Plan Review Details - Permit 18031323
Plan Review Stops For Permit 18031323
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-06-08 Cont ID  
Sent By cthroop Date 2018-06-08 Time 13:19 Rev Time 0.00
Received By cthroop Date 2018-06-08 Time 11:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-04-18 Cont ID  
Sent By cthroop Date 2018-04-18 Time 13:05 Rev Time 0.00
Received By cthroop Date 2018-04-18 Time 11:10 Sent To  
Notes
2018-04-18 13:17:52BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. JURISDITION HAVING AUTHORITY IS THE CITY OF WEST
 PALM BEACH. REF. PLAN PAGE T-1.
 2. PROVIDE DESIGN WIND LOADS FOR PROPOSED ANTENNA'S PER
 FBC CHPT. 16, SECTION 1603.1.4.
 3. PROVIDE FASTENER SCHEDULE BASED ON DESIGN WIND
 LOADS.
 4. DETERMINATION OF WIND LOADS SHALL BE PER FBC CHPT.
 16, SECTION 1609.1.
  
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE 2017
 FLORIDA BUILDING CODE, 6TH EDITION.
  
 FBC 107.3.5.1.1(8) ? PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-CHAPTER 16
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 1609.1 APPLICATIONS.
  
 BUILDINGS, STRUCTURES AND PARTS THEREOF SHALL BE
 DESIGNED TO WITHSTAND THE MINIMUM WIND LOADS PRESCRIBED
 HEREIN. DECREASES IN WIND LOADS SHALL NOT BE MADE FOR
 THE EFFECT OF SHIELDING BY OTHER STRUCTURES. ALL
 EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF
 RESISTING THE DESIGN PRESSURES SPECIFIED FOR WALLS FOR
 COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH
 SECTION 1609.1.1. MANUFACTURED SOFFITS SHALL BE LABELED
 IN ACCORDANCE WITH SECTION 1709.10 OF THIS CODE.
 1609.1.1 DETERMINATION OF WIND LOADS.
 WIND LOADS ON EVERY BUILDING OR STRUCTURE SHALL BE
 DETERMINED IN ACCORDANCE WITH CHAPTERS 26 TO 30 OF ASCE
 7 OR PROVISIONS OF THE ALTERNATE ALL-HEIGHTS METHOD IN
 SECTION 1609.6. WIND SHALL BE ASSUMED TO COME FROM ANY
 HORIZONTAL DIRECTION AND WIND PRESSURES SHALL BE
 ASSUMED TO ACT NORMAL TO THE SURFACE CONSIDERED.
 EXCEPTIONS:
 1.SUBJECT TO THE LIMITATIONS OF SECTION 1609.1.1.1, THE
 PROVISIONS OF ICC 600 SHALL BE PERMITTED FOR APPLICABLE
 GROUP R-2 AND R-3 BUILDINGS.
 2.SUBJECT TO THE LIMITATIONS OF SECTION 1609.1.1.1,
 RESIDENTIAL STRUCTURES USING THE PROVISIONS OF AWC
 WFCM.
 3.SUBJECT TO THE LIMITATIONS OF SECTION 1609.1.1.1,
 RESIDENTIAL STRUCTURES USING THE PROVISIONS OF AISI
 S230.
 4.DESIGNS USING NAAMM FP 1001.
 5.DESIGNS USING TIA-222 FOR ANTENNA-SUPPORTING
 STRUCTURES AND ANTENNAS, PROVIDED THE HORIZONTAL EXTENT
 OF TOPOGRAPHIC CATEGORY 2 ESCARPMENTS IN SECTION
 2.6.6.2 OF TIA-222 SHALL BE 16 TIMES THE HEIGHT OF THE
 ESCARPMENT. DESIGN USING THIS STANDARD SHALL BE
 PERMITTED FOR COMMUNICATION TOWER AND STEEL ANTENNA
 SUPPORT STRUCTURES.
 6.WIND TUNNEL TESTS IN ACCORDANCE WITH ASCE 49 AND
 SECTIONS 31.4 AND 31.5 OF ASCE 7.
 7.WIND LOADS FOR SCREEN ENCLOSURES SHALL BE DETERMINED
 IN ACCORDANCE WITH SECTION 2002.4.
 8.EXPOSED MECHANICAL EQUIPMENT OR APPLIANCES FASTENED
 TO A ROOF OR INSTALLED ON THE GROUND IN COMPLIANCE WITH
 THE CODE USING RATED STANDS, PLATFORMS, CURBS, SLABS,
 WALLS, OR OTHER MEANS ARE DEEMED TO COMPLY WITH THE
 WIND RESISTANCE REQUIREMENTS OF THE 2007 FLORIDA
 BUILDING CODE, AS AMENDED. FURTHER SUPPORT OR ENCLOSURE
 OF SUCH MECHANICAL EQUIPMENT OR APPLIANCES IS NOT
 REQUIRED BY A STATE OR LOCAL OFFICIAL HAVING AUTHORITY
 TO ENFORCE THE FLORIDA BUILDING CODE.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-06-08 Cont ID  
Sent By jleahy Date 2018-06-08 Time 10:32 Rev Time 0.00
Received By jleahy Date 2018-06-08 Time 10:32 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-04-18 Cont ID  
Sent By jleahy Date 2018-04-18 Time 10:03 Rev Time 0.00
Received By jleahy Date 2018-04-18 Time 10:03 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-06-08 Cont ID  
Sent By cthroop Date 2018-06-08 Time 13:19 Rev Time 0.00
Received By cthroop Date 2018-05-30 Time 15:24 Sent To I
Notes
2018-05-31 15:24:19RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-04-18 Cont ID  
Sent By cthroop Date 2018-04-18 Time 13:17 Rev Time 0.00
Received By cthroop Date 2018-03-29 Time 11:43 Sent To I
Notes
2018-03-30 11:43:57ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 2 Status P Date 2018-06-07 Cont ID  
Sent By mcruz Date 2018-06-07 Time 13:48 Rev Time 0.00
Received By mcruz Date 2018-06-07 Time 13:47 Sent To E
Notes
2018-06-07 13:47:57NO WIRELESS COMMUNITCATION APPLICATION APPROVAL NEEDED.
 APPROVED BY CITY SCAPE. SEE ATTACHED LETTER.

Review Stop Z ZONING
Rev No 1 Status P Date 2018-04-12 Cont ID  
Sent By aaponte Date 2018-04-12 Time 10:20 Rev Time 0.00
Received By aaponte Date 2018-04-12 Time 10:20 Sent To E
Notes
2018-04-12 10:21:21NO WIRELESS COMMUNITCATION APPLICATION APPROVAL NEEDED.
 APPROVED BY CITY SCAPE. SEE ATTACHED LETTER.