| Plan Review Stops For Permit 18040245 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2019-03-26 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-03-26 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-03-26 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2019-03-26 15:43:36 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY E.I., BN, PX | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 4TH REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1. SEE COMMENTS FROM PREVIOUS LIST. A DETAIL SHOWING | | | HEIGHT OF THE AWNING WAS PROVIDED. HOWEVER THE AWNING | | | EXTEND MORE THAN 5 FEET OVER PUBLIC PROPERTY. PROVIDE | | | DEPTH AND HEIGHT MEASUREMENTS. FBC 3105.3.1.4 MOVABLE | | | FABRIC AWNINGS OR FABRIC COVERED FRAMES MAY EXTEND OVER | | | PUBLIC PROPERTY FOR A DISTANCE OF NOT MORE THAN 5 FEET | | | (1524 MM), PROVIDED SUCH AWNINGS OR ANY PART THEREOF | | | MAINTAIN A CLEAR HEIGHT OF 8 FEET (2438 MM) ABOVE THE | | | SIDEWALK. ALL SUCH MOVABLE AWNINGS SHALL BE SUPPORTED | | | ON METAL FRAMES ATTACHED TO THE BUILDING. | | | | | | 2. 3. PROVIDE AWNINGS FABRIC FLAME SPREAD CRITERA. FBC | | | 3105.3.4.1 FABRIC USED FOR AWNINGS OR FABRIC-COVERED | | | FRAMES SHALL MEET THE FLAME PROPAGATION PERFORMANCE | | | CRITERIA OF NFPA 701 OR HAVE A FLAME SPREAD INDEX NOT | | | GREATER THAN 25 WHEN TESTED IN ACCORDANCE WITH ASTM E84 | | | OR UL 723. | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | | | | A THOROUGH REVIEW COULD NOT BE COMPLETED AT THIS TIME, | | | AS A RESULT OF THE ADDITIONAL INFORMATION REQUESTED. | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-02 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-02 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2018-09-02 12:14:09 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC FLORIDA BUILDING CODE 2017 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION / FRC FLORIDA RESIDENTIAL CODE | | | 2017 6TH EDITION | | | | | | SEE COMMENTS FROM PREVIOUS LIST. A SITE PLAN SHOWING | | | LOCATION OF THE AWNING RELATIVE TO THE SIDEWALK AND | | | PROPERTY LINE WAS NOT PROVIDED. A DETAIL SHOWING HEIGHT | | | OF THE AWNING WAS NOT PROVIDED. NOT ENOUGH INFORMATION | | | PROVIDED TO DETERMINE CODE COMPLIANCE. | | | | | | | | | 1. RETRACTABLE AWNING. | | | | | | FBC 3105.3 DESIGN AND CONSTRUCTION. | | | | | | AWNINGS AND CANOPIES SHALL BE DESIGNED AND CONSTRUCTED | | | TO WITHSTAND WIND OR OTHER LATERAL LOADS AND LIVE LOADS | | | AS REQUIRED BY CHAPTER 16 AND IN ACCORDANCE WITH | | | SECTION 3105.4 OF THIS CODE WITH DUE ALLOWANCE FOR | | | SHAPE, OPEN CONSTRUCTION AND SIMILAR FEATURES THAT | | | RELIEVE THE PRESSURES OR LOADS. STRUCTURAL MEMBERS | | | SHALL BE PROTECTED TO PREVENT DETERIORATION. AWNINGS | | | SHALL HAVE FRAMES OF NONCOMBUSTIBLE MATERIAL, | | | FIRE-RETARDANT-TREATED WOOD, WOOD OF TYPE IV SIZE, OR | | | 1-HOUR CONSTRUCTION WITH COMBUSTIBLE OR NONCOMBUSTIBLE | | | COVERS AND SHALL BE EITHER FIXED, RETRACTABLE, FOLDING | | | OR