| Plan Review Stops For Permit 18030944 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-14 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-14 |
Time |
06:54 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-06-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-18 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-18 |
Time |
08:54 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-04-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-04-24 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-04-24 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2018-04-24 09:05:22 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SCOPE OF WORK ON PLANS SPECIFIES INSTALLATION OF A | | | 35KW GENERATOR. | | | 2. APPLICATION IS FOR THE INSTALLATION OF MA 30KW | | | GENERATOR. PLEASE CLARIFY. | | | 3. VALUE OF PROPOSED WORK APPEARS LOW. | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE OF | | | WORK. | | | THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. | | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | | | | CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2018-08-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-11 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-11 |
Time |
12:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-06-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-21 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-06-21 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-06-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-06 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-06-06 |
Time |
17:27 |
Sent To |
B |
|
| Notes |
| 2018-06-06 17:26:33 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | PERMIT STILL SHOWS 30 KW GENERATOR. | | | | | | | | | PLEASE INCLUDE THE COST OF THE CUSTOMER SUPPLIED | | | GENERATOR AND TRANSFER SWITCH IN THE COST OF THE JOB. | | | | | | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | . | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-04-14 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-04-14 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-04-14 |
Time |
07:26 |
Sent To |
B |
|
| Notes |
| 2018-04-16 16:02:34 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | VALUE FOR WORK SHOWN IS LOW. | | | | | | PERMIT STATES A 30KW GENERATOR AND PLANS CALL FOR A | | | 35KW | | | | | | NEED TO SUBMIT A VOLTAGE DROP CALCULATION ON THE | | | FEEDERS FROM THE GENERATOR. | | | | | | NEED TO SUBMIT A FAULT CURRENT CALCULATION FOR THE | | | EXISTING SERVICE EQUIPMENT TO BE USED IN THIS | | | INSTALLATION. | | | | | | LOAD CALCULATION FOR GENERATOR. | | | | | | WIRE SIZES SHOWN COPPER OR ALUMINUM? | | | | | | HOW DO YOU GET TO THE ROOF, STAIRWELL????? | | 2018-04-14 08:28:37 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 6TH | | | EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 6TH EDITION, PART | | | VIII ELECTRICAL | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | [email protected] | | | 561-657-1653 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2018-07-31 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-07-31 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-07-31 |
Time |
14:00 |
Sent To |
E |
|
| Notes |
| 2018-07-31 14:01:27 | SEE ALL PREVIOUS REVIEW COMMENTS BY P. LEDUC ON | | | 5/31/18. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-05-31 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-05-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-05-31 |
Time |
12:48 |
Sent To |
E |
|
| Notes |
| 2018-05-31 14:19:18 | 2ND REVIEW COMMENTS: | | | | | | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) THE PROPOSED INSTALLATION SHALL COMPLY WITH THE | | | REQUIREMENTS OF NFPA? 37 | | | | | | STANDARD FOR THE INSTALLATION AND USE OF STATIONARY | | | COMBUSTION ENGINES AND GAS TURBINES, 2015 EDITION | | | | | | PLEASE ENSURE COMPLIANCE. | | | | | | | | | 2) NO DIMENSION IS INDICATED FOR THE WIDTH FROM THE | | | EXISTING BUILDING, | | | | | | PER NFPA 37 | | | | | | 4.1.4 ENGINES LOCATED OUTDOORS. ENGINES, AND THEIR | | | WEATHERPROOF | | | HOUSINGS, IF PROVIDED, THAT ARE INSTALLED OUTDOORS | | | SHALL | | | BE LOCATED AT LEAST 1.5 M (5 FT) FROM OPENINGS IN WALLS | | | AND AT | | | LEAST 1.5 M (5 FT) FROM STRUCTURES HAVING COMBUSTIBLE | | | WALLS. A | | | MINIMUM SEPARATION SHALL NOT BE REQUIRED WHERE EITHER | | | OF THE | | | FOLLOWING CONDITIONS EXIST: | | | (1) ALL WALLS OF THE STRUCTURE THAT ARE CLOSER THAN 1.5 | | | M (5 FT) | | | FROM THE ENGINE ENCLOSURE HAVE A FIRE RESISTANCE RATING | | | OF | | | AT LEAST 1 HOUR. | | | (2)*THE WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF | | | NONCOMBUSTIBLE | | | MATERIALS AND IT HAS BEEN DEMONSTRATED THAT A FIRE | | | WITHIN THE ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | | MATERIALS | | | OUTSIDE THE ENCLOSURE. | | | | | | PLEASE ENSURE COMPLIANT SEPARATION AND/OR FIRE | | | RESISTNACE RATING. | | | | | | 3) THERE IS NO INDICATION OF COMPLAINCE WITH NFPA 54 | | | | | | PER NFPA 37 | | | | | | 5.1* GAS PIPING. | | | 5.1.1 GAS PIPING SHALL BE INSTALLED IN ACCORDANCE WITH | | | THE | | | FOLLOWING METHODS: | | | (1) ALL FUEL GAS SYSTEMS AT SERVICE PRESSURES EQUAL TO | | | OR LESS | | | THAN A GAUGE PRESSURE OF 860 KPA (GAUGE PRESSURE OF | | | 125 PSI) SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 54, | | | NATIONAL FUEL GAS CODE. | | | (2) ALL FUEL GAS SYSTEMS AT SERVICE PRESSURES IN EXCESS | | | OF A | | | GAUGE PRESSURE OF 860 KPA (GAUGE PRESSURE OF 125 PSI), | | | OTHER THAN LP-GAS SYSTEMS, SHALL BE INSTALLED IN | | | ACCORDANCE | | | WITH ANSI/ASME B31.3, PROCESS PIPING. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-04-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-04-09 |
Time |
13:01 |
Sent To |
E |
|
| Notes |
| 2018-04-09 14:37:32 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) THE PROPOSED INSTALLATION SHALL COMPLY WITH THE | | | REQUIREMENTS OF NFPA? 37 | | | | | | STANDARD FOR THE INSTALLATION AND USE OF STATIONARY | | | COMBUSTION ENGINES AND GAS TURBINES, 2015 EDITION | | | | | | PLEASE ENSURE COMPLIANCE. | | | | | | | | | 2) NO DIMENSION IS INDICATED FOR THE WIDTH FROM THE | | | EXISTING BUILDING, | | | | | | PER NFPA 37 | | | | | | 4.1.4 ENGINES LOCATED OUTDOORS. ENGINES, AND THEIR | | | WEATHERPROOF | | | HOUSINGS, IF PROVIDED, THAT ARE INSTALLED OUTDOORS | | | SHALL | | | BE LOCATED AT LEAST 1.5 M (5 FT) FROM OPENINGS IN WALLS | | | AND AT | | | LEAST 1.5 M (5 FT) FROM STRUCTURES HAVING COMBUSTIBLE | | | WALLS. A | | | MINIMUM SEPARATION SHALL NOT BE REQUIRED WHERE EITHER | | | OF THE | | | FOLLOWING CONDITIONS EXIST: | | | (1) ALL WALLS OF THE STRUCTURE THAT ARE CLOSER THAN 1.5 | | | M (5 FT) | | | FROM THE ENGINE ENCLOSURE HAVE A FIRE RESISTANCE RATING | | | OF | | | AT LEAST 1 HOUR. | | | (2)*THE WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF | | | NONCOMBUSTIBLE | | | MATERIALS AND IT HAS BEEN DEMONSTRATED THAT A FIRE | | | WITHIN THE ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | | MATERIALS | | | OUTSIDE THE ENCLOSURE. | | | | | | PLEASE ENSURE COMPLIANT SEPARATION AND/OR FIRE | | | RESISTNACE RATING. | | | | | | 3) THERE IS NO INDICATION OF COMPLAINCE WITH NFPA 54 | | | | | | PER NFPA 37 | | | | | | 5.1* GAS PIPING. | | | 5.1.1 GAS PIPING SHALL BE INSTALLED IN ACCORDANCE WITH | | | THE | | | FOLLOWING METHODS: | | | (1) ALL FUEL GAS SYSTEMS AT SERVICE PRESSURES EQUAL TO | | | OR LESS | | | THAN A GAUGE PRESSURE OF 860 KPA (GAUGE PRESSURE OF | | | 125 PSI) SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 54, | | | NATIONAL FUEL GAS CODE. | | | (2) ALL FUEL GAS SYSTEMS AT SERVICE PRESSURES IN EXCESS | | | OF A | | | GAUGE PRESSURE OF 860 KPA (GAUGE PRESSURE OF 125 PSI), | | | OTHER THAN LP-GAS SYSTEMS, SHALL BE INSTALLED IN | | | ACCORDANCE | | | WITH ANSI/ASME B31.3, PROCESS PIPING. