| Plan Review Stops For Permit 18031052 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-02-15 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-15 |
Time |
16:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-21 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-21 |
Time |
17:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-11-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-11-01 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-11-01 |
Time |
16:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-02 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-02 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-04-06 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-04-05 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2018-04-06 15:21:08 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | | | | 561-805-6718 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2017 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION / FRC FLORIDA RESIDENTIAL CODE | | | 2017 6TH EDITION | | | | | | 1. FAIR HOUSING DESIGN MANUAL | | | | | | A) KITCHEN ISLAND DOES NOT HAVE 40 INCH CLEARANCE ON | | | TWO SIDES. | | | | | | B. PROVIDE 32 INCHES CLEAR AT BATHROOM DOORS. | | | | | | C. IN THE FAIR HOUSING DESIGN MANUAL CHAPTER 7 SELECT | | | WHETHER YOU WILL BE USING A OR B SPECIFICATIONS WHEN | | | DESIGNING THE BATHROOMS. SHOW THIS ON THE PLANS AND | | | ADJUST LAYOUT ACCORDINGLY. | | | | | | 2. DOORS | | | | | | A. DOOR 111 NOT SHOWN ON SCHEDULE. | | | | | | B. PROVIDE INFORMATION ON DOOR 101C. ROLL DOWN SMOKE | | | DOOR IF USED. NOTE, SINCE THE ELEVATOR IS PRESSURIZED | | | THIS DOOR IS NOT REQUIRED. | | | | | | 3. PROVIDE UNDERLAYMENT USED FOR WOOD FLOOR IN ROOM | | | 121A GYM. IF PLYWOOD UNDERLAYMENT IS USED SHOW | | | COMPLIANCE WITH FBC 603.1 COMBUSTIBLE MATERIALS. | | | | | | 4. PROVIDE THE FOLLOWING FLOOR UNDERLAYMENT SOUND | | | PROOFING INFORMATION. | | | | | | STRUCTURAL BORNE SOUND TEST HAS BEEN RECEIVED. | | | | | | SUFFOLK CONSTRUCTION TO CONDUCT SITE TESTING FOR | | | COMPLIANCE WITH THE 2010 FBC-B SECTIONS: | | | | | | FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND. | | | FBC-B 2010 1207.2 AIR-BORNE SOUND. | | | FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. | | | THE SOUND TESTS WILL BE CONDUCTED ON A 10 INCH CONCRETE | | | SLAB UNDER THE MAIN PERMIT (15111020) AND SUBMITTED AS | | | SOON AS RESULTS ARE PRINTED AND REVIEWED BY THE | | | DESIGNER OF RECORD. | | | NOTE: SITE TESTING FOR FLOOR INSULATION WILL REQUIRE | | | THE APPLICANT TO REQUEST (IN WRITING) UNDER THE 2010 W. | | | P. B. ADMINISTRATIVE CODE SECTION 104.11 ALTERNATE | | | MATERIALS, DESIGN AND METHODS OF CONSTRUCTION FOR THE | | | SOUND UNDERLAYMENT. THE LETTER SHOULD BE MADE OUT TO | | | THE BUILDING OFFICIAL ROBERT BROWN. | | | | | | SHEET: FINISHES. UNIT: | | | FLOOR FINISHES. BLDG TYPE: TYPE I/ TYPE II FLOOR | | | INSULATION (FBC-B 2010) | | | FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL | | | NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR | | | ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE | | | QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A | | | 10 INCH CONCRETE FLOOR ASSEMBLY AS PER PLAN OR PROVIDE | | | ONSITE TESTING TO THE LISTED BELOW ASTM STANDARDS: | | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | | | | 1A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | 1B) FBC-B 2014 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 1C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-08-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-24 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-24 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-05-04 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-05-04 |
Time |
06:32 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-05-04 |
Time |
06:32 |
Sent To |
|
|
| Notes |
| 2018-05-04 10:18:38 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGE E-1.1 | | | | | | NOTE #4 UPDATE CODE EDITIONS | | | | | | NOTE #62 UPDATE NOTE TO REFLECT NEC CODE 2014 ARC | | | FAULTS IN KITCHEN AND LAUNDRY AREAS | | | ALL 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH | | | CIRCUITS SUPPLYING OUTLETS IN DWELLING UNIT KITCHENS, | | | LAUNDRY ROOMS, | | | FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, | | | LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, | | | CLOSETS, HALLWAYS, | | | OR SIMILAR AREAS OR ROOMS, SHALL HAVE AFCI PROTECTION. | | | NEC 210.12; FBC RE3902.16 | | | | | | PAGE E-2.1 | | | | | | OUTLET SPACING SEEMS TO BE DEFICIENT IN MOST ROOMS | | | E3901.2.1 SPACING. RECEPTACLES SHALL BE INSTALLED SO | | | THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR | | | LINE OF ANY | | | WALL SPACE IS MORE THAN 6 FEET (1829 MM), FROM A | | | RECEPTACLE OUTLET. [210.52(A)(1)] | | | E3901.2.2 WALL SPACE. | | | AS USED IN THIS SECTION, A WALL SPACE SHALL INCLUDE THE | | | FOLLOWING: [210.52(A)(2)] | | | 1. 1.ANY SPACE THAT IS 2 FEET (610 MM) OR MORE IN | | | WIDTH, INCLUDING SPACE MEASURED AROUND CORNERS, AND | | | THAT IS | | | UNBROKEN ALONG THE FLOOR LINE BY DOORWAYS AND SIMILAR | | | OPENINGS, FIREPLACES, AND FIXED CABINETS. | | | 2. 2.THE SPACE OCCUPIED BY FIXED PANELS IN EXTERIOR | | | WALLS, EXCLUDING SLIDING PANELS. | | | 3. 3.THE SPACE CREATED BY FIXED ROOM DIVIDERS SUCH AS | | | RAILINGS AND FREESTANDING BAR-TYPE COUNTERS | | | | | | | | | OUTLETS MISSING ON BALCONY | | | E3901.7 OUTDOOR OUTLETS. | | | NOT LESS THAN ONE RECEPTACLE OUTLET THAT IS READILY | | | ACCESSIBLE FROM GRADE LEVEL AND LOCATED NOT MORE THAN 6 | | | FEET, 6 INCHES | | | (1981 MM) ABOVE GRADE, SHALL BE INSTALLED OUTDOORS AT | | | THE FRONT AND BACK OF EACH DWELLING UNIT HAVING DIRECT | | | ACCESS TO | | | GRADE LEVEL. BALCONIES, DECKS, AND PORCHES THAT ARE | | | ACCESSIBLE FROM INSIDE OF THE DWELLING UNIT SHALL HAVE | | | AT LEAST ONE | | | RECEPTACLE OUTLET INSTALLED WITHIN THE PERIMETER OF THE | | | BALCONY, DECK, OR PORCH. THE RECEPTACLE SHALL BE | | | LOCATED NOT MORE | | | THAN 6 FEET, 6 INCHES (1981 MM) ABOVE THE BALCONY, | | | DECK, OR PORCH SURFACE. [210.52(E)] | | | | | | KITCHEN AND LAUNDRY AREAS NEED ARC FAULT PROTECTION | | | ALL 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH | | | CIRCUITS SUPPLYING OUTLETS IN DWELLING UNIT KITCHENS, | | | LAUNDRY ROOMS, | | | FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, | | | LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, | | | CLOSETS, HALLWAYS, | | | OR