Plan Review Details - Permit 18030681
| Plan Review Stops For Permit 18030681 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-03-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-03-23 |
Time |
18:33 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-03-23 |
Time |
18:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-03-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-03-19 |
Time |
19:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-03-19 |
Time |
18:49 |
Sent To |
|
|
| Notes |
| 2018-03-20 08:28:00 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017). | | | | | | 1- ACCORDING TO SEC. R301.2.1.4.3 FBC-RESIDENTIAL THIS | | | BUILDING IS LOCATED IN EXPOSURE "C" NOT "B". ACCORDING | | | TO THE WIND LOADS TABLES SUBMITTED THE PRODUCT APPROVAL | | | FL17184.9 DOESN'T MEET THE DESIGN PRESSURES FOR | | | EXPOSURE "C". PROVIDE PRODUCT APPROVAL THAT MEETS THE | | | DESIGN PRESSURES FOR EXPOSURE "C" OF WIND LOADS TABLES | | | SUBMITTED. | | | NOTE: CLARIFY WHERE ARE THESE WIND LOAD TABLES TAKEN | | | FROM. DESIGN PRESSURES MAY BE HIGHER THAN THE ONES | | | SHOWN ON THE RESIDENTIAL CODE. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | | REVIEWED DRAWINGS. DON?T STAPLE OLD DRAWINGS TO PLANS. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-03-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-03-23 |
Time |
18:33 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-03-20 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2018-03-21 14:55:34 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-03-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-03-19 |
Time |
19:01 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-03-15 |
Time |
10:25 |
Sent To |
I |
|
| Notes |
| 2018-03-16 10:25:12 | BLDG<5K |
|
|
|
Account Summary | Usage Policy | Privacy Policy