| Plan Review Stops For Permit 18040193 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-10-16 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-16 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-16 |
Time |
12:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-07-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-07 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-07 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2018-07-07 11:03:45 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18040193 | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. OK | | | | | | 2. OK | | | | | | 3. NOT ADDRESSED. ON SHEET A-1, THE B-B CROSS SECTION | | | IS MIS-LABELED AS BEING ON SHEET A-4. PLEASE CORRECT | | | FBC 107.2.1 | | | | | | 4. OK | | | | | | 5. OK | | | | | | 6. PARTIALLY ADDRESSED. PLEASE ADD VESTIBULE ATTIC | | | ACCESS TO SHEET S-4. | | | | | | 7. OK | | | | | | 8. OK | | | | | | 9. IS THIS FIBERGLASS DOOR BEING USED(FL20468.4)? | | | IT LOOKS LIKE IT WAS BEING SUBMITTED AS THE VESTIBULE | | | ENTRY DOORS. THOSE DOORS SHOW ON PLAN A-1 AS 1 HR FIRE | | | RATED TO MAINTAIN THE FIRE WALL SEPARATION. | | | | | | 10. OK | | | | | | 11. UPDATE N.O.A. FOR WINDOWS ON SHEET A-2(M-D NOA | | | 0630.08) TO MATCH THE NOA PROVIDED(NOA #16-0714.06) | | | | | | 12. OK | | | | | | 13. NOT PROVIDED - IN ORDER TO REDUCE PLAN REVIEW TIME, | | | PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH OF | | | THE REVIEW COMMENTS HAS BEEN ADDRESSED. | | | | | | 14. [NEW COMMENT] ON SHEET S-4 KEYNOTE #3 HAS WALL | | | U465. WHERE ON THE PLANS DOES THIS WALL GET INSTALLED? | | | ADD NOTE TO PLANS TO SHOW WHERE THIS WALL IS INSTALLED. | | | IT LOOKS LIKE IT WOULD BE INFILL TO FINISH WHERE THERE | | | ARE NO RAKE BEAMS. | | | PLEASE LOOK AT SECTION [FBC R-302.3] TWO FAMILY | | | DWELLING. THIS IS WHAT WOULD APPLY FOR SEPARATION OF | | | THESE UNITS. | | | | | | NOTE: | | | ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | PLEASE PROVIDE TWO IDENTICAL COPIES OF ALL ITEMS | | | SUBMITTED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-04-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-04-11 |
Time |
18:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-04-10 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2018-04-11 16:56:41 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THESE PLANS ARE FOR A TWO-FAMILY DWELLING, WHICH | | | FALLS UNDER THE SCOPE OF THE 2017 FLORIDA BUILDING CODE | | | RESIDENTIAL PER CITY AMENDMENTS FBC 101.2. THIS REVIEW | | | HAS BEEN PREFORMED UNDER THE RESIDENTIAL CODE. | | | | | | 2) ON SHEET CS OF THE PLANS, THE OCCUPANCY TYPE IS | | | GIVEN AS GROUP R3 UNDER CODE AND BUILDING INFORMATION | | | AND AS R-2 UNDER COMPLIANCE REQUIREMENTS. THIS IS A | | | TWO-FAMILY DWELLING SO THERE IS NO OCCUPANCY TYPE UNDER | | | THE 2017 FBC RESIDENTIAL. | | | | | | 3) ON SHEET A-1, THE B-B CROSS SECTION IS MISLABELED AS | | | BEING ON SHEET A-5. IT IS ON SHEET A-4. PLEASE CORRECT. | | | FBC 107.2.1 | | | | | | 4) THE AREA TABULATIONS SPECIFY THAT THE COMMON AREA | | | VESTIBULE IS CONDITIONED SPACE. THIS IS NOT REFLECTED | | | ON THE MECHANICAL PLANS WHICH SHOW ONLY A110 CFM | | | EXHAUST FAN. THE EXHAUST FAN NOR THE A/C FOR THE | | | VESTIBULE ARE NOT SHOWN ON THE ELECTRICAL PLANS. PLEASE | | | CLARIFY. FBC 107.2.1 | | | | | | 5) SPECIFY THE LOCATION OF THE HOUSE ELECTRICAL PANEL | | | AND DISCONNECTING MEANS ON THE PLANS. FBCR-E3405 AND | | | E3601.6 | | | | | | 6) ATTIC ACCESS IS REQUIRED TO ALL ATTIC AREAS THAT | | | HAVE A VERTICAL HEIGHT OF 30 INCHES OVER AN AREA OF NOT | | | LESS THAN 30 SQUARE FEET. THIS WOULD INCLUDE THE 54 | | | SQFT VESTIBULE. FBC-R807.1 | | | | | | 7) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT | | | ROOFING MATERIALS, WINDOW/GLASS TYPES, STRUCTURAL | | | MULLIONS AND EXTERIOR DOOR TYPES. SUBMIT TWO SETS OF | | | PRODUCT APPROVALS FOR THE CEMENT TILE ROOF THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. | | | | | | 8) NOA NO. 14-1103.06 THAT WAS SUBMITTED FOR THE CGI | | | SERIES 450 INSWING DOOR IS EXPIRED. SUBMIT TWO SETS OF | | | CURRENT PRODUCT APPROVALS THAT HAVE BEEN REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 9) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE | | | FIBERGLASS DOORS FL-20468.4 ARE NOT LISTED IN THE | | | SCHEDULE ON SHEET A-2. PLEASE CLARIFY. FBC 107.2.1 | | | | | | 10) THE SCHEDULE ON A-2 LISTS DOOR 01 AS AN ALUMINUM | | | STOREFRONT ENTRANCE DOOR WITH NOA NO. 17-1114.04. THE | | | PRODUCT APPROVALS FOR THIS DOOR WERE NOT SUBMITTED. FBC | | | 107.3.4 | | | | | | 11) THE SCHEDULE ON A-2 LISTS WINDOWS 09 AND 04 AS SH | | | 24 - 700 SERIES WITH NOA NO. 17- 0630.08. THE OTHER | | | SINGLE HUNG WINDOWS HAVE NOA NO. 16-0714.06 AS THEIR | | | PRODUCT APPROVALS. NOA NO. 16-0714.06 HAS BEEN | | | SUPERSEDED BY NOA NO. 17-0630.08. PLEASE REVISE THE | | | SCHEDULE AND SUBMIT TWO SETS OF THE CURRENT PRODUCT | | | APPROVALS ( NOA NO. 17-0630.08 ) FBC 107.3.4 | | | | | | 12) THE FLORIDA ENERGY FORM R405-2017 HAS SOME ERRORS. | | | THIS PROJECT IS LOCATED IN WEST PALM BEACH FLORIDA AND | | | NOT DELRAY BEACH. THE CORRECT JURISDICTION NUMBER IS | | | 604700. ITEM #3 LISTS THE NUMBER OF UNITS AS ONE AND | | | THERE ARE TWO UNITS. THE ROOF MATERIALS ARE CONCRETE | | | TILES NOT COMPOSITION SHINGLES. THE VENT RATIO SHOULD | | | BE 150, UNLESS THE PLANS ARE REVISED TO SHOW THAT 40 | | | PERCENT OF THE REQUIRED ROOF VENTILATION IS LOCATED IN | | | THE UPPER PORTION OF THE ATTIC SPACE PER FBC-R806.2. | | | | | | 13) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-10-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-07 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-07 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-06-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-06-26 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-06-26 |
Time |
17:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-04-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-04-16 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-04-16 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2018-04-16 11:11:48 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ADDRESS IS NOT SHOWN ON PLANS. PROVIDE ADDRESS OF | | | PROJECT ON EACH SHEET. WPB FBC 107.2.1 | | | 2. PLAN SHOWS SOME ITEMS THAT ARE FED FROM A HOUSE | | | PANEL, BUT THERE IS NO HOUSE PANEL LISTED IN THE LOAD | | | CALCULATION TO SHOWN ON THE PLANS. CLARIFY AND/OR | | | CORRECT. WPB FBC 107.2.1 | | | 3. RISER DIAGRAM SHOWS A SINGLE GROUND ROD AS A | | | SUPPLEMENTAL GROUNDING ELECTRODE. THIS SUPPLEMENTAL | | | GROUNDING ELECTRODE NEEDS TO BE AUGMENTED BY AN | | | ADDITIONAL ELECTRODE AT LEAST 6 FEET AWAY OR PROVIDE | | | EVIDENCE OF RESISTANCE TO GROUND OF 25 OHMS OR LESS. | | | NEC 250.53(A)(2); FBC RE E3608.4 | | | 4. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | | 5. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS FOR SERVICE. THE CURRENT PLAN SHOWS ONE PANEL | | | SCHEDULE ONLY AND THE ASSOCIATED LOAD CALCULATION FOR | | | THAT UNIT. PROVIDE CORRECTION. A COMPLETE LOAD | | | CALCULATION IS REQUIRED FOR THE SERVICE SHOWING ALL | | | LOADS INCLUDING THE HOUSE PANEL. NEC 220; FBC RE | | | E3602.2 | | | 6. FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED | | | GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL | | | SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED ON | | | THE EXTERIOR SIDE OF OUTDOOR ENTRANCES/EXITS WITH GRADE | | | LEVEL ACCESS. THIS IS NOT SHOWN AT THE ENTRANCE FOR | | | EACH UNIT. PROVIDE CORRECTION. NEC 210.70(A)(2)(B), FBC | | | RE E3903.3 | | | 7. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC EC R404.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-03-01 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-01 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-02-28 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2019-03-01 14:24:38 | IMPACT FEES ROUTED TO DBATTLES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-10-16 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-16 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-04 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2018-10-05 14:38:44 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-07-10 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-07-10 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-06-21 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-04-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-30 