Plan Review Details - Permit 18030862
| Plan Review Stops For Permit 18030862 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-05-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-22 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-22 |
Time |
11:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-04-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-04-04 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-04-04 |
Time |
08:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-05-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-05-15 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-05-15 |
Time |
13:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-04-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-04-05 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-04-05 |
Time |
08:18 |
Sent To |
I |
|
| Notes |
| 2018-04-05 08:19:12 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS NOT ADDRESSED: | | | | | | 1. RECEPTACLES IN STORAGE AREAS REQUIRE GFCI | | | PROTECTION. PROVIDE CORRECTION. NEC 210.8; FBC RE | | | E3902.2 | | | 2. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE | | | EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC | | | RE R314.3, R315.1; WPB FBC 107.2.1 | | | 3. AFCI STATEMENT ON PLAN NEEDS TO BE CORRECTED. PER | | | THE 2014 NEC: "ALL BRANCH CIRCUITS THAT SUPPLY | | | 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS | | | INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, | | | LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, | | | SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, | | | LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI | | | PROTECTED." PROVIDE CORRECTION. NEC 210.12; FBC RE | | | E3902.16 | | | 4. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC EC R404.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-04-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-04-03 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-04-03 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2018-04-03 14:46:47 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. RECEPTACLES IN STORAGE AREAS REQUIRE GFCI | | | PROTECTION. PROVIDE CORRECTION. NEC 210.8; FBC RE | | | E3902.2 | | | 2. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE | | | EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC | | | RE R314.3, R315.1; WPB FBC 107.2.1 | | | 3. AFCI STATEMENT ON PLAN NEEDS TO BE CORRECTED. PER | | | THE 2014 NEC: "ALL BRANCH CIRCUITS THAT SUPPLY | | | 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS | | | INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, | | | LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, | | | SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, | | | LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI | | | PROTECTED." PROVIDE CORRECTION. NEC 210.12; FBC RE | | | E3902.16 | | | 4. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC EC R404.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-05-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-22 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-04-19 |
Time |
14:42 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-04-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-03-21 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2018-04-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-04-04 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-04-04 |
Time |
08:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-05-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2018-05-01 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-04-03 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2018-04-03 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2018-04-03 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
AW |
Date |
2018-04-02 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2018-03-30 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2018-04-02 13:18:31 | *************************************ZONING REVIEW | | | FAILED************************************* | | | | | | PROVIDE A SURVEY OF THE EXISTING PROPERTY. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | 561-822-1449 | | | [email protected] |
|
|
|
Account Summary | Usage Policy | Privacy Policy