Plan Review Details - Permit 18030885
| Plan Review Stops For Permit 18030885 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-04-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-18 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-18 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2018-04-18 09:12:29 | ***PROVISO*** | | | | | | APPROVED ASSEMBLY WAS NOT SELECTED. ENGINEERING FOR | | | ENHANCED FASTENING WAS NOT PROVIDED, FBC BUILDING 1609. | | | | | | THIS PERMIT IS ISSUED AT APPLICANT'S RISK. AT | | | INSPECTION, PROVIDE ENGINEERING (RAS 117 CALCULATIONS). | | | THE ENGINEERING SHOULD ALSO SPECIFY THE ASSEMBLY | | | PROPOSED. | | | | | | THIS PERMIT IS BEING ISSUED WITHOUT THE REQUIRED | | | INFORMATION AS THE ROOF HAS BEEN LEAKING FOR WEEKS. | | | OWNER WAS ADVISED THAT, IF THE INSTALLATION IS NOT DONE | | | IN ACCORDANCE WITH THE CODE OR THE ENGINEERING IS NOT | | | PROVIDED, ADDITIONAL WORK OR ADDITIONAL ENGINEERING MAY | | | BE REQUIRED. | | | | | | | | | | | | INTERNAL USE ONLY RE: HISTORIC: | | | | | | SPOKE WITH F.MITTNER; SHE DOES NOT NEED TO RE-REVIEW | | | PLAN. SCOPE PROPOSED (EXISTING ROOF, ROOF STRUCTURE, | | | COLUMNS AND BEAMS TO REMAIN OR BE REPAIRED/REPLACED IN | | | SAME LOCATION AS NEEDED), WALLS INSTALLED WITHOUT | | | PERMIT TO BE REMOVED, REROOF ENTIRE BUILDING) IS OK | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-04-06 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-04-06 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2018-04-06 14:00:37 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PLAN IS INCONSISTANT WITH SCOPE OF WORK ON | | | APPLICATION. | | | 2. SOW DIRECTS THE REMOVAL OF THE ILLEGAL ADDITION. | | | 3. PLANS SHOW LEAVING THE COLUMNS AND BEAMS. | | | 4. HAVE THE ENGINEER OF RECORD DEMONSTRATE THE | | | STABILITY OF THE COLUMNS AND BEAMS WITHOUT A ROOF | | | DIAPHRAM. YOU MAY SUBMIT A SIGNED AND SEALED LETTER ON | | | HIS LETTERHEAD TO SATISFY THIS REQUIREMENT. | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-03-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-03-30 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-03-30 |
Time |
15:14 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-04-06 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-03-21 |
Time |
10:37 |
Sent To |
I |
|
| Notes |
| 2018-03-23 10:37:17 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-04-06 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-04-06 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-03-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-03-30 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-03-30 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
|