Plan Review Details - Permit 18040193
Plan Review Stops For Permit 18040193
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-10-16 Cont ID  
Sent By dbattles Date 2018-10-16 Time 12:57 Rev Time 0.00
Received By dbattles Date 2018-10-16 Time 12:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-07-07 Cont ID  
Sent By shill Date 2018-07-07 Time 11:03 Rev Time 0.00
Received By shill Date 2018-07-07 Time 11:03 Sent To  
Notes
2018-07-07 11:03:45****CORRECTIONS****
 W.P.B. PERMIT: 18040193
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. OK
  
 2. OK
  
 3. NOT ADDRESSED. ON SHEET A-1, THE B-B CROSS SECTION
 IS MIS-LABELED AS BEING ON SHEET A-4. PLEASE CORRECT
 FBC 107.2.1
  
 4. OK
  
 5. OK
  
 6. PARTIALLY ADDRESSED. PLEASE ADD VESTIBULE ATTIC
 ACCESS TO SHEET S-4.
  
 7. OK
  
 8. OK
  
 9. IS THIS FIBERGLASS DOOR BEING USED(FL20468.4)?
 IT LOOKS LIKE IT WAS BEING SUBMITTED AS THE VESTIBULE
 ENTRY DOORS. THOSE DOORS SHOW ON PLAN A-1 AS 1 HR FIRE
 RATED TO MAINTAIN THE FIRE WALL SEPARATION.
  
 10. OK
  
 11. UPDATE N.O.A. FOR WINDOWS ON SHEET A-2(M-D NOA
 0630.08) TO MATCH THE NOA PROVIDED(NOA #16-0714.06)
  
 12. OK
  
 13. NOT PROVIDED - IN ORDER TO REDUCE PLAN REVIEW TIME,
 PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH OF
 THE REVIEW COMMENTS HAS BEEN ADDRESSED.
  
 14. [NEW COMMENT] ON SHEET S-4 KEYNOTE #3 HAS WALL
 U465. WHERE ON THE PLANS DOES THIS WALL GET INSTALLED?
 ADD NOTE TO PLANS TO SHOW WHERE THIS WALL IS INSTALLED.
 IT LOOKS LIKE IT WOULD BE INFILL TO FINISH WHERE THERE
 ARE NO RAKE BEAMS.
 PLEASE LOOK AT SECTION [FBC R-302.3] TWO FAMILY
 DWELLING. THIS IS WHAT WOULD APPLY FOR SEPARATION OF
 THESE UNITS.
  
 NOTE:
 ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 PLEASE PROVIDE TWO IDENTICAL COPIES OF ALL ITEMS
 SUBMITTED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-04-11 Cont ID  
Sent By rmcdouga Date 2018-04-11 Time 18:14 Rev Time 0.00
Received By rmcdouga Date 2018-04-10 Time 08:39 Sent To  
Notes
2018-04-11 16:56:41PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THESE PLANS ARE FOR A TWO-FAMILY DWELLING, WHICH
 FALLS UNDER THE SCOPE OF THE 2017 FLORIDA BUILDING CODE
 RESIDENTIAL PER CITY AMENDMENTS FBC 101.2. THIS REVIEW
 HAS BEEN PREFORMED UNDER THE RESIDENTIAL CODE.
  
 2) ON SHEET CS OF THE PLANS, THE OCCUPANCY TYPE IS
 GIVEN AS GROUP R3 UNDER CODE AND BUILDING INFORMATION
 AND AS R-2 UNDER COMPLIANCE REQUIREMENTS. THIS IS A
 TWO-FAMILY DWELLING SO THERE IS NO OCCUPANCY TYPE UNDER
 THE 2017 FBC RESIDENTIAL.
  
 3) ON SHEET A-1, THE B-B CROSS SECTION IS MISLABELED AS
 BEING ON SHEET A-5. IT IS ON SHEET A-4. PLEASE CORRECT.
 FBC 107.2.1
  
 4) THE AREA TABULATIONS SPECIFY THAT THE COMMON AREA
 VESTIBULE IS CONDITIONED SPACE. THIS IS NOT REFLECTED
 ON THE MECHANICAL PLANS WHICH SHOW ONLY A110 CFM
 EXHAUST FAN. THE EXHAUST FAN NOR THE A/C FOR THE
 VESTIBULE ARE NOT SHOWN ON THE ELECTRICAL PLANS. PLEASE
 CLARIFY. FBC 107.2.1
  
 5) SPECIFY THE LOCATION OF THE HOUSE ELECTRICAL PANEL
 AND DISCONNECTING MEANS ON THE PLANS. FBCR-E3405 AND
 E3601.6
  
 6) ATTIC ACCESS IS REQUIRED TO ALL ATTIC AREAS THAT
 HAVE A VERTICAL HEIGHT OF 30 INCHES OVER AN AREA OF NOT
 LESS THAN 30 SQUARE FEET. THIS WOULD INCLUDE THE 54
 SQFT VESTIBULE. FBC-R807.1
  
 7) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT
 ROOFING MATERIALS, WINDOW/GLASS TYPES, STRUCTURAL
 MULLIONS AND EXTERIOR DOOR TYPES. SUBMIT TWO SETS OF
 PRODUCT APPROVALS FOR THE CEMENT TILE ROOF THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD.
  
 8) NOA NO. 14-1103.06 THAT WAS SUBMITTED FOR THE CGI
 SERIES 450 INSWING DOOR IS EXPIRED. SUBMIT TWO SETS OF
 CURRENT PRODUCT APPROVALS THAT HAVE BEEN REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 9) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE
 FIBERGLASS DOORS FL-20468.4 ARE NOT LISTED IN THE
 SCHEDULE ON SHEET A-2. PLEASE CLARIFY. FBC 107.2.1
  
 10) THE SCHEDULE ON A-2 LISTS DOOR 01 AS AN ALUMINUM
 STOREFRONT ENTRANCE DOOR WITH NOA NO. 17-1114.04. THE
 PRODUCT APPROVALS FOR THIS DOOR WERE NOT SUBMITTED. FBC
 107.3.4
  
 11) THE SCHEDULE ON A-2 LISTS WINDOWS 09 AND 04 AS SH
 24 - 700 SERIES WITH NOA NO. 17- 0630.08. THE OTHER
 SINGLE HUNG WINDOWS HAVE NOA NO. 16-0714.06 AS THEIR
 PRODUCT APPROVALS. NOA NO. 16-0714.06 HAS BEEN
 SUPERSEDED BY NOA NO. 17-0630.08. PLEASE REVISE THE
 SCHEDULE AND SUBMIT TWO SETS OF THE CURRENT PRODUCT
 APPROVALS ( NOA NO. 17-0630.08 ) FBC 107.3.4
  
 12) THE FLORIDA ENERGY FORM R405-2017 HAS SOME ERRORS.
 THIS PROJECT IS LOCATED IN WEST PALM BEACH FLORIDA AND
 NOT DELRAY BEACH. THE CORRECT JURISDICTION NUMBER IS
 604700. ITEM #3 LISTS THE NUMBER OF UNITS AS ONE AND
 THERE ARE TWO UNITS. THE ROOF MATERIALS ARE CONCRETE
 TILES NOT COMPOSITION SHINGLES. THE VENT RATIO SHOULD
 BE 150, UNLESS THE PLANS ARE REVISED TO SHOW THAT 40
 PERCENT OF THE REQUIRED ROOF VENTILATION IS LOCATED IN
 THE UPPER PORTION OF THE ATTIC SPACE PER FBC-R806.2.
  
 13) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT
 A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2018-10-07 Cont ID  
Sent By jpearson Date 2018-10-07 Time 10:04 Rev Time 0.00
Received By jpearson Date 2018-10-07 Time 10:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-06-26 Cont ID  
Sent By jpearson Date 2018-06-26 Time 17:33 Rev Time 0.00
Received By jpearson Date 2018-06-26 Time 17:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-04-16 Cont ID  
Sent By jpearson Date 2018-04-16 Time 11:11 Rev Time 0.00
Received By jpearson Date 2018-04-16 Time 10:49 Sent To  
Notes
2018-04-16 11:11:48CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ADDRESS IS NOT SHOWN ON PLANS. PROVIDE ADDRESS OF
 PROJECT ON EACH SHEET. WPB FBC 107.2.1
 2. PLAN SHOWS SOME ITEMS THAT ARE FED FROM A HOUSE
 PANEL, BUT THERE IS NO HOUSE PANEL LISTED IN THE LOAD
 CALCULATION TO SHOWN ON THE PLANS. CLARIFY AND/OR
 CORRECT. WPB FBC 107.2.1
 3. RISER DIAGRAM SHOWS A SINGLE GROUND ROD AS A
 SUPPLEMENTAL GROUNDING ELECTRODE. THIS SUPPLEMENTAL
 GROUNDING ELECTRODE NEEDS TO BE AUGMENTED BY AN
 ADDITIONAL ELECTRODE AT LEAST 6 FEET AWAY OR PROVIDE
 EVIDENCE OF RESISTANCE TO GROUND OF 25 OHMS OR LESS.
 NEC 250.53(A)(2); FBC RE E3608.4
 4. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT
 SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3
 5. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL
 LOADS FOR SERVICE. THE CURRENT PLAN SHOWS ONE PANEL
 SCHEDULE ONLY AND THE ASSOCIATED LOAD CALCULATION FOR
 THAT UNIT. PROVIDE CORRECTION. A COMPLETE LOAD
 CALCULATION IS REQUIRED FOR THE SERVICE SHOWING ALL
 LOADS INCLUDING THE HOUSE PANEL. NEC 220; FBC RE
 E3602.2
 6. FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED
 GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL
 SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED ON
 THE EXTERIOR SIDE OF OUTDOOR ENTRANCES/EXITS WITH GRADE
 LEVEL ACCESS. THIS IS NOT SHOWN AT THE ENTRANCE FOR
 EACH UNIT. PROVIDE CORRECTION. NEC 210.70(A)(2)(B), FBC
 RE E3903.3
 7. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE.
 FBC EC R404.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2019-03-01 Cont ID  
Sent By dbattles Date 2019-03-01 Time 16:48 Rev Time 0.00
Received By dbattles Date 2019-02-28 Time 14:24 Sent To  
Notes
2019-03-01 14:24:38IMPACT FEES ROUTED TO DBATTLES

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-10-16 Cont ID  
Sent By dbattles Date 2018-10-16 Time 12:59 Rev Time 0.00
Received By dbattles Date 2018-10-04 Time 14:38 Sent To  
Notes
2018-10-05 14:38:44RESUB ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-07-10 Cont ID  
Sent By cpuell Date 2018-07-10 Time 11:23 Rev Time 0.00
Received By cpuell Date 2018-06-21 Time 15:31 Sent To  
Notes
2018-06-22 15:31:11R15

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-04-30 Cont ID  
Sent By shill Date 2018-04-30 Time 10:59 Rev Time 0.00
Received By shill Date 2018-04-05 Time 13:26 Sent To  
Notes
2018-04-06 13:26:25R15

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2019-03-01 Cont ID  
Sent By dbattles Date 2019-03-01 Time 16:48 Rev Time 0.00
Received By dbattles Date 2019-03-01 Time 16:48 Sent To  
Notes
2019-03-01 16:49:14STAMP ON PLANS - OK
 RECEIPT PROVIDED - OK
 MU-2019-004740

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2018-10-16 Cont ID  
Sent By dbattles Date 2018-10-16 Time 13:00 Rev Time 0.00
Received By dbattles Date 2018-10-16 Time 13:00 Sent To  
Notes
2018-10-16 13:04:17ALL TRADES HAVE PASSED, SO A SET OF PLANS CAN BE
 CHECKED OUT TO RECEIVE PBC STAMP ON PLANS TO SHOW
 IMPACT FEES PAID FOR THE SQ. FOOTAGE OF STRUCTURE.
  
 [FBC AMENDED 109]PLANS REQUIRE REVIEW BY THE PBC IMPACT
 FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, YOU MAY
 CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR
 REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF THE
 RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE
 OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO
 V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN
 AIRE.PDF

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-04-10 Cont ID  
Sent By rmcdouga Date 2018-04-10 Time 08:39 Rev Time 0.00
Received By rmcdouga Date 2018-04-10 Time 08:39 Sent To  
Notes
2018-04-10 08:39:44BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-07-09 Cont ID  
Sent By cmontell Date 2018-07-09 Time 15:04 Rev Time 0.00
Received By cmontell Date 2018-07-09 Time 15:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-04-18 Cont ID  
Sent By cmontell Date 2018-04-18 Time 12:45 Rev Time 0.00
Received By cmontell Date 2018-04-18 Time 12:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2018-10-12 Cont ID  
Sent By tklarge Date 2018-10-12 Time 07:01 Rev Time 0.00
Received By tklarge Date 2018-10-12 Time 06:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2018-06-30 Cont ID  
Sent By thunt Date 2018-06-30 Time 13:01 Rev Time 0.00
Received By thunt Date 2018-06-30 Time 12:49 Sent To  
Notes
2018-06-30 13:14:1306/30/2018 3ND PLUMBING REVIEW**DENIED**
  
 NOTE: A 4X PLAN REVIEW FEE WILL BE ADDED IF PLANS ARE
 REJECTED AGAIN. FL ST. STAUTE 553.80 (2B)
  
 NOT ALL COMMENTS HAVE BE ADDRESS
  
 1) OK
  
 2) AS AN R-3 OCCUPANCY AN AUTOMATIC CLOTHS WASHER IS
 REQUIRED IN EACH UNIT. FBC-P 403.1 BOTH FLOOR PLAN NOR
 PLUMBING ISOMETRIC SHOW SUCH.
  
 3) OK
  
 4) YOU HAVE CHANGES THE WATER HEATER FROM 100 GALLONS
 TO A 30 GALLON IN EACH UNIT BUT THE E.F RATING IS SHOWN
 AS .93. AGAIN AS OF APRIL 16,2016 THE MIN E.F ALLOWED
 IS .95. PLEASE REFER TO THE CODE OF FEDERAL REGULATION
 (CFR) 75 FR 200112**DOE 10 CRF PART 430.
  
 5) PLAN IS SHOWING CLEAR FLOOR SPACING REFERING TO FAIR
 HOUSING, IS IT YOUR INTENT TO FULLY COMPLY WITH FHA?
 FBC 107.2.1
  
 6) SHOW WATER HEATER PIPING DETAIL IN REGARDS TO THE
 DISCHARGE PIPING FROM THE RELIEF LINE INTO THE PAN AND
 THE PAN DRAIN DISCHARGING OUTSIDE OF THE DWELLING.
 FBC-P 2801.6, 2801.6.1
  
 IT IS HELPFUL TO PROVIDE A NARRATIVE TO THE COMMENTS.
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-04-17 Cont ID  
Sent By thunt Date 2018-04-17 Time 15:48 Rev Time 0.00
Received By thunt Date 2018-04-17 Time 15:48 Sent To  
Notes
2018-04-17 15:51:0104/17/2018 2ND PLUMBING REVIEW**DENIED**1ST REVIEW
 RESCINDED**
  
 1) COVER SHEET INFORMATION BLOCK LIST OCCUPANCY AS R-3
 BUT UNDER COMPLIANCE REQUIREMENTS OCCUPANCY IS LISTED
 AS R-2. PER FBC-P SECTION 403.1 BEING THIS BUILDING IS
 LESS THEN 3 UNITS IT WOULD BE CLASSIFIED AS R-3
  
 2) AS AN R-3 OCCUPANCY AN AUTOMATIC CLOTHS IS REQUIRED
 IN EACH UNIT. FBC-P 403.1
  
 3) THE ADDRESS DOES NOT APPEAR ON THE PLAN. FBC 107.2.1
  
 4) THE FLORIDA ENERGY FORM R405-2017 LIST THE WATER
 HEATER'S AS 100 GALLON .91 E.F. RESIDENTIAL WATER
 HEATER'S MANUFACTURED AFTER APRIL 16, 2015 ARE
 PERMITTED TO BE MAX 55 GALLON WITH A MIN E.F OF .95
 UNLESS THE HEATER IS OF HEAT PUMP TECHNOLOGY THEN THE
 MIN E.F (LARGER THEN 55 GALLON) WOULD THEN BE 1.98E.F.
 FBC- EFFICIENCY CONSERVATION R403.5.6.2 AND DEFINED IN
 THE
 CODE OF FEDERAL REGULATION ( CFR) 75 FR 2012.
  
