Plan Review Details - Permit 18040248
| Plan Review Stops For Permit 18040248 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-06-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-30 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-30 |
Time |
11:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-06-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-09 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-09 |
Time |
11:13 |
Sent To |
E |
|
| Notes |
| 2018-06-09 11:42:16 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. DOCUMENTS WITH ENGINEER'S SIGNATURE AND SEAL MUST BE | | | ORIGINAL. PAPER PLANS MAY NOT BE DIGITALY SIGNED AND | | | SEALED. | | | PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, | | | DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE | | | 61G15-23.001. | | | | | | 2. PROVIDE SITE PLAN. IDENTIFY LOCATION OF PROPOSED BBG | | | GRILL. | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED ON A BOUNDARY LINE SURVEY. | | | | | | 3. PROVIDE STRUCTURAL PLANS. INCLUDE FOUNDATION PLAN | | | AND WALL SECTION PLAN. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | 4. PROVIDE COMPLETE OWNERS MANUAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-04-13 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-04-13 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-04-13 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2018-06-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-28 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-06-28 |
Time |
08:17 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-06-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-13 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-06-13 |
Time |
14:32 |
Sent To |
I |
|
| Notes |
| 2018-06-13 14:34:11 | NO ELECTRIC SHOWN JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2018-04-13 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-04-13 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-04-13 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2018-06-29 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-06-29 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-06-29 |
Time |
15:02 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2018-06-04 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-06-04 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-06-04 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2018-06-04 15:54:38 | 06/03/2018 3RD GAS REVIEW **DENIED** | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | PLAN REVIEW IS SUBJECT TO A 4XFEE IF PLANS REVIEW IS | | | DENIED FOR THE SAME COMMENTS AFTER THE 3RD REVIEW PER | | | FL ST. STAUTE 553.80 (2B) | | | | | | I HAVE PERFORMED A SITE INSPECTION. THERE IS NO | | | PER-EXISTING GAS LINE FOR THE BBQ AS YOU HAVE TOLD ME | | | AND AS IN PLAN. THERE IS ALMOST 1 MILLION BTU'S OF GAS | | | ON THIS HOME AND YOU WILL NEED TO ADDRESS IN FULL ALL | | | OF THE COMMENT'S. IF YOU REQUIRED ASSISTANCE I WOULD BE | | | WILLING TO MEET YOU ON-SITE TO HELP SIZE AND LIST | | | EVERYTHING. | | | | | | | | | 1) PLANS ARE REQUIRED TO HAVE A WET SIGNATURE BY | | | ENGINEER. DIGITALLY SIGNED PLANS ARE ONLY PERMITTED ON | | | PLANS THAT HAVE BEEN SUBMITTED DIGITALLY. FLORIDA ADMIN | | | CODE 61G15-23.001. THE PLAN IS STILL STAMPED DIGITALLY. | | | | | | 2) ANSWERED | | | | | | 3) THE VALUE OF THIS JOB SEEMS LOW. PROVIDE A BONA FIDE | | | SIGN CONTRACT TO VERIFY THE TOTAL VALVE, WPB AMEND TO | | | THE FBC 109.3. YOU MUST WRITE THE TOTAL DIFFERENCE IN | | | VALUE THAT THE CONTRACT YOU PROVIDED SHOWS. | | | | | | 4) SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE | | | LENGTH OF ALL CUT SECTIONS OF PIPE PER 2017 FBC-FUEL | | | GAS, SECS. 402.4.1, 402.4.2. OR 2017 FBC-RES SEC. | | | G2413.4.1, G2413.4.2. | | | | | | 5) SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING (IF APPLICABLE) FOR | | | EACH PIPE SIZE. WPB AMENDMENTS TO FBC SEC.107.2.1 | | | | | | 6) LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC-FUEL GAS | | | SECS.401.8, 402.2, AND TABLES 402.4 (1) THRU 402.4 (37) | | | OR 2017 FBC-RES. SEC. G2413.3, G2413.4 AND TABLES | | | G2413.4 (1 ) THROUGH G2413.4 (21). THIS IS NOT THE ONLY | | | GAS ON THIS SYSTEM. THERE IS ALMOST 1 MILLION BTU'S | | | EXISTING ON THIS HOUSE. THE SPEC'S PROVIDE FOR THIS | | | REVIEW LIST THE BBQ AS 60K BUT THE GAS ISOMETRIC ONLY | | | LIST IT AS 40K | | | | | | 7) SUBMIT MANUFACTURER'S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR THIS GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. WHAT | | | YOU PROVIDED DOES NOT LIST ANY APPROVALS | | | | | | 8) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | | THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE | | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC-FUEL | | | GAS SECS. 401.4, 401.8, 402.3, AND TABLES 402.4 (1) | | | THRU 402.4 (37) OR 2017 FBC-RES. SEC. G2413.3, G2412.8, | | | G2413.1, G2413.2, & G2413.3. YOU SUBMITTED 2 DIFFERENT | | | SIZING CHART. WHAT PRESSURE DROP ARE YOU USING AND LIST | | | WHAT CODE BOOK THIS IS FROM. ALSO YOU WILL NEED TO | | | INCLUDE THE 2 PSI SIZING CHARTS FOR THE DIFFERENT PIPIE | | | MATERIAL BEING USED. | | | | | | 9) SHOW THE LOCATION OF ALL MP (STEP-DOWN) REGULATORS. | | | A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY | | | AHEAD OF EACH MP REGULATOR. 2017 FBC-FUEL GAS | | | SEC.409.4, FBC-RESIDENTIAL SEC. G 2420.4. | | | | | | 10) ) THE PLANS INDICATE AN EXISTING GAS METER. THE BTU | | | LOAD OF THE EXISTING GAS SYSTEM MUST BE ADDED INTO THE | | | TOTAL BTU LOAD ON THE SYSTEM TO ENSURE THE EXISTING | | | SYSTEM IS PROPERLY SIZED. IF UNDERSIZED, THE EXISTING | | | SYSTEM MUST BE REDONE TO ENSURE A SAFE OPERATING | | | SYSTEM. SUBMIT A GAS PIPING RISER DIAGRAM THAT SHOWS | | | THE TYPE OF EXISTING APPLIANCE, THE BTU LOAD OF EACH | | | APPLIANCE, THE PIPE SIZE AND TYPE OF PIPE TO EACH | | | APPLIANCE, AND THE DISTANCE OF THE LONGEST LENGTH OF | | | PIPING FROM THE POINT OF DELIVERY TO THE MOST REMOTE | | | OUTLET AND THE LOAD OF THE SECTION. NOTE: IF THE | | | EXISTING SYSTEM IS LESS THAN A 2 PSI SYSTEM AND THE | | | SYSTEM PRESSURE IS INCREASED TO 2 PSI, A LINE PRESSURE | | | REGULATOR IS REQUIRED AT ALL THE EXISTING APPLIANCES. | | | FGC SECS. 401.4, 401.8, 402.1, 402.2, 402.3 OR FBCR | | | SECS.G2412.4, G2412.8, G2413.1, G2413.2, G2413.3. | | | | | | 11) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION. 2014 FGC SEC.410.1, 2017 FBC-RES. SEC. | | | G2421.1. | | | | | | 12) SHOW THE DISTANCE FROM THE 2 PSI REGULATOR TO THE | | | APPLIANCE. COMPLY WITH 2017 FBC-FUEL GAS SEC. 402.4.1 | | | OR 2017 FBC-RES. SEC. G2413.4.1, G2413.4.2 FOR THE | | | PROPER PIPE SIZE AND BTU LOAD. | | | | | | 13) ANSWERED | | | | | | 14) ANSWERED | | | | | | . | | | | | | TIM HUNT | | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | 561-805-6695 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-05-25 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-05-25 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-05-25 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2018-05-25 14:04:18 | 04/12/2018 2ND GAS REVIEW **DENIED** | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | PLAN REVIEW IS SUBJECT TO A 4XFEE IF PLANS REVIEW IS | | | DENIED FOR THE SAME COMMENTS AFTER THE 3RD REVIEW PER | | | FL ST. STAUTE 553.80 (2B) | | | | | | | | | 1) PLANS ARE REQUIRED TO HAVE A WET SIGNATURE BY | | | ENGINEER. DIGITALLY SIGNED PLANS ARE ONLY PERMITTED ON | | | PLANS THAT HAVE BEEN SUBMITTED DIGITALLY. FLORIDA ADMIN | | | CODE 61G15-23.001 | | | | | | 2) ANSWERED | | | | | | 3) THE VALUE OF THIS JOB SEEMS LOW. PROVIDE A BONA FIDE | | | SIGN CONTRACT TO VERIFY THE TOTAL VALVE, WPB AMEND TO | | | THE FBC 109.3 | | | | | | 4) SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE | | | LENGTH OF ALL CUT SECTIONS OF PIPE PER 2017 FBC-FUEL | | | GAS, SECS. 402.4.1, 402.4.2. OR 2017 FBC-RES SEC. | | | G2413.4.1, G2413.4.2. | | | | | | 5) SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING (IF APPLICABLE) FOR | | | EACH PIPE SIZE. WPB AMENDMENTS TO FBC SEC.107.2.1 | | | | | | 6) LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC-FUEL GAS | | | SECS.401.8, 402.2, AND TABLES 402.4 (1) THRU 402.4 (37) | | | OR 2017 FBC-RES. SEC. G2413.3, G2413.4 AND TABLES | | | G2413.4 (1 ) THROUGH G2413.4 (21). | | | | | | 7) SUBMIT MANUFACTURER'S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR THIS GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1 | | | | | | 8) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | | THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE | | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC-FUEL | | | GAS SECS. 401.4, 401.8, 402.3, AND TABLES 402.4 (1) | | | THRU 402.4 (37) OR 2017 FBC-RES. SEC. G2413.3, G2412.8, | | | G2413.1, G2413.2, & G2413.3 | | | | | | 9) SHOW THE LOCATION OF ALL MP (STEP-DOWN) REGULATORS. | | | A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY | | | AHEAD OF EACH MP REGULATOR. 2017 FBC-FUEL GAS | | | SEC.409.4, FBC-RESIDENTIAL SEC. G 2420.4. | | | | | | 10) ) THE PLANS INDICATE AN EXISTING GAS METER. THE BTU | | | LOAD OF THE EXISTING GAS SYSTEM MUST BE ADDED INTO THE | | | TOTAL BTU LOAD ON THE SYSTEM TO ENSURE THE EXISTING | | | SYSTEM IS PROPERLY SIZED. IF UNDERSIZED, THE EXISTING | | | SYSTEM MUST BE REDONE TO ENSURE A SAFE OPERATING | | | SYSTEM. SUBMIT A GAS PIPING RISER DIAGRAM THAT SHOWS | | | THE TYPE OF EXISTING APPLIANCE, THE BTU LOAD OF EACH | | | APPLIANCE, THE PIPE SIZE AND TYPE OF PIPE TO EACH | | | APPLIANCE, AND THE DISTANCE OF THE LONGEST LENGTH OF | | | PIPING FROM THE POINT OF DELIVERY TO THE MOST REMOTE | | | OUTLET AND THE LOAD OF THE SECTION. NOTE: IF THE | | | EXISTING SYSTEM IS LESS THAN A 2 PSI SYSTEM AND THE | | | SYSTEM PRESSURE IS INCREASED TO 2 PSI, A LINE PRESSURE | | | REGULATOR IS REQUIRED AT ALL THE EXISTING APPLIANCES. | | | FGC SECS. 401.4, 401.8, 402.1, 402.2, 402.3 OR FBCR | | | SECS.G2412.4, G2412.8, G2413.1, G2413.2, G2413.3. | | | | | | 11) SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION. 2014 FGC SEC.410.1, 2017 FBC-RES. SEC. | | | G2421.1. | | | | | | 12) SHOW THE DISTANCE FROM THE 2 PSI REGULATOR TO THE | | | APPLIANCE. COMPLY WITH 2017 FBC-FUEL GAS SEC. 402.4.1 | | | OR 2017 FBC-RES. SEC. G2413.4.1, G2413.4.2 FOR THE | | | PROPER PIPE SIZE AND BTU LOAD. | | | | | | 13) YOU HAVE NOT INCLUDED THE HOOD VENT DOCUMENTATION | | | IN THIS PACKET. SUBMIT DRAWNINGS AND MANUFACTURE SPEC | | | FOR THE HOOD VENT SYSTEM AS REQUIRED IN FBC- FUEL AND | | | GAS 623.5 | | | | | | 14) TO THE LEFT OF THE BBQ IS WHAT LOOKS TO BE A | | | SMOKER. WILL THIS ALSO BE CONNECTED INTO THE NATURAL | | | GAS SYSTEM? WHAT FUEL IS TO BE USED? FBC 107.2.1 | | | | | | TIM HUNT | | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | 561-805-6695 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-04-12 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-04-12 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-04-12 |
Time |
17:46 |
Sent To |
|
|
| Notes |
| 2018-04-12 18:22:35 | 04/12/2018 1ST GAS REVIEW **DENIED** | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | | | | 1) PLANS ARE REQUIRED TO HAVE A WET SIGNATURE BY | | | ENGINEER. DIGITALLY SIGNED PLANS ARE ONLY PERMITTED ON | | | PLANS THAT HAVE BEEN SUBMITTED DIGITALLY. FLORIDA ADMIN | | | CODE 61G15-23.001 | | | | | | 2) YOU WILL NEED A SUB GAS PERMIT APPLICATION SUBMITTED | | | BY A LICENSE CONTRACTOR THAT GAS FALLS WITH IN THEIR | | | SCOPE OF WORK. FBC 105.1 | | | | | | 3) THE VALUE OF THIS JOB SEEMS LOW. PROVIDE A BONA FIDE | | | SIGN CONTRACT TO VERIFY THE TOTAL VALVE, WPB AMEND TO | | | THE FBC 109.3 | | | | | | 4) SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE | | | LENGTH OF ALL CUT SECTIONS OF PIPE PER 2017 FBC-FUEL | | | GAS, SECS. 402.4.1, 402.4.2. OR 2017 FBC-RES SEC. | | | G2413.4.1, G2413.4.2. | | | | | | 5) SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING (IF APPLICABLE) FOR | | | EACH PIPE SIZE. WPB AMENDMENTS TO FBC SEC.107.2.1 | | | | | | 6) LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC-FUEL GAS | | | SECS.401.8, 402.2, AND TABLES 402.4 (1) THRU 402.4 (37) | | | OR 2017 FBC-RES. SEC. G2413.3, G2413.4 AND TABLES | | | G2413.4 (1 ) THROUGH G2413.4 (21). | | | | | | 7) SUBMIT MANUFACTURER'S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR THIS GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1 | | | | | | 8) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | | THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE | | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC-FUEL | | | GAS SECS. 401.4, 401.8, 402.3, AND TABLES 402.4 (1) | | | THRU 402.4 (37) OR 2017 FBC-RES. SEC. G2413.3, G2412.8, | | | G2413.1, G2413.2, & G2413.3 | | | | | | 9) SHOW THE LOCATION OF ALL MP (STEP-DOWN) REGULATORS. | | | A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY | | | AHEAD OF EACH MP REGULATOR. 