Plan Review Details - Permit 18040253
| Plan Review Stops For Permit 18040253 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
N |
Date |
2018-06-19 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-06-19 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-06-19 |
Time |
11:42 |
Sent To |
FIRE |
|
| Notes |
| 2018-06-19 11:46:21 | 1ST REVIEW: FBC 2017 6TH ED. RESIDENTIAL | | | | | | EXEMPT PER FBC 102.2 TEMPORARY TRAILER & BUILDING, | | | SHIPPING CONTAINER, USED EXCLUSIVELY FOR CONSTRUCTION | | | PURPOSES LIMITED TO SIX MONTHS IN FROM PERMIT ISSUANCE | | | DATE. | | | | | | | | | STEVEN KENNEDY, CBO | | | ASSISTANT BUILDING OFFICIAL | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-04-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-28 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-28 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2018-04-28 10:27:44 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. NO PLANS WERE SUBMITTED, ONLY A SITE PLAN. | | | | | | THE APPLICATION IS FOR "OFFICE RENTAL TRAILER", SITE | | | PLAN SHOWS "JOB TRAILER". PLEASE SEE CITY OF WEST PALM | | | BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE 2017 | | | 102.2(D), EXEMPTION TO FLORIDA BUILDING CODE | | | REQUIREMENTS ARE "TEMPORARY BUILDINGS OR SHEDS USED | | | EXCLUSIVELY FOR CONSTRUCTION PURPOSES." EITHER REVISE | | | THE PERMIT APPLICATION WORK DESCRIPTON (BOX 5) AND THE | | | SITE PLAN ACCORDINGLY, OR PROVIDE PLANS SHOWING | | | COMPLIANCE WITH THE FLORIDA BUILDING CODE. | | | | | | 2. SCOPE NOT CLEAR. THE APPLICATION APPEARS TO BE FOR | | | TWO TRAILERS. THE SITE PLAN APPEARS TO SHOW MORE THAN | | | TWO TRAILERS. REVISE PLAN TO CLARIFY WHICH TRAILERS ARE | | | COVERED UNDER THIS APPLICATION. | | | | | | 3. PERMIT APPLICATION LACKS AN ADDRESS. A MASTER NUMBER | | | WAS PROVIDED, BUT THE MASTER REFERENCED IS FOR A | | | PROJECT ON A DIFFERENT PARCEL. PROVIDE AN APPLICATION | | | WHICH INCLUDES THE CORRECT ADDRESS FOR PROPOSED | | | TRAILER. | | | | | | 4. THE PROPOSED TRAILERS ARE LOCATED IN A SPECIAL FLOOD | | | HAZARD AREA. TWO DIFFERENT BASE FLOOD ELEVATIONS AFFECT | | | THIS PARCEL. PLANS SUBMITTED ARE TO SHOW COMPLIANCE | | | WITH CITY OF WEST PALM BEACH ORDINANCE 4729-17, CITY OF | | | WEST PALM BEACH MUNICIPAL CODE 18-280(B) WHICH STATES | | | THAT BUILDINGS OR STRUCTURES EXEMPT FROM FLORIDA | | | BUILDING CODE SHALL COMPLY WITH THIS ORDINANCE/CODE, | | | WHICH REQUIRES A 2' FREEBOARD (SEC 18-34B). | | | | | | THIS PARCEL HAS A 6' BFE PORTION AND A 7' BFE PORTION, | | | SO INCLUDING FREEBOARD ELEVATION IS TO BE 8' OR 9' | | | NAVD88. REVISE PLAN TO SHOW PROPOSED ELEVATION OF | | | FINISHED FLOOR. IF 8' NAVD88 IS PROPOSED, REVISE PLAN | | | TO INCLUDE LOCATION OF THE FLOOD ZONE LINE. ALSO NOTE | | | THAT THE FLOOD INSURANCE STUDY MAY BE UTILIZED IN LIEU | | | OF THE FLOOD INSURANCE RATE MAP. | | | | | | 5. IF THE PROPOSED TRAILERS ARE ELEVATED WITH AN | | | ELEVATED SUPPORTING STRUCTURE RATHER THAN FILL, PROVIDE | | | A STRUCTURAL DETAIL SHOWING COMPLIANCE WITH FBC B 1622, | | | RESISTANCE TO FLOOD LOADS. | | | | | | 6. VALUE ON THE APPLICATION SHOULD INCLUDE A REASONABLE | | | VALUE - THE RENTAL FEE, INSTALLATION FEE, OR ANOTHER | | | **REASONABLE** VALUATION, FBC 109. VALUE CANNOT BE $0. | | | | | | 7. APPLICANT INDICATED THAT HE WOULD LIKE TO HAVE THE | | | PROPOSED TRAILERS POWERED BY GENERATOR RATHER THAN | | | ELECTRICITY AS SHOWN ON THE PLAN. PLEASE CONTACT | | | [email protected] (JAKE LEAHY) TO DISCUSS THE DOCUMENTS | | | REQUIRED. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2018-06-19 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-06-19 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-06-19 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2018-06-19 11:47:29 | ELECTRIC WILL BE BY SEPARATE SUBMITTAL AND PERMIT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-04-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-04-30 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-04-30 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2018-04-30 08:28:42 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | | SEALED BY A LICENSED DESIGN PROFESSIONAL OR THE | | | ELECTRICAL CONTRACTOR QUALIFIER. INCLUDE RISER DIAGRAM | | | OF SERVICE AND FEED TO TRAILER. INCLUDE LOAD | | | CALCULATION FOR TRAILER. FS 471.003(2)(H); 471.025; WPB | | | FBC 107.2.1, 107.3.5 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2018-06-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-06-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-06-19 |
Time |
12:56 |
Sent To |
I |
|
| Notes |
| 2018-06-19 13:26:01 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE PREVIOUS COMMENTS SUBMITTED BY FIRE WERE NOT | | | ADDRESSED. | | | | | | 1) THERE IS INSUFFICIENT DETAIL TO DETERMINE COMPLIANCE | | | WITH NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, | | | ALTERATION, AND DEMOLITION OPERATIONS, 2013 EDITION | | | | | | | | | PER NFPA 241, 4.2 TEMPORARY OFFICES AND SHEDS; TABLE | | | 4.2.1 SEPARATION DISTANCES, FIRE SPRINKLERS ARE | | | REQUIRED IN EACH TRAILER. | | | 4.2.1* SEPARATION DISTANCES BETWEEN BUILDINGS UNDER | | | CONSTRUCTION AND CONSTRUCTION-RELATED STRUCTURES, SUCH | | | AS TEMPORARY OFFICES, TRAILERS, SHEDS, AND OTHER | | | FACILITIES FOR THE STORAGE OF TOOLS AND MATERIALS | | | HAVING COMBUSTIBLE CONSTRUCTION OR CONTENTS, SHALL BE | | | IN ACCORDANCE WITH TABLE 4.2.1. | | | | | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | | | | NOTES: | | | (1) WHERE THE SEPARATION DISTANCE BETWEEN TEMPORARY | | | STRUCTURES IS LESS THAN THE MINIMUM SEPARATION | | | DISTANCE, THEN THE EXPOSING WALL LENGTH SHALL BE | | | CONSIDERED TO BE THE SUM OF THE INDIVIDUAL EXPOSING | | | WALL LENGTHS OF THE TEMPORARY STRUCTURES. | | | (2) A 75 PERCENT REDUCTION IN SEPARATION DISTANCES | | | SHALL BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | (3) THE SEPARATION DISTANCES APPLY TO SINGLE-LEVEL | | | STRUCTURES ONLY. THIS TABLE DOES NOT APPLY TO | | | MULTILEVEL, UNSPRINKLERED STRUCTURES. A LEVEL, WHERE | | | APPLYING THIS TABLE, IS 3600 MM (144 IN.). | | | | | | 4.2.2* DETACHMENT BETWEEN TEMPORARY STRUCTURES, | | | ADEQUATE TEMPORARY FIXED FIRE PROTECTION SYSTEMS, AND | | | PORTABLE EQUIPMENT SHALL BE PROVIDED AS REQUIRED BY THE | | | AUTHORITY HAVING JURISDICTION. | | | | | | | | | | | | PLEASE PROVIDE A DETAILED SITE PLAN WITH EXACT | | | LOCATIONS WITH SEPARATION DISTANCES FROM ALL OTHER | | | PROPOSED TEMPOERY BUILDINGS/TRAILERS AND NEW | | | CONSTRUCTION BUILDINGS THAT MEET THE REQUIREMENTS OF | | | THE ABOVE CODE. | | | | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-04-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-04-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-04-30 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2018-04-30 16:59:54 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THE PLAN WAS UNCLEAR AS TO THE LOCATION(S) OF THE | | | TRAILER(S) AND COMPLAINCE WITH NFPA 241 AS NOTED BELOW: | | | | | | | | | CONSTRUCTION TRAILERS | | | PER NFPA 241, 4.2 TEMPORARY OFFICES AND SHEDS; | | | | | | TABLE 4.2.1 SEPARATION DISTANCES, FIRE SPRINKLERS ARE | | | REQUIRED IN EACH TRAILER. | | | 4.2.1* SEPARATION DISTANCES BETWEEN BUILDINGS UNDER | | | CONSTRUCTION AND CONSTRUCTION-RELATED STRUCTURES, SUCH | | | AS TEMPORARY OFFICES, TRAILERS, SHEDS, AND OTHER | | | FACILITIES FOR THE STORAGE OF TOOLS AND MATERIALS | | | HAVING COMBUSTIBLE CONSTRUCTION OR CONTENTS, SHALL BE | | | IN ACCORDANCE WITH TABLE 4.2.1. | | | | | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | | | | NOTES: | | | (1) WHERE THE SEPARATION DISTANCE BETWEEN TEMPORARY | | | STRUCTURES IS LESS THAN THE MINIMUM SEPARATION | | | DISTANCE, THEN THE EXPOSING WALL LENGTH SHALL BE | | | CONSIDERED TO BE THE SUM OF THE INDIVIDUAL EXPOSING | | | WALL LENGTHS OF THE TEMPORARY STRUCTURES. | | | (2) A 75 PERCENT REDUCTION IN SEPARATION DISTANCES | | | SHALL BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | (3) THE SEPARATION DISTANCES APPLY TO SINGLE-LEVEL | | | STRUCTURES ONLY. THIS TABLE DOES NOT APPLY TO | | | MULTILEVEL, UNSPRINKLERED STRUCTURES. A LEVEL, WHERE | | | APPLYING THIS TABLE, IS 3600 MM (144 IN.). | | | | | | 4.2.2* DETACHMENT BETWEEN TEMPORARY STRUCTURES, | | | ADEQUATE TEMPORARY FIXED FIRE PROTECTION SYSTEMS, AND | | | PORTABLE EQUIPMENT SHALL BE PROVIDED AS REQUIRED BY THE | | | AUTHORITY HAVING JURISDICTION. | | | | | | | | | PLEASE PROVIDE CLEAR INDICATIONS OF ALL PROPOSED | | | CONSTRUCTION TRAILERS FOR THIS PROJECT INCLUDING | | | DIMENSIONS TO ALL OTHER TRAILERS, PROPERTY LINES, | | | FUTURE BUILDING WALLS AND ENDURE THESE DIMENSION COMPLY | | | WITH THE ABOVE CODE OR PROVIDE FIRE SPRINKLERS FOR A | | | 75% REDUCTION OF SEPARATION DISTANCE. | | | | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-06-20 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-06-20 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-06-19 |
Time |
11:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-05-25 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-05-25 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-04-06 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2018-05-25 08:49:47 | TO L MARCHANT. | | 2018-04-09 12:48:36 | B12 |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2018-06-22 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-06-22 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-06-22 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2018-06-22 09:23:52 | PLEASE PROVIDE INSTALLATION DETAILS TO DEMONSTRATE | | | COMPLIANCE WITH ELEVATION OF MINIMUM FINISH FLOOR AND | | | FLOOD RESISTANCE OF THE FOUNDATION. FF TO MEET MINIMUM | | | RELATIVE TO NAV88. THIS MAY NOT BE REQUIRED IF IT IS | | | DETERMINE TO NOT APPLY, UNDR RESEARCH. | | | | | | STEVEN KENNEDY, CBO | | | ASSISTANT BUILDING OFFICIAL | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2018-06-19 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-06-19 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-06-19 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2018-06-19 11:48:52 | BATHROOM NOT FUNCTIONAL, OCCUPANTS TO USE WATER | | | DISPENSER AND PORT-O-LETS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-05-25 |
|
|
Cont ID |
|
| Sent By |
AA |
Date |
2018-05-25 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2018-05-25 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2018-05-25 08:49:27 | PROVISO: TRAILER LOCATED INSIDE CONSTRUCTION ZONE. |
|
|
|