COLLAPSIBLE. | | | | | | 2. AWNING HEIGHT | | | | | | PROVIDE DEPTH AND HEIGHT MEASUREMENTS. | | | FBC 3105.3.1.4 | | | | | | MOVABLE FABRIC AWNINGS OR FABRIC COVERED FRAMES MAY | | | EXTEND OVER PUBLIC PROPERTY FOR A DISTANCE OF NOT MORE | | | THAN 5 FEET (1524 MM), PROVIDED SUCH AWNINGS OR ANY | | | PART THEREOF MAINTAIN A CLEAR HEIGHT OF 8 FEET (2438 | | | MM) ABOVE THE SIDEWALK. ALL SUCH MOVABLE AWNINGS SHALL | | | BE SUPPORTED ON METAL FRAMES ATTACHED TO THE BUILDING. | | | | | | 3. PROVIDE AWNINGS FABRIC FLAME SPREAD CRITERA. | | | FBC 3105.3.4.1 | | | | | | FABRIC USED FOR AWNINGS OR FABRIC-COVERED FRAMES SHALL | | | MEET THE FLAME PROPAGATION PERFORMANCE CRITERIA OF NFPA | | | 701 OR HAVE A FLAME SPREAD INDEX NOT GREATER THAN 25 | | | WHEN TESTED IN ACCORDANCE WITH ASTM E84 OR UL 723. | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | | | | A THOROUGH REVIEW COULD NOT BE COMPLETED AT THIS TIME, | | | AS A RESULT OF THE ADDITIONAL INFORMATION REQUESTED. | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-27 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-27 |
Time |
18:09 |
Sent To |
|
|
| Notes |
| 2018-06-27 18:15:20 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC FLORIDA BUILDING CODE 2017 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION / FRC FLORIDA RESIDENTIAL CODE | | | 2017 6TH EDITION | | | | | | SEE COMMENTS FROM PREVIOUS LIST. A SITE PLAN SHOWING | | | LOCATION OF THE AWNING RELATIVE TO THE SIDEWALK AND | | | PROPERTY LINE WAS NOT PROVIDED. A DETAIL SHOWING HEIGHT | | | OF THE AWNING WAS NOT PROVIDED. NOT ENOUGH INFORMATION | | | PROVIDED TO DETERMINE CODE COMPLIANCE. | | | | | | | | | 1. RETRACTABLE AWNING. | | | | | | FBC 3105.3 DESIGN AND CONSTRUCTION. | | | | | | AWNINGS AND CANOPIES SHALL BE DESIGNED AND CONSTRUCTED | | | TO WITHSTAND WIND OR OTHER LATERAL LOADS AND LIVE LOADS | | | AS REQUIRED BY CHAPTER 16 AND IN ACCORDANCE WITH | | | SECTION 3105.4 OF THIS CODE WITH DUE ALLOWANCE FOR | | | SHAPE, OPEN CONSTRUCTION AND SIMILAR FEATURES THAT | | | RELIEVE THE PRESSURES OR LOADS. STRUCTURAL MEMBERS | | | SHALL BE PROTECTED TO PREVENT DETERIORATION. AWNINGS | | | SHALL HAVE FRAMES OF NONCOMBUSTIBLE MATERIAL, | | | FIRE-RETARDANT-TREATED WOOD, WOOD OF TYPE IV SIZE, OR | | | 1-HOUR CONSTRUCTION WITH COMBUSTIBLE OR NONCOMBUSTIBLE | | | COVERS AND SHALL BE EITHER FIXED, RETRACTABLE, FOLDING | | | OR COLLAPSIBLE. | | | | | | 2. AWNING HEIGHT | | | | | | PROVIDE DEPTH AND HEIGHT MEASUREMENTS. | | | FBC 3105.3.1.4 | | | | | | MOVABLE FABRIC AWNINGS OR FABRIC COVERED FRAMES MAY | | | EXTEND OVER PUBLIC PROPERTY FOR A DISTANCE OF NOT MORE | | | THAN 5 FEET (1524 MM), PROVIDED SUCH AWNINGS OR ANY | | | PART THEREOF MAINTAIN A CLEAR HEIGHT OF 8 FEET (2438 | | | MM) ABOVE THE SIDEWALK. ALL SUCH MOVABLE AWNINGS SHALL | | | BE SUPPORTED ON METAL FRAMES ATTACHED TO THE BUILDING. | | | | | | 3. PROVIDE AWNINGS FABRIC FLAME SPREAD CRITERA. | | | FBC 3105.3.4.1 | | | | | | FABRIC USED FOR AWNINGS OR FABRIC-COVERED FRAMES SHALL | | | MEET THE FLAME PROPAGATION PERFORMANCE CRITERIA OF NFPA | | | 701 OR HAVE A FLAME SPREAD INDEX NOT GREATER THAN 25 | | | WHEN TESTED IN ACCORDANCE WITH ASTM E84 OR UL 723. | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | | | | A THOROUGH REVIEW COULD NOT BE COMPLETED AT THIS TIME, | | | AS A RESULT OF THE ADDITIONAL INFORMATION REQUESTED. | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-04-12 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-04-12 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-04-12 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2018-04-12 10:46:21 | | | | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | 561-805-6718 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2017 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION / FRC FLORIDA RESIDENTIAL CODE | | | 2017 6TH EDITION | | | | | | 1. RETRACTABLE AWNING. | | | | | | FBC 3105.3 DESIGN AND CONSTRUCTION. | | | | | | AWNINGS AND CANOPIES SHALL BE DESIGNED AND CONSTRUCTED | | | TO WITHSTAND WIND OR OTHER LATERAL LOADS AND LIVE LOADS | | | AS REQUIRED BY CHAPTER 16 AND IN ACCORDANCE WITH | | | SECTION 3105.4 OF THIS CODE WITH DUE ALLOWANCE FOR | | | SHAPE, OPEN CONSTRUCTION AND SIMILAR FEATURES THAT | | | RELIEVE THE PRESSURES OR LOADS. STRUCTURAL MEMBERS | | | SHALL BE PROTECTED TO PREVENT DETERIORATION. AWNINGS | | | SHALL HAVE FRAMES OF NONCOMBUSTIBLE MATERIAL, | | | FIRE-RETARDANT-TREATED WOOD, WOOD OF TYPE IV SIZE, OR | | | 1-HOUR CONSTRUCTION WITH COMBUSTIBLE OR NONCOMBUSTIBLE | | | COVERS AND SHALL BE EITHER FIXED, RETRACTABLE, FOLDING | | | OR COLLAPSIBLE. | | | | | | 2. AWNING HEIGHT | | | | | | PROVIDE DEPTH AND HEIGHT MEASUREMENTS. | | | FBC 3105.3.1.4 | | | | | | MOVABLE FABRIC AWNINGS OR FABRIC COVERED FRAMES MAY | | | EXTEND OVER PUBLIC PROPERTY FOR A DISTANCE OF NOT MORE | | | THAN 5 FEET (1524 MM), PROVIDED SUCH AWNINGS OR ANY | | | PART THEREOF MAINTAIN A CLEAR HEIGHT OF 8 FEET (2438 | | | MM) ABOVE THE SIDEWALK. ALL SUCH MOVABLE AWNINGS SHALL | | | BE SUPPORTED ON METAL FRAMES ATTACHED TO THE BUILDING. | | | | | | 3. PROVIDE AWNINGS FABRIC FLAME SPREAD CRITERA. | | | FBC 3105.3.4.1 | | | | | | FABRIC USED FOR AWNINGS OR FABRIC-COVERED FRAMES SHALL | | | MEET THE FLAME PROPAGATION PERFORMANCE CRITERIA OF NFPA | | | 701 OR HAVE A FLAME SPREAD INDEX NOT GREATER THAN 25 | | | WHEN TESTED IN ACCORDANCE WITH ASTM E84 OR UL 723. | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | | | | A THOROUGH REVIEW COULD NOT BE COMPLETED AT THIS TIME, | | | AS A RESULT OF THE ADDITIONAL INFORMATION REQUESTED. | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-03-26 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-03-26 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-11 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2019-02-12 09:44:31 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-02 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-10 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2018-08-13 14:11:49 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-27 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-11 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2018-06-27 12:09:39 | 6/27 TO SH DESK | | | | | 2018-06-12 14:11:27 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-04-12 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-04-12 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-04-05 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2018-04-06 12:38:48 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2019-03-20 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-03-20 |
Time |
15:27 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2019-03-20 |
Time |
15:27 |
Sent To |
B |
|
| Notes |
| 2019-03-20 15:27:26 | FAILED | | | | | | PROVIDE RESPONSES IN WRITING. | | | | | | 1) REPEAT COMMENT: THE CITYPLACE MASTER SIGN PLAN | | | REQUIRES THAT AWNINGS SHALL PROVIDE A MINIMUM OF EIGHT | | | (8) FEET OF CLEARANCE BETWEEN THE FLOOR AND THE LOWEST | | | POINT OF THE AWNING. THE PERMIT DOES NOT INCLUDE THE | | | CLEARANCE OF THE LOWEST POINT OF THE AWNING. THIS NEEDS | | | TO BE SHOWN AT THE FULL EXTENSION OF 11 FEET SO THAT | | | STAFF CAN VERIFY ADEQUATE CLEARANCE IN THE EVENT THAT | | | THE AWING IS FULLY EXTENDED. | | | | | | 2) REPEAT COMMENT: THE CITYPLACE MASTER SIGN PLAN | | | REQUIRES THAT AWNINGS ON THE STREET LEVEL SHALL PROJECT | | | FOUR (4) FEET FROM THE BUILDING FACADE, UNLESS | | | OTHERWISE APPROVED BY CITYPLACE RETAIL IN WRITING. THE | | | AWNINGS ARE LISTED AS PROJECTING EITHER SIX (6) OR | | | SEVEN (7) FEET FROM THE BUILDING FA?ADE, DEPENDING ON | | | WHICH PLAN IS USED. NO WRITTEN APPROVAL FROM CITYPLACE | | | RETAIL IS PROVIDED. THIS IS REQUIRED TO BE LETTER ON | | | CITYPLACE LETTER HEAD. | | | | | | 3) NEW COMMENT: THE NEW SURVEY PROVIDED WITH THE PERMIT | | | SHOWS THE AWNINGS PROJECTING SIX (6) FEET FROM THE | | | BUILDING FACADE. THE ENGINEERING PLANS SHOW THE AWNING | | | PROJECTING UP TO SEVEN (7) FEET FROM THE BUILDING | | | FACADE. ALL SUBMITTED PLANS, SURVEYS, ETC. MUST SHOW | | | THE SAME CONDITIONS. | | | | | | 4) NEW COMMENT: HOW WILL YOU ENSURE THAT THE AWNING | | | WILL ONLY BE EXTENDED TO THE MAXIMUM RECOMMENDED | | | PROJECTION OF SEVEN (7) FEET INSTEAD OF THE POSSIBLE | | | MAXIMUM OF 11 FEET? THE SURVEY SHOWS THAT THE FULL | | | PROJECTION WILL ENCROACH OVER THE PUBLIC SIDEWALK WITH | | | NO APPROVAL TO DO SO. | | | | | | 5) REPEAT COMMENT: THE CITYPLACE MASTER SIGN PLAN | | | REQUIRES THAT ALL AWNINGS ON STREET LEVEL MUST HAVE AN | | | EIGHT (8) INCH VERTICAL VALANCE ALONG THE FRONT OF THE | | | AWNING. THE VALANCE MUST BE PROVIDED WITH CONCEALED | | | WEIGHT TO PREVENT EXCESSIVE MOVEMENT IN HIGH WINDS. NO | | | INFORMATION IS PROVIDED REGARDING THE VALANCE. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2018-08-31 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-08-31 |
Time |
09:51 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-08-31 |