2017 FBC-FUEL GAS | | | SEC.409.4, FBC-RESIDENTIAL SEC. G 2420.4. | | | | | | 10) ) THE PLANS INDICATE AN EXISTING GAS METER. THE BTU | | | LOAD OF THE EXISTING GAS SYSTEM MUST BE ADDED INTO THE | | | TOTAL BTU LOAD ON THE SYSTEM TO ENSURE THE EXISTING | | | SYSTEM IS PROPERLY SIZED. IF UNDERSIZED, THE EXISTING | | | SYSTEM MUST BE REDONE TO ENSURE A SAFE OPERATING | | | SYSTEM. SUBMIT A GAS PIPING RISER DIAGRAM THAT SHOWS | | | THE TYPE OF EXISTING APPLIANCE, THE BTU LOAD OF EACH | | | APPLIANCE, THE PIPE SIZE AND TYPE OF PIPE TO EACH | | | APPLIANCE, AND THE DISTANCE OF THE LONGEST LENGTH OF | | | PIPING FROM THE POINT OF DELIVERY TO THE MOST REMOTE | | | OUTLET AND THE LOAD OF THE SECTION. NOTE: IF THE | | | EXISTING SYSTEM IS LESS THAN A 2 PSI SYSTEM AND THE | | | SYSTEM PRESSURE IS INCREASED TO 2 PSI, A LINE PRESSURE | | | REGULATOR IS REQUIRED AT ALL THE EXISTING APPLIANCES. | | | FGC SECS. 401.4, 401.8, 402.1, 402.2, 402.3 OR FBCR | | | SECS.G2412.4, G2412.8, G2413.1, G2413.2, G2413.3. | | | | | | 11) SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION. 2014 FGC SEC.410.1, 2017 FBC-RES. SEC. | | | G2421.1. | | | | | | 12) SHOW THE DISTANCE FROM THE 2 PSI REGULATOR TO THE | | | APPLIANCE. COMPLY WITH 2017 FBC-FUEL GAS SEC. 402.4.1 | | | OR 2017 FBC-RES. SEC. G2413.4.1, G2413.4.2 FOR THE | | | PROPER PIPE SIZE AND BTU LOAD. | | | | | | 13) YOU HAVE NOT INCLUDED THE HOOD VENT DOCUMENTATION | | | IN THIS PACKET. SUBMIT DRAWNINGS AND MANUFACTURE SPEC | | | FOR THE HOOD VENT SYSTEM AS REQUIRED IN FBC- FUEL AND | | | GAS 623.5 | | | | | | 14) TO THE LEFT OF THE BBQ IS WHAT LOOKS TO BE A | | | SMOKER. WILL THIS ALSO BE CONNECTED INTO THE NATURAL | | | GAS SYSTEM? WHAT FUEL IS TO BE USED? FBC 107.2.1 | | | | | | TIM HUNT | | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | 561-805-6695 | | | [email protected] | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-05-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-05-23 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-05-23 |
Time |
09:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-04-10 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-04-10 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-04-10 |
Time |
10:52 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-06-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-30 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-19 |
Time |
14:09 |
Sent To |
I |
|
| Notes |
| 2018-06-20 14:10:07 | RESUB ROUTED TO JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-06-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-13 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-05-31 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2018-06-01 13:01:05 | RESUB ROUTED TO THUNT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-05-25 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-05-25 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-05-14 |
Time |
13:19 |
Sent To |
I |
|
| Notes |
| 2018-05-15 13:19:21 | RESUB ROUTED TO HISTORIC INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-04-13 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-04-13 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-04-05 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2018-04-06 12:37:44 | ROUTED TO HISTORIC INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-05-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-05-23 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-05-23 |
Time |
09:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-04-10 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-04-10 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-04-10 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
|