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-05 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2019-03-01 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-01 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-01 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2019-03-01 16:49:14 | STAMP ON PLANS - OK | | | RECEIPT PROVIDED - OK | | | MU-2019-004740 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2018-10-16 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-16 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-16 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2018-10-16 13:04:17 | ALL TRADES HAVE PASSED, SO A SET OF PLANS CAN BE | | | CHECKED OUT TO RECEIVE PBC STAMP ON PLANS TO SHOW | | | IMPACT FEES PAID FOR THE SQ. FOOTAGE OF STRUCTURE. | | | | | | [FBC AMENDED 109]PLANS REQUIRE REVIEW BY THE PBC IMPACT | | | FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, YOU MAY | | | CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | | REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-04-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-04-10 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-04-10 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2018-04-10 08:39:44 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-07-09 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-07-09 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-07-09 |
Time |
15:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-04-18 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-04-18 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-04-18 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2018-10-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-10-12 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-10-12 |
Time |
06:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2018-06-30 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-06-30 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-06-30 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2018-06-30 13:14:13 | 06/30/2018 3ND PLUMBING REVIEW**DENIED** | | | | | | NOTE: A 4X PLAN REVIEW FEE WILL BE ADDED IF PLANS ARE | | | REJECTED AGAIN. FL ST. STAUTE 553.80 (2B) | | | | | | NOT ALL COMMENTS HAVE BE ADDRESS | | | | | | 1) OK | | | | | | 2) AS AN R-3 OCCUPANCY AN AUTOMATIC CLOTHS WASHER IS | | | REQUIRED IN EACH UNIT. FBC-P 403.1 BOTH FLOOR PLAN NOR | | | PLUMBING ISOMETRIC SHOW SUCH. | | | | | | 3) OK | | | | | | 4) YOU HAVE CHANGES THE WATER HEATER FROM 100 GALLONS | | | TO A 30 GALLON IN EACH UNIT BUT THE E.F RATING IS SHOWN | | | AS .93. AGAIN AS OF APRIL 16,2016 THE MIN E.F ALLOWED | | | IS .95. PLEASE REFER TO THE CODE OF FEDERAL REGULATION | | | (CFR) 75 FR 200112**DOE 10 CRF PART 430. | | | | | | 5) PLAN IS SHOWING CLEAR FLOOR SPACING REFERING TO FAIR | | | HOUSING, IS IT YOUR INTENT TO FULLY COMPLY WITH FHA? | | | FBC 107.2.1 | | | | | | 6) SHOW WATER HEATER PIPING DETAIL IN REGARDS TO THE | | | DISCHARGE PIPING FROM THE RELIEF LINE INTO THE PAN AND | | | THE PAN DRAIN DISCHARGING OUTSIDE OF THE DWELLING. | | | FBC-P 2801.6, 2801.6.1 | | | | | | IT IS HELPFUL TO PROVIDE A NARRATIVE TO THE COMMENTS. | | | | | | TIM HUNT | | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | 561-805-6695 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-04-17 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-04-17 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-04-17 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2018-04-17 15:51:01 | 04/17/2018 2ND PLUMBING REVIEW**DENIED**1ST REVIEW | | | RESCINDED** | | | | | | 1) COVER SHEET INFORMATION BLOCK LIST OCCUPANCY AS R-3 | | | BUT UNDER COMPLIANCE REQUIREMENTS OCCUPANCY IS LISTED | | | AS R-2. PER FBC-P SECTION 403.1 BEING THIS BUILDING IS | | | LESS THEN 3 UNITS IT WOULD BE CLASSIFIED AS R-3 | | | | | | 2) AS AN R-3 OCCUPANCY AN AUTOMATIC CLOTHS IS REQUIRED | | | IN EACH UNIT. FBC-P 403.1 | | | | | | 3) THE ADDRESS DOES NOT APPEAR ON THE PLAN. FBC 107.2.1 | | | | | | 4) THE FLORIDA ENERGY FORM R405-2017 LIST THE WATER | | | HEATER'S AS 100 GALLON .91 E.F. RESIDENTIAL WATER | | | HEATER'S MANUFACTURED AFTER APRIL 16, 2015 ARE | | | PERMITTED TO BE MAX 55 GALLON WITH A MIN E.F OF .95 | | | UNLESS THE HEATER IS OF HEAT PUMP TECHNOLOGY THEN THE | | | MIN E.F (LARGER THEN 55 GALLON) WOULD THEN BE 1.98E.F. | | | FBC- EFFICIENCY CONSERVATION R403.5.6.2 AND DEFINED IN | | | THE | | | CODE OF FEDERAL REGULATION ( CFR) 75 FR 2012. | | | | | | 5) THE BATHROOMS ARE SHOWING AS HAVING ACCESSIBILITY | | | COMPLAINT CLEAR FLOOR SPACES AND ROLL IN SHOWERS. IS IT | | | YOUR INTENT TO FULLY COMPLY WITH THE FLORIDA | | | ACCESSIBILITY CODE IN FULL? FBC 107.2.1 | | | | | | 6) SHOW WATER HEATER DETAIL IN REGARDS TO THE PIPING | | | FOR THE REQUIRED PAN DRAIN AND DISCHARGING OF THE | | | RELIEF LINE INTO THE ROOM. FBC-P 2801.6, 2801.6.1, | | | 2804.6.1 | | | | | | 7) BOTH UNIT AS LISTED AS UNIT # A. PLEASE CORRECT | | | SHOWING THE 2ND UNIT AS DIFFERENT | | | | | | TIM HUNT | | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | 561-805-6695 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-04-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-17 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-17 |
Time |
09:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2018-10-16 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-16 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-16 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2018-10-16 12:59:19 | PROVISO: | | | CONTRACTOR TO SUPPLY TILE ROOF ATTACHMENT TYPE PRODUCT | | | APPROVAL. | | | UNDERLAYMENT AND TILE PRODUCT APPROVALS - OK |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-07-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-07 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-07 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2018-07-07 14:18:21 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18061027(ROOFING) FOR MAIN PERMIT # | | | 18040193 | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. [FBC 107.3.4]WHAT IS THE ATTACHMENT TYPE FOR CEMENT | | | ROOF TILES? SUPPLY NOA FOR ADHESIVE TYPE (SEE | | | FL7804-R10 P.5 OF 6) IF APPLICABLE. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-10-12 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2018-10-12 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-10-12 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2018-10-12 09:29:29 | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY EXISTING | | | TREES ON THE SITE, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED TO, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT ? PLANNING DIVISION. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-07-10 |
|
|
Cont ID |
|
| Sent By |
JR |
Date |
2018-07-10 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-07-10 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2018-07-10 09:30:37 | PROVISO | | | | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY EXISTING | | | TREES ON THE SITE, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED TO, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT ? PLANNING DIVISION. | | | | | | 2. SEPARATE PERMIT REQUIRED FOR LANDSCAPING AND | | | IRRIGATION. | | | | | | 3. ALL FENCING SURROUNDING THE TRASH ENCLOSURES SHALL | | | BE SOLID/OPAQUE (CHAIN LINK WITH SLATS DOES NOT MEET | | | THIS REQUIREMENT). | | | | | | 4. ALL A/C CONDENSING UNITS SHALL BE A MINIMUM OF 11 | | | FEET FROM THE PROPERTY LINE. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL | | | PLANNER, AT [email protected] OR (561) 822-1448. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-04-26 |
|
|
Cont ID |
|
| Sent By |
JR |
Date |
2018-04-26 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-04-26 |
Time |
11:36 |
Sent To |
PC |
|
| Notes |
| 2018-04-26 13:51:13 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 04.26.2018 | | | PERMIT NO.: 18040193 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT AN | | | APPLICATION FOR AN INFORMAL SITE PLAN REVIEW SHALL BE | | | APPROVED BY THE DEVELOPMENT SERVICES DEPARTMENT ? | | | PLANNING DIVISION. SUCH APPLICATION HAS ALREADY BEEN | | | SUBMITTED AND IS UNDER REVIEW. UPON APPROVAL OF THE | | | SITE PLAN REVIEW, ALL DRAWINGS SUBMITTED AS PART OF THE | | | BUILDING PERMIT SHALL MATCH THOSE WHICH WERE APPROVED. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|