SIMILAR AREAS OR ROOMS, SHALL HAVE AFCI PROTECTION. | | | NEC 210.12; FBC RE3902.16 | | | | | | PAGE E-4.1 | | | | | | PANEL SCHEDULES NEED TO REFLECT NEW AFCL/GFCI | | | PROVISIONS | | | | | | NEED TO SUBMIT FAULT CURRENT CALCULATIONS | | | | | | NEED TO SUBMIT A LOAD CALCULATION | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, | | | IT IS HELPFUL TO PROVIDE A RESPONSE LETTER ADDRESSING | | | EACH ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED | | | PAGES INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6713 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-08-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-08-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-08-07 |
Time |
13:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-04-11 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-04-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-04-11 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2018-04-11 12:02:17 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) COVER SHEET - THE ADDRESS IN THE TITLE BLOCK | | | INDICATES 1112 S FLAGLER. THE ADDRESS OF THE BUILDING | | | IS 1100 S FAGLER. | | | | | | PLEASE REVIEW AND CORRECT OR JUSTIFY. | | | | | | | | | | | | 2) THERE IS SMOKEGAURD SMOKE CURTAIN INDICATED AT THE | | | ELEVATOR LOBBY. | | | | | | THIS OPENING ALSO FUNCTION A AN EXIT/EXIT ACCESS TO | | | THIS RESIDENCE. HOW WILL THIS OPENING/CURTAIN FUNCTION | | | AS AN EXIT/EXIT ACCESS IN THE EVENT IT ACTIVATES AND IS | | | IN THE DOWN POSITION? | | | | | | ADDITIONALLY, THE BUREAU HAS TESTED PREVIOUS PROPOSED | | | SIMILAR CURTAINS THAT FAIL TO STAY SECURED DUE TO | | | PRESSURIZATION OF OTHER LIFE SAFETY SYSTEMS. HAS THE | | | PRESSURIZATION OF THE ELEVATOR BEEN CONSIDERED WITH THE | | | EOR OF THIS BUILDING. | | | | | | PLEASE REVIEW AND PROVIDE DETAILS | | | | | | | | | | | | 3) SHEET F O.1 - THE FIRE SPRINKLER DRAWINGS APPEAR TO | | | HAVE AN ENGINEER STAMP AND/OR SEAL. THERE CAN BE ONLY | | | ONE ENGINEEER OF RECORD FOR THE SPRINKLER SYSTEM. | | | | | | DOES THIS STAMPED SET CONFLICT WITH THE ORIGINAL EOR | | | STAMP AND DOES THE EOR APPROVE OF THIS DESIGN. | | | | | | PLEASE REVIEW, CORRECT OR JUSTIFY WITH DETAILS. | | | | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2018-09-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-09-04 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-09-04 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2018-09-04 10:14:21 | PROVISO: | | | SHALL PROVIDE BEFORE ROUGH INSPECTIONS | | | 1. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION | | | GUIDES FOR COOK TOP. | | | 2. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION | | | GUIDES FOR DRYER VENT. | | | 3. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION | | | GUIDES FOR MASTER TUB DRAIN. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-05-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-05-16 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-05-16 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2018-05-16 11:43:43 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. P-2.2 SHOWS THE G/# RISER 3/4 NG TO UNIT SHOWS | | | 104 CFH THE TOTAL BTU LOAD ON THE ISOMETRIC IS ONLY 66 | | | CFH PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. SHT P-2.2 SHOWS THE PIPING TO THE DRYER AS 1/2" THE | | | ISOMETRIC ON SHT P-3.1 SHOWS 3/4" PLEASE CLARIFY. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 3. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304 | | | | | | | | | 4. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT AND REGULATORS TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. | | | 402.2 ALSO PROVIDE INSTALLATION GUIDE FOR DRYER VENT. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-02-15 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-15 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-02-11 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-01-21 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-21 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-11-27 |
Time |
15:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-11-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-10-01 |
Time |
10:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-09-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-08-03 |
Time |
13:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-05-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-05-16 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-03 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-04-06 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-04-06 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2019-02-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-02-11 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-02-08 |
Time |
17:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-12-21 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-12-21 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2018-12-21 13:02:20 | 3RD REVIEW FBC-2010 MECHANICAL | | | PERMIT #18031052 | | | 12/21/18 | | | | | | PLAN REVIEW RESULTS: DENIED. (PLAN REVIEW I N PROGRESS, | | | DO NOT PRINT). | | | | | | 1) THE SPECS FOR THE DOWN DRAFT SYSTEMS DO NOT INDICATE | | | SYSTEMS ARE DESIGNED FOR RECIRCULATION, AND BASED ON | | | THE 1000 CFM MAXIMUM EXHAUST RATINGS, MAKEUP AIR WILL | | | BE REQUIRED PER SECTION 505.2 FBC M. | | | | | | 2) SHEETS M2.1 AND A4.6: THE PLANS DO NOT SHOW THE | | | KITCHEN EXHAUST SYSTEMS ABOVE THE COOKTOPS ARE IN | | | COMPLIANCE WITH SEVERAL ITEMS LISTED UNDER SECTION | | | 505.3 FBC M- SEE BELOW. | | | | | | 505.3 COMMON EXHAUST SYSTEMS FOR DOMESTIC KITCHENS | | | LOCATED IN MULTISTORY STRUCTURES. | | | | | | WHERE A COMMON MULTISTORY DUCT SYSTEM IS DESIGNED AND | | | INSTALLED TO CONVEY EXHAUST FROM MULTIPLE DOMESTIC | | | KITCHEN EXHAUST SYSTEMS, THE CONSTRUCTION OF THE SYSTEM | | | SHALL BE IN ACCORDANCE WITH ALL OF THE FOLLOWING: | | | | | | 5.THE EXHAUST FAN MOTOR DESIGN SHALL BE IN ACCORDANCE | | | WITH SECTION 503.2. PLEASE REVIEW SECTION 503.2 AND | | | PROVIDE MANUFACTURER'S SPECIFICATIONS FOR EF-C WITH | | | INFORMATION INDICATING COMPLIANCE. | | | | | | 6. THE EXHAUST FAN MOTOR SHALL BE LOCATED OUTSIDE OF | | | THE AIRSTREAM. | | | | | | 7.THE EXHAUST FAN SHALL RUN CONTINUOUSLY, AND