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-13 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-08-13 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2018-08-13 17:40:01 | 08/13/18 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-06-19 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-06-19 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-06-19 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2018-06-19 16:24:30 | 06/19/2018 2ND REVIEW **DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | | | | 1. SHEET P-1 UNDER NOTES AND GAS PIPE DESIGN | | | INFORMATION ITEM 1 NEED THE CHANGE FROM 2014 FBC FG TO | | | 2017 FBC FG, PER WPB AMEND TO FBC 107.2.1. | | | | | | 2. THE MANUFACTURER'S SPECIFICATIONS FOR THE GENERATOR | | | SHALL BE ONSIDE FOR FINAL GAS INSPECTION. THE GENERATOR | | | SHALL BE LISTED AND APPROVED. NFPA 58 SEC. 5.20.1. THE | | | GENERATOR SHALL MEET THE REQUIREMENTS OF UL 2200. | | | | | | 3. NFPA 37, SECTION 4.1.4, ENGINES LOCATED OUTDOORS. | | | ENGINES, AND THEIR WEATHERPROOF HOUSINGS, IF PROVIDED, | | | THAT ARE INSTALLED OUTDOORS SHALL BE LOCATED AT LEAST 5 | | | FT. FROM OPENINGS IN WALLS AND AT LEAST 5 FT. FROM | | | STRUCTURES HAVING COMBUSTIBLE WALLS. A MINIMUM | | | SEPARATION SHALL NOT BE REQUIRED WHERE EITHER OF THE | | | FOLLOWING CONDITIONS EXIST; | | | | | | (1) ALL WALLS OF THE STRUCTURE THAT ARE CLOSER THAN 5 | | | FT. FROM THE ENGINE ENCLOSURE HAVE A FIRE RESISTANCE | | | RATING OF AT LEAST 1 HOUR. | | | | | | (2)*THE WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF | | | NONCOMBUSTIBLE MATERIALS AND IT HAS BEEN DEMONSTRATED | | | THAT A FIRE WITHIN THE ENCLOSURE WILL NOT IGNITE | | | COMBUSTIBLE MATERIALS OUTSIDE THE ENCLOSURE. | | | | | | 4. REGULATORS INSTALLED OUTDOORS SHALL BE DESIGNED, | | | INSTALLED OR PROTECTED SO THEIR OPERATION WILL NOT BE | | | AFFECTED BY THE ELEMENTS. PROVIDE DOCUMENTATION FROM | | | THE MANUFACTURER THAT THE REGULATORS ARE APPROVED FOR | | | EXTERIOR USE. NFPA 58-11 SEC. 6.8.1.5. | | | | | | 5. SHOW THE LOCATION OF ALL MP (STEP-DOWN) REGULATORS. | | | A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY | | | AHEAD OF EACH MP REGULATOR. 2017 FBC FUEL GAS SEC. | | | 409.4. | | | | | | 6. SUBMIT MANUFACTURER?S SPECIFICATION | | | SHEETS/INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH 2017 FBC FUEL GAS SEC.305.1. | | | | | | 7. SUBMIT TWO COPIES OF THE SIZING TABLE USED IN THE | | | DESIGN FOR THE GAS SYSTEM OR PLACE A NOTE ON BOTH SETS | | | OF PLANS LISTING THE SIZING TABLES FROM GAS CODES OR | | | ANOTHER STANDARD THAT WERE USED IN THE DESIGN OF THIS | | | SYSTEM 2017 FBC FUEL GAS SEC. 402.3 | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-14 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-07-24 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2018-07-25 13:59:46 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-06-19 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-06-19 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-05-21 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2018-06-16 11:51:05 | 6/16/ TO CT DESK | | | | | 2018-05-22 13:45:32 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-04-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-04-24 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-03-22 |
Time |
13:04 |
Sent To |
I |
|
| Notes |
| 2018-03-23 13:04:50 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-07-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-07-30 |
Time |
11:38 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
mc to pg |
Date |
2018-05-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-05-30 |
Time |
12:22 |
Sent To |
FIRE |
|
| Notes |
| 2018-05-30 12:22:48 | LANDSCAPE PERMIT REQUIRED | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-04-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-04-06 |
Time |
10:57 |
Sent To |
FIRE |
|
| Notes |
| 2018-04-06 10:58:08 | LANDSCAPE PERMIT REQUIRED | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] |
|
|