Plan Review Details - Permit 18030737
| Plan Review Stops For Permit 18030737 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-04-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-04-05 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-04-05 |
Time |
12:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-04-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-04-20 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-04-20 |
Time |
15:55 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-04-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-04-03 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-04-03 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2018-04-03 14:17:54 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. SHEET E3.0.1 SHOWS A REVISION TO THE MAIN DISCONNECT | | | AND FEEDER TO PANELS LA/LB. ORIGINAL PLAN SHOWED THE | | | DISCONNECT ADJACENT TO THE METER WHILE THE NEW PLAN | | | SHOWS THE DISCONNECT LOCATED ON THE THIRD FLOOR. PLAN | | | DOES NOT CLEARLY SHOW IF THERE IS ANY OVERCURRENT | | | PROTECTION ON THE CONDUCTORS AT THE METER. THE SERVICE | | | DISCONNECTING MEANS SHOULD BE INSTALLED IN A LOCATION | | | THAT DOES NOT PERMIT UNPROTECTED CONDUCTORS IN THE | | | BUILDING. PROVIDE CLARIFICATION AND/OR CORRECTION. NEC | | | 230.70 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-04-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-04-09 |
Time |
13:00 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-04-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-04-16 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2018-04-17 15:11:46 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-04-09 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-03-16 |
Time |
15:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-04-02 |
Time |
17:55 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-04-02 |
Time |
16:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-06 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-06 |
Time |
11:34 |
Sent To |
|
|
| Notes |
|
|
|