| Plan Review Stops For Permit 18040359 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-01-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-03 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-03 |
Time |
13:16 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-10-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-10-19 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-10-19 |
Time |
10:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-04-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-30 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-30 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2018-04-30 10:47:23 | ****PROVISOS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. PLANS REFERENCE INCORRECT CODE BASED ON APPLICATION | | | DATE; REVISE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-12-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-12-27 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-12-27 |
Time |
07:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-09-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-25 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-25 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2018-09-25 16:28:55 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED BY PERSON | | | RESPONSIBLE FOR DESIGN. FS 471.003(2)(H); 471.025; WPB | | | FBC 107.2.1, 107.3.5 9 (ELECTRICAL PLAN IS REQUIRED TO | | | BE SIGNED BY PERSON RESPONSIBLE FOR THE DESIGN. PROVIDE | | | CORRECTION. FS 481.229; WPB FBC 107.2.1, 107.3.5.1.2) | | | 2. CORRECTED. | | | 3. CORRECTED. | | | | | | NEW COMMENT: | | | | | | 4. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. IT | | | APPEARS THE ELECTRICAL IS NOT INCLUDED IN THE CONTRACT | | | PROVIDED. FBC 109.3 | | | 5. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE | | | E3703.4, E3901.6 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-04-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-04-27 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-04-27 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2018-04-27 15:19:35 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED BY PERSON | | | RESPONSIBLE FOR DESIGN. FS 471.003(2)(H); 471.025; WPB | | | FBC 107.2.1, 107.3.5 | | | 2. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE | | | EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC | | | RE R314.3, R315.1; WPB FBC 107.2.1 | | | 3. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; WPB FBC | | | 107.3.5; FBC RE E3706.2, E3902 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-01-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-01-07 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-12-20 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-10-19 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-09-11 |
Time |
15:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-04-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-30 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-09 |
Time |
11:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2018-10-11 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-10-11 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-10-11 |
Time |
13:43 |
Sent To |
B |
|
| Notes |
| 2018-10-11 13:45:52 | NO MECHANICAL WORK PER SCOPE |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-04-25 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-04-25 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-04-25 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2018-04-25 14:00:31 | MECHANICAL PLAN REVIEW FAIL | | | | | | NEED EXHAUST FAN | | | | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | TABLE M1507.4 | | | | | | MINIMUM REQUIRED LOCAL EXHAUST RATES FOR ONE- AND | | | TWO-FAMILY DWELLINGS | | | | | | BATHROOMS-TOILET ROOMS | | | MECHANICAL EXHAUST CAPACITY OF 50 CFM | | | INTERMITTENT OR 20 CFM CONTINUOUS | | | | | | CHRIS MONTELLO | | | 561-805-6733 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-01-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-03 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-03 |
Time |
13:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-03 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-10-03 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-10-03 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2018-10-03 15:04:34 | 10/03/18 REVIEWED FOR CODE COMPLIANCE | | | (PLUMBING/BACKFLOW) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-04-18 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-04-18 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-04-18 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2018-04-18 07:28:10 | 04/18/2018 1ST PLUMBING REVIEW**DENIED** | | | | | | 1) PROVIDE SOURCE OF HOT WATER WITH PIPE SIZING. FBC | | | 107.2.1 | | | | | | 2) SHT A-1 LIST APPLICABLE CODE AS 2014 5TH ED. THE | | | CODE IN EFFECT IS THE 2017 6TH ED. | | | | | | 3) SHOW HOW YOU INTENT TO PROVIDE ACCESS TO WASHING | | | MACHINE SHUT OFF VALVES. FBC 606.3 | | | | | | | | | TIM HUNT | | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | 561-805-6695 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-01-07 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-01-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-01-07 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-01-07 15:21:27 | INTERIOR MODIFICATIONS ONLY. NO CHANGES TO THE | | | EXTERIOR. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2018-09-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2018-09-18 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-09-18 13:58:26 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) REVISED PLANS HAVE NOT BEEN SIGNED AND SEALED. | | | PLANS MUST BE SIGNED, DATED AND SEALED BY A FLORIDA | | | REGISTERED ARCHITECT. | | | | | | NOTES: | | | | | | * INTERIOR CHANGES ONLY. | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * ZONE: SF14-C2 | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-04-23 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2018-04-23 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2018-04-23 |
Time |
10:50 |
Sent To |
|
|
| Notes |
|
|