SHALL BE | | | CONNECTED TO A STANDBY POWER SOURCE. | | | | | | 8. EXHAUST FAN OPERATION SHALL BE MONITORED IN AN | | | APPROVED LOCATION AND SHALL INITIATE AN AUDIBLE OR | | | VISUAL SIGNAL WHEN THE FAN IS NOT IN OPERATION. | | | | | | 3) SECTIONS 917.1 & 017.2 REQUIRE UL LISTING AND | | | LABELING FOR THE MIELE COOKING APPLIANCES, HOWEVER I'M | | | NOT SEEING ANY EVIDENCE OF UL LISTING IN THE SUBMITTED | | | SPEC SHEETS. | | | | | | 4) AS PREVIOUSLY NOTED, THE DRYER BOOSTER FAN SPECS DO | | | NOT INDICATE THE FAN IS LISTED AND LABELED FOR USE WITH | | | A CLOTHES DRYER- SECTION 504.6.4.1 FBC M. | | | | | | 5) M2.1: PLEASE MODIFY NOTE #26 TO INDICATE THE DRYER | | | BOOSTER FAN WILL ALSO BE ENCLOSED IN THE PLENUM RATED | | | EXHAUST CHASE AND PROVIDE CONSTRUCTION DETAILS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2018-11-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-11-06 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-11-06 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2018-11-06 17:37:33 | 2ND REVIEW FBC-2010 MECHANICAL | | | PERMIT #18031052 | | | 11/6/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE AC CALCULATION PRINTOUT IS INDICATING MIAMI AS | | | THE PROJECT LOCATION. PLEASE PROVIDE CALCULATIONS USING | | | THE CORRECT LOCATION, AND INCLUDE THE ADDRESS AND UNIT | | | NUMBER ON THE CALCULATION PRINTOUT. | | | | | | 2) M2.1: SMOKE DETECTORS ARE REQUIRED IN BOTH THE | | | SUPPLY AND THE RETURN SYSTEMS OF THE HP'S- SECTION | | | 606.2 FBC M. | | | | | | 3) M2.1: PROVIDE THE RETURN OPENING DIMENSIONS AT EACH | | | HP CLOSET- SECTION 601.4 FBC M. | | | | | | 4) M2.1: THERE IS INSUFFICENT INFORMATION AND DETAILS | | | ON THE PLAN TO SHOW COMPLIANCE FOR THE REQUIRED KITCHEN | | | EXHAUST SYSTEMS: | | | | | | A) PLEASE PROVIDE ENLARGED KITCHEN EXHAUST DETAILS ON | | | THE PLAN SHOWING THE COOKTOP DOWNDRAFT EXHAUST DUCT | | | RUNS AND TERMINATION LOCATIONS. CLARIFY IF TWO SYSTEMS | | | WILL BE INSTALLED- ONE FOR THE GAS-FIRED COOKTOP AND | | | ONE FOR THE ELECTRIC COOKTOP. SPECS HAVE BEEN SUBMITTED | | | FOR EACH HOWEVER THE PLAN APPEARS TO SHOW ONLY ONE | | | COOKTOP. | | | | | | B) THE COMB-OVEN, SPEED OVEN, AND CONVECTION OVEN EACH | | | REQUIRE AN EXHAUST VENTILATION SYSTEM HOWEVER NO SPECS | | | FOR THE VENTS HAVE BEEN SUBMITTED AND NO DETAILS HAVE | | | BEEN PROVIDED ON THE PLAN. | | | | | | C) PLEASE REFER TO TABLE 403.3 WHICH REQUIRES AN | | | EXHAUST VENTILATION RATE OF 25 CFMS PER SF. FOR | | | CONTINUOUS VENTILATION, AND 100 CFMS PER SF. FOR | | | INTERMITTENT VENTILATION. | | | | | | 5) THE DRYER BOOSTER FAN SPECS DO NOT INDICATE THE FAN | | | IS LISTED AND LABELED FOR USE WITH A CLOTHES DRYER- | | | SECTION 504.6.4.1 FBC M | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-09-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-09-05 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-09-05 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2018-09-05 17:04:27 | 1ST REVIEW FBC-2010 MECHANICAL | | | PERMIT #18031052 | | | 9/5/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | PLEASE NOTE THAT ALL APARTMENT BUILDOUTS WILL BE | | | DESIGNED UNDER THE 2010 FLORIDA BUILDING CODES UNTIL | | | WHICH TIME THE ENTIRE BUILDING RECEIVES A CERTIFICATE | | | OF OCCUPANCY. | | | | | | 1) PLEASE REPLACE THE ENERGYGAUGE 2017 COMPLIANCE | | | SUBMITTAL WITH THE 2010 VERSION AND PROVIDE PIPING | | | SYSTEM COMPLIANCE DATA THAT IS MISSING FROM THE FORM. | | | | | | 2) M2.1: SHOW THE LOCATION OF THE O/A DUCT THAT IS | | | SUPPLYING THE UNITS VIA THE RETURN AIR PLENUM, | | | | | | 3) M2.1: DUE TO THE FACT THAT THE AC CLOSETS ARE | | | SHARING A COMMON PLENUM SMOKE DETECTORS SHALL BE | | | PROVIDED IN THE RETUN AIR PLENUM IN ACCORDANCE WITH | | | SECTION 606.2.2 FBC M. | | | | | | 4) M2.1: REGARDING THE INTUMESCENT PAINT ON THE AC | | | CLOSET DOORS, IT HAS BEEN DETERMINED THAT THE ENGINEER | | | OF RECORD SHALL BE RESPONSIBLE FOR INSPECTING AND | | | CERTIFYING THE APPLICATION PROCESS. PLACE A NOTE ON THE | | | PLAN ACCORDINGLY. | | | | | | 5) M2.1: THE RESPONSE NARRATIVE FROM THE JOHNSON GROUP | | | IS REFERENCING SHEET AXX FOR THE DRYER ENCLOSURE | | | DETAIL. I WAS NOT ABLE TO LOCATE THE SHEET OR DETAIL. | | | | | | 6) M2.1: THE RESPONSE NARRATIVE FROM THE JOHNSON GROUP | | | IS REFERENCING A DIMENSIONED, SEGMENTED DRAWING OF THE | | | DRYER EXHAUST DUCT WHICH I WAS UNABLE TO LOCATE. PLEASE | | | PROVIDE THE DRAWING. | | | | | | 7) M2.1 : CLARIFY THE NEED FOR THE DRYER EXHAUST | | | BOOSTER FAN. PER THE EQUIVALENT LENGTH TABLE, THE 120 | | | FT. RUN DOES NOT EXCEED THE 125 FT. MAXIMUM RUN ALLOWED | | | BY THE MANUFACTURER. IN ADDITION, PLEASE CONTACT FIRE | | | CHIEF PETER LEDUC FOR PERMISSION TO INSTALL THE BOOSTER | | | FAN. IF PERMITTED, AN ACCESS PANEL WILL BE REQUIRED FOR | | | SERVICE AND REPLACEMENT OF THE FAN- SECTION 306.1. | | | | | | 8) M2.1: THE COMBUSTION AIR CALCULATION TABLE LISTS THE | | | KITCHEN AT 3860 SQ. FT. WHICH CLEARLY FROM THE DRAWINGS | | | IT IS NOT. PLEASE PROVIDE AN ACCURATE CALCULATION. | | | | | | 9) THE REQUESTED PRODUCT DATA SHEETS FOR THE GAS FIRED | | | APPLIANCES AND DOWN DRAFT EXHAUST SYSTEM WERE NOT | | | PROVIDED. PLEASE NOTE THAT AN EXHAUST HOOD MAY BE | | | REQUIRED FOR THE OVENS PER SECTION 507.2.2 FBC M. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-05-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-05-09 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-05-08 |
Time |
17:40 |
Sent To |
|
|
| Notes |
| 2018-05-09 10:18:37 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18031052 | | | 4/9/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M2.1: THE SE-2 DUCT IS NOT PERMITTED TO | | | PENETRATE INTO THE INTERIOR STAIRWELL ENCLOSURE- | | | SECTION 1023.5 FBC-17 BUILDING. | | | | | | 2) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | | HEAT PUMPS. THE CALCULATIONS SUBMITTED UNDER THE MAIN | | | BUILDING PERMIT ARE NOT VALID FOR THIS NEW INTERIOR | | | BUILDOUT UNDER NEW OWNERSHIP AND SEPARATE PERMIT - | | | SECTION C403.2.1 FBC-17 ENERGY CONSERVATION. | | | | | | 3) PROVIDE AN ENERGY COMPLIANCE REPORT. THE | | | CALCULATIONS SUBMITTED UNDER THE MAIN BUILDING PERMIT | | | ARE NOT VALID FOR THIS NEW INTERIOR BUILDOUT UNDER NEW | | | OWNERSHIP AND SEPARATE PERMIT SECTION C101.5 | | | | | | 6) PROVIDE MINIMUM VENTILATION CALCULATIONS FOR THE | | | SPACE IN ACCORDANCE WITH TABLE 