Plan Review Details - Permit 18040237
| Plan Review Stops For Permit 18040237 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-05-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-05-01 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-05-01 |
Time |
07:43 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-04-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-04-25 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-04-24 |
Time |
19:01 |
Sent To |
I |
|
| Notes |
| 2018-04-24 19:08:41 | THE ENGINEER'S SEAL AND ORIGINAL HANDWRITTEN SIGNATURE | | | IS REQUIRED ON THE GEOTECHNICAL ENGINEERING REPORTS | | | THAT ARE SUBMITTED FOR PUBLIC RECORD. COPIES OR OTHER | | | FACSIMILIES ARE NOT ACCEPTABLE. FAC 61G15-23.001 AND | | | 61G15-23.003 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-04-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-04-18 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-04-18 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2018-04-18 16:02:36 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE CLEARING AND GRUBBING PERMIT INCLUDES PREPARING | | | THE BUILDING PAD FOR THE STRUCTURE. THEREFORE, TWO SETS | | | OF A SUBSURFACE SOILS REPORT ARE REQUIRED WITH THE | | | SOILS ENGINEER'S RECOMMENDATIONS FOR STABILIZING THE | | | SOIL IN ORDER TO SUPPORT THE PROPOSED CONSTRUCTION. | | | 2014 FBC-B 1803.5.2 | | | | | | 2) PROVIDE A LETTER THAT PROVIDES THE NAME OF THE | | | COMPANY THAT WILL PROVIDE THE SOIL MONITORING TO VERIFY | | | THAT THE GEOTECHNICAL ENGINEER'S RECOMMENDATIONS HAVE | | | BEEN COMPLETED. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2018-04-16 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2018-04-16 |
Time |
|
Rev Time |
0.50 |
| Received By |
mgonzale |
Date |
2018-04-16 |
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-05-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-05-01 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-04-25 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2018-04-26 14:51:47 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-04-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-04-25 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-04-23 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2018-04-24 12:54:12 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-04-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-04-18 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-04-05 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2018-04-18 12:36:25 | 4/18 - TO RM DESK | | | | | 2018-04-06 15:47:18 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
hmtribou |
Date |
2018-04-09 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
hmtribou |
Date |
2018-04-09 |
Time |
13:47 |
Sent To |
ENG |
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy