| Plan Review Stops For Permit 18040024 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-06-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-05 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-05 |
Time |
14:56 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-04-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-04-10 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-04-09 |
Time |
17:30 |
Sent To |
|
|
| Notes |
| 2018-04-10 10:48:00 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE DETAIL OF MECHANICAL DEVICE USED TO OPERATE | | | LOUVERS, | | | 2. PROVIDE DETAIL OF MECHANICAL/ELECTRICAL DEVICE USED | | | TO OPEN LOUVERS AT 45MPH. | | | 3. IF DEVICE IS ELECTRICALLY ACTUATED, PROVIDE | | | ELECTRICAL PLAN. | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-06-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-20 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-06-20 |
Time |
13:03 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-06-07 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-07 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-06-07 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2018-06-07 07:57:24 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 400.8 USES NOT PERMITTED | | | | | | UNLESS SPECIFICALLY PERMITTED IN 400.7, FLEXIBLE CORDS | | | AND CABLES | | | SHALL NOT BE USED FOR THE FOLLOWING: | | | | | | (1) AS A SUBSTITUTE FOR THE FIXED WIRING OF A | | | STRUCTURE. | | | | | | SUBMIT CUT SHEETS ON THE ELECTRICAL EQUIPMENT SHOWING | | | THE LISTING. 110.3 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-06-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-06-04 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-06-04 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-04-06 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-04-06 |
Time |
15:15 |
Sent To |
B |
|
| Notes |
| 2018-04-06 15:16:04 | IN HISTORIC DISTRICT REQUIRES COA. FHM SPOKE TO | | | DESIGNER, WILL SUBMIT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-06-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-20 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-06-19 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2018-06-20 11:44:05 | GIVEN TO JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-06-07 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-07 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-05-22 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2018-05-23 13:30:53 | RESUB ROUTED TO HISTORIC INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-04-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-04-10 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-04-02 |
Time |
09:45 |
Sent To |
I |
|
| Notes |
| 2018-04-03 09:46:12 | ROUTED TO HISTORIC INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-06-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-06-04 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-06-04 |
Time |
14:16 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-04-06 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-04-06 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2018-04-06 15:17:26 | BUILDINGS CANNOT BE CONNECTED WITH SOLID ROOF AS IS | | | ACHEIVED WHEN LOUVERS ARE IN CLOSED POSITION. |
|
|