403.1.1, AND INDICATE | | | HOW THE OUTDOOR AIR FLOW WILL BE AUTOMATICALLY | | | CONTROLLED- SEE SECTION C403.2.4.3 FBC-17 ENERGY | | | CONSERVATION. CLARIFY HOW O/A IS BEING SUPPLIED TO THE | | | HEAT PUMPS. | | | | | | 7) M2.1: A DUCT SMOKE DETECTOR IS REQUIRED IN THE | | | SUPPLY SYSTEM OF HP-G- SECTION 606.2.1. THIS | | | REQUIREMENT MAY BE WAIVED IF MANUFACTURER'S | | | SPECIFICATIONS INDICATE THE UNIT CANNOT PRODUCE OVER | | | 2000 CFMS OF SUPPLY AIR. | | | | | | 8) M2.1 & A9.1: NON-COMBUSTIBLE DOORS ARE REQUIRED FOR | | | THE AC CLOSETS IN COMPLIANCE WITH SECTION 602.2 FBC-17 | | | MECHANICAL, AND C403.2.9.2 FBC-17 ENERGY CONSERVATION. | | | | | | 10) M2.1: DRYER: A) PER NOTES #12 & 26 : PROVIDE | | | CONSTRUCTION DETAILS OR MANUFACTURER'S SPECIFICATIONS | | | FOR THE DRYER EXHAUST DUCT PLENUM ENCLOSURE- SECTION | | | 504.4. B) SUBMIT MANUFACTURER' SPECIFICATIONS FOR THE | | | DRYER THAT LISTS THE MAXIMUM LENGTH OF THE EXHAUST DUCT | | | RUN- 504.8.4. C) PROVIDE A DRAWING THAT SHOWS THE TOTAL | | | RUN LENGTH OF THE EXHAUST DUCT FROM THE DRYER OUTLET | | | | | | TO THE SHAFT INCLUDING SEGMENTED LENGTH MEASUREMENTS, | | | AND THE EQUIVALENT LENGTHS OF THE ELBOWS- 504.8.4. D) | | | INDICATE WHICH SUBDUCT DETAIL ON SHEET M2.4 IS | | | APPLICABLE TO THE DRYER EXHAUST. E) PROVIDE MAKEUP AIR | | | FOR THE DRYER PER SECTION 504.6. | | | | | | 11) M2.1: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | COOKTOPS, THE OVENS, AND THE RECIRCULATING DOWN DRAFT | | | EXHAUST SYSTEMS. NO HOODS ARE SHOWING ON THE PLANS FOR | | | THE OVENS, HOWEVER THEY MAY BE REQUIRED PER | | | MANUFACTURER'S SPECIFICATIONS. PLEASE NOTE THAT | | | COMMERCIAL COOKING APPLIANCES ARE NOT PERMITTED FOR USE | | | IN DWELLING UNITS- SECTION 917.2 FBC-17 MECHANICAL, AND | | | | | | 623.3 FBC-17 FUEL GAS. | | | | | | 12) M2.1 FOR GAS-FIRED COOKING APPLIANCES, INDICATE HOW | | | COMBUSTION AIR IS BEING PROVIDED AND PROVIDE | | | CALCULATIONS- SECTION 304 FBC-17 FUEL GAS. | | | | | | 13) M2.1, MASTER BATH 133: THE PLAN DOES NOT CLEARLY | | | SHOW HOW THE EXHAUST SYSTEMS ARE WORKING IN BATHS 134A | | | AND 135A. IT APPEARS THAT THE EF-B'S ARE CONNECTING TO | | | THE RETURN AIR PLENUM PER NOTE #6 , HOWEVER NOTE #23 | | | INDICATES THE RETURN GRILLS ARE PROVIDED OUTDOOR AIR. | | | A) REFER TO FOOTNOTE G TABLE 403.3 WHICH LIMITS | | | RECIRCULATION OF AIR FROM THE BATHROOMS TO 10% OF THE | | | TOTAL | | | | | | SUPPLY AIR PROVIDED TO THE SPACES. THE PLAN APPEARS TO | | | INDICATE NON-COMPLIANCE. | | | | | | 14) M2.1: EXHAUST IS REQUIRED FOR BATHROOMS 119B, 120B, | | | AND 121B. THE PLAN SHOWS EXHAUST PROVIDED ONLY FOR THE | | | SHOWERS. | | | | | | 15) M2.4: PLEASE INDICATE WHICH OF THE SUBDUCT DETAILS | | | IS FOR THE TOILET EXHAUST. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-09-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-09-04 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-09-02 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2018-09-04 10:13:44 | PROVISO: | | | SHALL PROVIDE BEFORE ROUGH INSPECTIONS | | | 1. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION | | | GUIDES FOR COOK TOP. | | | 2. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION | | | GUIDES FOR DRYER VENT. | | | 3. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION | | | GUIDES FOR MASTER TUB DRAIN. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-05-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-05-16 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-05-15 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2018-05-16 11:29:14 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THIS BUILDING IS REQUIRED TO COMPLY WITH THE FAIR | | | HOUSING ACT PLEASE INDICATE ON THE PLAN WHICH DESIGN | | | DOCUMENT THAT WAS USED IN DESIGNING THIS UNIT TO COMPLY | | | WITH FHA . PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. PLEASE INDICATE ON THE PLAN WHICH BATHROOM OR | | | BATHROOMS ARE USABLE AND WHICH DESIGN SPECIFICATION A | | | OR B THAT WAS USED TO COMPLY WITH FHA REQUIREMENTS # 6 | | | +7 | | | | | | 3. PLEASE PROVIDE A ENLARGED FLOOR PLAN SHOWING THE | | | REQUIRED CLEAR FLOOR SPACE FHA REQUIREMENTS # 7 | | | | | | 4. PROVIDE ELEVATION DETAILS SHOWING MOUNTING HEIGHTS | | | FOR THE GRAB BAR BACKING PER FHA REQUIREMENT # 6 | | | | | | 5. SHT. P-3.2 THE DETAIL FOR THE KITCHEN AND PANTRY | | | SHOWS A STACK THAT IS NOT LABELED OR SIZED IT HAS A | | | CLEAN OUT BUT NO FIXTURE ITS LOCATED NEXT TO THE SK | | | PLEASE LABEL AND SIZE. PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-02-15 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-15 |
Time |
17:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2019-02-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-02-11 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-02-11 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2019-02-11 12:49:36 | 4TH REVIEW FBC-2010 MECHANICAL | | | PERMIT #18031052 | | | 2/11/19 | | | | | | 1) SHEET A4.6 NOT DIGITALLY SIGNED AND SEALED- SEE | | | PREVIOUS REVIEW COMMENT FROM 12/21/2018 BELOW. | | | | | | | | | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | NEW PAGE A4.6 IS NOT DIGITALLY SIGNED (OTHER PAGES OK). | | | | | | THE PREVIOUSLY PASSED SIGNATURE REVIEWS HAVE BEEN | | | FAILED TO PREVENT THE PERMIT FROM BEING PRINTED IN | | | ERROR. | | | | | | PROVIDE DIGITALLY SIGNED PAGES AS REQUIRED BY FLORIDA | | | STATUTE 471, 481. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-21 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-21 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2018-12-21 17:35:20 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | NEW PAGE A4.6 IS NOT DIGITALLY SIGNED (OTHER PAGES OK). | | | | | | THE PREVIOUSLY PASSED SIGNATURE REVIEWS HAVE BEEN | | | FAILED TO PREVENT THE PERMIT FROM BEING PRINTED IN | | | ERROR. | | | | | | PROVIDE DIGITALLY SIGNED PAGES AS REQUIRED BY FLORIDA | | | STATUTE 471, 481. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2018-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-02 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-02 |
Time |
17:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-04-06 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-04-06 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2018-05-09 11:35:14 | MECH DIG/SIGS OK | | | CCOLE-5/8/18 | | 2018-04-06 15:24:42 | ALL SIGNATURES OK. |
|
|