Plan Review Details - Permit 18030798
| Plan Review Stops For Permit 18030798 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-03-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-03-28 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-03-28 |
Time |
17:35 |
Sent To |
|
|
| Notes |
| 2018-03-23 18:57:33 | RE-ROOF REVISION , BUILDING REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- ACCORDING TO THE WITHDRAWAL RESISTANCE TEST (TAS | | | 105) SUBMITTED THE CHOSEN FASTENERS ARE INSUFFICIENT. | | | NEED TO FOLLOW ENGINEER RECOMMENDATIONS. SEC. 1609.1 | | | FBC. | | | | | | 2- THE DESIGN PRESSURES FOR SELECTED SYSTEM LWC-33 IS | | | -52.5 PSF. (SEE PREVIOUS REVISION 17061315) NEED TO | | | PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR | | | PERIMETER AND CORNER AREAS AS REQUIRED BY NOTE #8 OF | | | FLORIDA PRODUCT APPROVAL SUBMITTED. NOTE: ENGINEER | | | DOING THE CALCULATIONS TO COORDINATE WITH THE TAS 105 | | | RESULTS. SEE ITEM #1 ABOVE. | | | SEC. 1609.1 FBC. | | | | | | NOTE: | | | CONTRACTOR TO PAY THE $75 PERMIT EXTENSION FEE AS | | | DISCUSSED BY MRS. YAILEN WITH SAMANTHA HILL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-03-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-03-28 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-03-23 |
Time |
18:42 |
Sent To |
I |
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |