Plan Review Details - Permit 18030464
Plan Review Stops For Permit 18030464
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-04-02 Cont ID  
Sent By rmcdouga Date 2018-04-02 Time 08:43 Rev Time 0.00
Received By rmcdouga Date 2018-04-02 Time 07:58 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-03-21 Cont ID  
Sent By rmcdouga Date 2018-03-21 Time 17:42 Rev Time 0.00
Received By rmcdouga Date 2018-03-21 Time 15:40 Sent To I
Notes
2018-03-21 15:20:51PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 THERE IS A PERMIT #18020529 THAT WAS ISSUED TO REPLACE
 THE EXISTING CAST IRON SEWER PIPES WITH PVC. IT APPEARS
 THAT THIS PERMIT IS FOR REPLACING THE CONCRETE THAT WAS
 CUT AND REMOVED TO ACCESS THE BUILDING DRAIN AND SEWER.
  
 1) PROVIDE TWO SETS OF A FLOOR PLAN THAT SHOWS THE
 DIMENSIONS AND THICKNESS OF THE CONCRETE THAT IS BEING
 INSTALLED. FBC-R 606.1
  
 2) SHOW COMPLIANCE WITH FBC-R 318.1 FOR TERMITE
 PROTECTION.
  
 3) SHOW COMPLIANCE WITH FBC-R506.2.3 FOR A VAPOR
 RETARDER (6-MIL POLYETHYLENE).
  
 4) SHOW COMPLIANCE WITH FBC-R506.2.4.2 WHICH REQUIRES
 FIBER MESH CONCRETE OR WELDED WIRE REINFORCEMENT WIRE
 TO CONTROL CRACKING.
  
 5) IN ORDER TO PREVENT SETTLEMENT OF THE PATCHED AREAS,
 PROVIDE DETAILS ON DOWELING INTO THE EXISTING CONCRETE
 PER ACI 332. FBC-R506.1
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-04-02 Cont ID  
Sent By rmcdouga Date 2018-04-02 Time 08:43 Rev Time 0.00
Received By rmcdouga Date 2018-03-22 Time 11:40 Sent To  
Notes
2018-03-23 11:40:32RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-03-21 Cont ID  
Sent By rmcdouga Date 2018-03-21 Time 17:42 Rev Time 0.00
Received By rmcdouga Date 2018-03-09 Time 12:46 Sent To  
Notes
2018-03-12 12:46:37ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2018-04-02 Cont ID  
Sent By rmcdouga Date 2018-04-02 Time 07:58 Rev Time 0.00
Received By rmcdouga Date 2018-04-02 Time 07:58 Sent To  
Notes
2018-04-02 07:58:56APPROVED BY P. GRIELICH ON 3/27/18

Review Stop Z ZONING
Rev No 1 Status F Date 2018-03-14 Cont ID  
Sent By PG Date 2018-03-14 Time 14:48 Rev Time 0.00
Received By pgreilic Date 2018-03-14 Time 10:36 Sent To B
Notes
2018-03-14 14:51:231.) SHOW PROPOSED SETBACKS FOR PATIO (DISTANCE FROM
 OUTSIDE OF PATIO TO SIDE AND REAR PROPERTY LINES)
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]