Time |
09:24 |
Sent To |
B |
|
| Notes |
| 2018-08-31 09:34:57 | FAILED | | | | | | PROVIDE RESPONSES IN WRITING. | | | | | | 1) REPEAT COMMENT: PROVIDE TWO COPIES OF A RECENT | | | SURVEY SHOWING THE DIMENSIONS OF THE AWNING AND ITS | | | PROJECTION IN RELATIONSHIP TO THE PROPERTY LINE. IF THE | | | AWNING PROJECTS OVER THE RIGHT-OF-WAY, THEN PRIOR TO | | | ZONING APPROVAL OF THIS PERMIT, YOU MUST HAVE APPROVAL | | | FROM THE ENGINEERING SERVICES DIVISION PERMITTING THE | | | ENCROACHMENT OVER THE RIGHT-OF-WAY. THE IRRIGATION PLAN | | | FROM 1999 DOES NOT QUALIFY TO MEET THIS COMMENT. | | | | | | 2) REPEAT COMMENT: THE CITYPLACE MASTER SIGN PLAN | | | REQUIRES THAT AWNINGS SHALL PROVIDE A MINIMUM OF EIGHT | | | (8) FEET OF CLEARANCE BETWEEN THE FLOOR AND THE LOWEST | | | POINT OF THE AWNING. THE PERMIT DOES NOT INCLUDE THE | | | CLEARANCE OF THE LOWEST POINT OF THE AWNING. | | | | | | 3) REPEAT COMMENT: THE CITYPLACE MASTER SIGN PLAN | | | REQUIRES THAT AWNINGS ON THE STREET LEVEL SHALL PROJECT | | | FOUR (4) FEET FROM THE BUILDING FACADE, UNLESS | | | OTHERWISE APPROVED BY CITYPLACE RETAIL IN WRITING. THE | | | AWNINGS ARE LISTED AS PROJECTING 7 FEET FROM THE | | | BUILDING FACADE. NO WRITTEN APPROVAL FROM CITYPLACE | | | RETAIL IS PROVIDED. THIS IS REQUIRED TO BE LETTER ON | | | CITYPLACE LETTER HEAD. | | | | | | 4) REPEAT COMMENT: THE CITYPLACE MASTER SIGN PLAN | | | REQUIRES THAT ALL AWNINGS ON STREET LEVEL MUST HAVE AN | | | EIGHT (8) INCH VERTICAL VALANCE ALONG THE FRONT OF THE | | | AWNING. THE VALANCE MUST BE PROVIDED WITH CONCEALED | | | WEIGHT TO PREVENT EXCESSIVE MOVEMENT IN HIGH WINDS. NO | | | INFORMATION IS PROVIDED REGARDING THE VALANCE. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-06-27 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-06-27 |
Time |
10:37 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-06-27 |
Time |
10:37 |
Sent To |
B |
|
| Notes |
| 2018-06-27 11:00:42 | FAILED | | | | | | PROVIDE RESPONSES IN WRITING. | | | | | | 1) REPEAT COMMENT: PROVIDE TWO COPIES OF A RECENT | | | SURVEY SHOWING THE DIMENSIONS OF THE AWNING AND ITS | | | PROJECTION IN RELATIONSHIP TO THE PROPERTY LINE. IF THE | | | AWNING PROJECTS OVER THE RIGHT-OF-WAY, THEN PRIOR TO | | | ZONING APPROVAL OF THIS PERMIT, YOU MUST HAVE APPROVAL | | | FROM THE ENGINEERING SERVICES DIVISION PERMITTING THE | | | ENCROACHMENT OVER THE RIGHT-OF-WAY. | | | | | | 2) REPEAT COMMENT: THE CITYPLACE MASTER SIGN PLAN | | | REQUIRES THAT THE AWNING COLORS, COPY AND/OR LOGO SHALL | | | BE APPROVED BY CITYPLACE RETAIL IN WRITING. NO WRITTEN | | | APPROVAL FROM CITYPLACE RETAIL IS PROVIDED. | | | | | | 3) REPEAT COMMENT: THE CITYPLACE MASTER SIGN PLAN | | | REQUIRES THAT AWNINGS SHALL PROVIDE A MINIMUM OF EIGHT | | | (8) FEET OF CLEARANCE BETWEEN THE FLOOR AND THE LOWEST | | | POINT OF THE AWNING. THE PERMIT DOES NOT INCLUDE THE | | | CLEARANCE OF THE LOWEST POINT OF THE AWNING. | | | | | | 4) REPEAT COMMENT: THE