 5) THE BATHROOMS ARE SHOWING AS HAVING ACCESSIBILITY
 COMPLAINT CLEAR FLOOR SPACES AND ROLL IN SHOWERS. IS IT
 YOUR INTENT TO FULLY COMPLY WITH THE FLORIDA
 ACCESSIBILITY CODE IN FULL? FBC 107.2.1
  
 6) SHOW WATER HEATER DETAIL IN REGARDS TO THE PIPING
 FOR THE REQUIRED PAN DRAIN AND DISCHARGING OF THE
 RELIEF LINE INTO THE ROOM. FBC-P 2801.6, 2801.6.1,
 2804.6.1
  
 7) BOTH UNIT AS LISTED AS UNIT # A. PLEASE CORRECT
 SHOWING THE 2ND UNIT AS DIFFERENT
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-04-17 Cont ID  
Sent By gjohnson Date 2018-04-17 Time 09:23 Rev Time 0.00
Received By gjohnson Date 2018-04-17 Time 09:05 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2018-10-16 Cont ID  
Sent By dbattles Date 2018-10-16 Time 12:57 Rev Time 0.00
Received By dbattles Date 2018-10-16 Time 12:57 Sent To  
Notes
2018-10-16 12:59:19PROVISO:
 CONTRACTOR TO SUPPLY TILE ROOF ATTACHMENT TYPE PRODUCT
 APPROVAL.
 UNDERLAYMENT AND TILE PRODUCT APPROVALS - OK

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2018-07-07 Cont ID  
Sent By shill Date 2018-07-07 Time 14:17 Rev Time 0.00
Received By shill Date 2018-07-07 Time 14:17 Sent To  
Notes
2018-07-07 14:18:21****CORRECTIONS****
 W.P.B. PERMIT: 18061027(ROOFING) FOR MAIN PERMIT #
 18040193
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. [FBC 107.3.4]WHAT IS THE ATTACHMENT TYPE FOR CEMENT
 ROOF TILES? SUPPLY NOA FOR ADHESIVE TYPE (SEE
 FL7804-R10 P.5 OF 6) IF APPLICABLE.
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2018-10-12 Cont ID  
Sent By jroach Date 2018-10-12 Time 09:29 Rev Time 0.00
Received By jroach Date 2018-10-12 Time 09:07 Sent To  
Notes
2018-10-12 09:29:29REVIEW STATUS: PASSED WITH PROVISOS
 ___________________________________________
  
 THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING
 PROVISOS:
  
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY EXISTING
 TREES ON THE SITE, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED TO, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT ? PLANNING DIVISION.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 2 Status P Date 2018-07-10 Cont ID  
Sent By JR Date 2018-07-10 Time 09:29 Rev Time 0.00
Received By jroach Date 2018-07-10 Time 09:29 Sent To  
Notes
2018-07-10 09:30:37PROVISO
  
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY EXISTING
 TREES ON THE SITE, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED TO, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT ? PLANNING DIVISION.
  
 2. SEPARATE PERMIT REQUIRED FOR LANDSCAPING AND
 IRRIGATION.
  
 3. ALL FENCING SURROUNDING THE TRASH ENCLOSURES SHALL
 BE SOLID/OPAQUE (CHAIN LINK WITH SLATS DOES NOT MEET
 THIS REQUIREMENT).
  
 4. ALL A/C CONDENSING UNITS SHALL BE A MINIMUM OF 11
 FEET FROM THE PROPERTY LINE.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL
 PLANNER, AT [email protected] OR (561) 822-1448.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2018-04-26 Cont ID  
Sent By JR Date 2018-04-26 Time 13:51 Rev Time 0.00
Received By jroach Date 2018-04-26 Time 11:36 Sent To PC
Notes
2018-04-26 13:51:13ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 04.26.2018
 PERMIT NO.: 18040193
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT AN
 APPLICATION FOR AN INFORMAL SITE PLAN REVIEW SHALL BE
 APPROVED BY THE DEVELOPMENT SERVICES DEPARTMENT ?
 PLANNING DIVISION. SUCH APPLICATION HAS ALREADY BEEN
 SUBMITTED AND IS UNDER REVIEW. UPON APPROVAL OF THE
 SITE PLAN REVIEW, ALL DRAWINGS SUBMITTED AS PART OF THE
 BUILDING PERMIT SHALL MATCH THOSE WHICH WERE APPROVED.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved