM SHALL BE | | | SUBMITTED WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | D. IN THE ENGINEERING PERMIT PLANS, SHOW CONFLICT | | | INFORMATION (BOTTOM AND TOP OF CROSSING PIPES) AT THE | | | CONFLICT POINTS OF THE PROPOSED WATER AND SANITARY | | | SEWER PIPES WITH THE EXISTING AND PROPOSED STORM DRAINS | | | JUST TO THE NORTH OF THE BUILDING AND INSIDE THE | | | PROPERTY. | | | | | | E. THE ENGINEERING PERMIT PLANS SHALL SHOW THE CITY'S | | | "POINT-OF-SERVICE" MANHOLE WITHIN THE CITY'S | | | RIGHT-OF-WAY. | | | | | | F. THE ENGINEERING PERMIT PLANS SHALL SHOW THE "FIRE | | | POINT-OF-SERVICE" PER 2016 NFPA 24, FROM THE CONNECTION | | | POINT OF THE PROPOSED FIRE LINE TO THE EXISTING WATER | | | MAIN LOCATED WITHIN THE CITY'S RIGHT-OF-WAY I.E. WHERE | | | TAPPING SLEEVE AND VALVES IS SHOWN TO BE FOR BOTH SOUTH | | | FLAGLER DR. AND ARKONA CT. | | | | | | G. THE FINAL WATER AND SEWER PLANS SHALL INCLUDE A NOTE | | | STATING, "ALL BACKFLOW DEVICES MUST BE LEAD FREE." | | | | | | 3) THE PLANS HAVE CHANGED FROM WHAT WAS APPROVED BY THE | | | MAY 11, 2017 MINOR AMENDMENT. THESE CHANGES INCLUDE AN | | | ENLARGED BASEMENT PARKING, A REWORKED ENTRY COURT AND A | | | DIFFERENT POOL DECK LAYOUT. STAFF NEEDS TO REVIEW THE | | | ENTIRE PACKAGE AS PART OF A MINOR AMENDMENT PRIOR TO | | | ISSUING THE APPROVAL OF THE FOUNDATION PERMIT TO MAKE | | | SURE EVERYTHING MEETS THE APPROVAL DOCUMENTS AS WELL AS | | | THE CODE REQUIREMENTS, AND THUS THE FOUNDATION CAN BE | | | BUILT AS SHOWN. ZONING STAFF HAS NOTED THAT THERE IS A | | | DRIVE AISLE SHOWN AT 23 FEET IN WIDTH, WHICH IS LESS | | | THAN THE REQUIRED 24 FOOT MINIMUM. A FULL REVIEW WILL | | | BE DONE AS PART OF THE MINOR AMENDMENT. | | | | | | 4) THE LIFE SAFETY AND THE SITE PLAN SHOW THE GARAGE AT | | | 8 FEET 7 INCHES, WHILE SHEET C.5.00 SHOWS THE SAME AREA | | | AT 9.58 NGVD. PLEASE CLARIFY. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|