CITYPLACE MASTER SIGN PLAN | | | REQUIRES THAT AWNINGS ON THE STREET LEVEL SHALL PROJECT | | | FOUR (4) FEET FROM THE BUILDING FACADE, UNLESS | | | OTHERWISE APPROVED BY CITYPLACE RETAIL IN WRITING. THE | | | AWNINGS ARE LISTED AS PROJECTING 7 FEET FROM THE | | | BUILDING FACADE. NO WRITTEN APPROVAL FROM CITYPLACE | | | RETAIL IS PROVIDED. | | | | | | 5) REPEAT COMMENT: THE CITYPLACE MASTER SIGN PLAN | | | REQUIRES THAT ALL AWNINGS ON STREET LEVEL MUST HAVE AN | | | EIGHT (8) INCH VERTICAL VALANCE ALONG THE FRONT OF THE | | | AWNING. THE VALANCE MUST BE PROVIDED WITH CONCEALED | | | WEIGHT TO PREVENT EXCESSIVE MOVEMENT IN HIGH WINDS. NO | | | INFORMATION IS PROVIDED REGARDING THE VALANCE. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-04-11 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-04-11 |
Time |
11:45 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2018-04-11 |
Time |
11:45 |
Sent To |
B |
|
| Notes |
| 2018-04-11 11:48:12 | FAILED | | | | | | PROVIDE RESPONSES IN WRITING. | | | | | | 1) PROVIDE TWO COPIES OF A RECENT SURVEY SHOWING THE | | | DIMENSIONS OF THE AWNING AND ITS PROJECTION IN | | | RELATIONSHIP TO THE PROPERTY LINE. IF THE AWNING | | | PROJECTS OVER THE RIGHT-OF-WAY, THEN PRIOR TO ZONING | | | APPROVAL OF THIS PERMIT, YOU MUST HAVE APPROVAL FROM | | | THE ENGINEERING SERVICES DIVISION PERMITTING THE | | | ENCROACHMENT OVER THE RIGHT-OF-WAY. | | | | | | 2) THE CITYPLACE MANAGEMENT APPROVAL STAMP IS REQUIRED | | | ON THE PLANS. | | | | | | 3) THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT THE | | | AWNING COLORS, COPY AND/OR LOGO SHALL BE APPROVED BY | | | CITYPLACE RETAIL IN WRITING. | | | | | | 4) THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT AWNINGS | | | SHALL PROVIDE A MINIMUM OF EIGHT (8) FEET OF CLEARANCE | | | BETWEEN THE FLOOR AND THE LOWEST POINT OF THE AWNING. | | | THE PERMIT DID NOT INCLUDE THE CLEARANCE OF THE LOWEST | | | POINT OF THE AWNING. | | | | | | 5) THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT AWNINGS | | | ON THE STREET LEVEL SHALL PROJECT FOUR (4) FEET FROM | | | THE BUILDING FACADE, UNLESS OTHERWISE APPROVED BY | | | CITYPLACE RETAIL IN WRITING. THE AWNINGS ARE LISTED AS | | | PROJECTING 11 FEET FROM THE BUILDING FACADE. | | | | | | 6) THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT ALL | | | AWNINGS ON STREET LEVEL MUST HAVE AN EIGHT (8) INCH | | | VERTICAL VALANCE ALONG THE FRONT OF THE AWNING. THE | | | VALANCE MUST BE PROVIDED WITH CONCEALED WEIGHT TO | | | PREVENT EXCESSIVE MOVEMENT IN HIGH WINDS. NO | | | INFORMATION IS PROVIDED REGARDING THE VALANCE. | | | | | | 8) THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT AWNINGS | | | SHALL BE A SUNBRELLA 100% SOLUTION DYED ACRYLIC OR | | | SUNBRELLA FIRESIST 100% SOLUTION DYED MODACRYLIC | | | MATERIAL (OR EQUIVALENT APPROVED BY CITYPLACE RETAIL IN | | | WRITING). NO INFORMATION PROVIDED REGARDING THE AWNING | | | MATERIAL. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|