Plan Review Details - Permit 18030847
| Plan Review Stops For Permit 18030847 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-04-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-04-12 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-04-12 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-03-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-03-23 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-03-23 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2018-03-23 09:55:55 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. THE REVIEW STAMP DOES NOT HAVE A COMPANY NAME ON IT. | | | IT IS NOT CLEAR WHO IS APPROVING THIS SUBMITTAL. | | | | | | 2. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS, FS471. THE PLANS WERE PRINTED REDUCED FROM A | | | DIGITAL PLAN. A DIGITAL SIGNATURE IS APPLICABLE FOR | | | DIGITAL SUBMITTALS; THIS IS A PAPER SUBMITTAL. | | | | | | 3. THE PLANS ARE REDUCED AND THEREFORE DIFFICULT TO | | | READ. FBC 107, PROVIDE FULL SIZE DRAWINGS. | | | | | | 4. THE CALCULATIONS ARE NOT IN A FORMAT ACCEPTABLE TO | | | FLORIDA BOARD OF PROFESSIONAL ENGINEERS. SEE | | | FAC61G15-23 FOR GUIDELINES FOR INDEX SHEETS. THE | | | CALCULATIONS ARE NOT SIGNED AND SEALED, LACK AN INDEX | | | PAGE, LACK A TITLE BLOCK, LACK A SIGNATURE AND SEAL. IF | | | AN INDEX SHEET IS NOT UTILIZED, EVERY PAGE SHOULD BE | | | SIGNED AND SEALED AND INCLUDE A TITLE BLOCK. | | | | | | 5. THREE SETS REQUIRED (THRESHOLD JOB), TWO SUBMITTED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-04-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-04-12 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-04-03 |
Time |
12:53 |
Sent To |
I |
|
| Notes |
| 2018-04-04 12:53:09 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-03-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-03-23 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-03-20 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2018-03-21 15:11:45 | SUBMITTAL ROUTED TO SHILL |
|
|
|
Account Summary | Usage Policy | Privacy Policy