| Plan Review Stops For Permit 18030448 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-04-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-04-24 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-04-24 |
Time |
14:33 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-04-06 |
Time |
18:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-04-06 |
Time |
17:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-03-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-03-14 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-03-14 |
Time |
06:58 |
Sent To |
|
|
| Notes |
| 2018-03-14 07:33:51 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 18030448 | | | ADD: 516 S. DIXIE HWY. | | | CONT: MODERN CONSTRUCTION CORP. | | | TEL: 954-422-9901 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. MARCH 14/ 2018 | | | ACTION: DENIED | | | | | | 1) THE COVERSHEET A.1 AND S1 BOTH INDICATE THEY WERE | | | CREATED USING THE 2014 FBC-B. PLEASE BE AWARE THE 2017 | | | FBC, THE 6TH EDITION OF THE FLORIDA BUILDING CODE WAS | | | ADOPTED STATEWIDE ON DEC. 31, 2017, PLEASE UPDATE THE | | | CODE REFERENCE. | | | | | | 2) THE COVERSHEET A.1 AND S1 BOTH INDICATE A NEW | | | EXTERIOR STAIR AT THE REAR OF THE STORE. THERE ARE 3 | | | RISERS LABELED 7 INCHES, 7 INCHES AND 4 INCHES A TOTAL | | | RISE OF 18 INCHES. 18/3=6 INCHES. PLEASE REVIEW SECTION | | | 1011.5.4. OF THE FBC-B. | | | FBC-B 1011.5.4 DIMENSIONAL UNIFORMITY. STAIR TREADS AND | | | RISERS SHALL BE OF UNIFORM SIZE AND SHAPE. THE | | | TOLERANCE BETWEEN THE LARGEST AND SMALLEST RISER HEIGHT | | | OR BETWEEN THE LARGEST AND SMALLEST TREAD DEPTH SHALL | | | NOT EXCEED 3/8 INCH IN ANY FLIGHT OF STAIRS. THE | | | GREATEST WINDER TREAD DEPTH AT THE WALKLINE WITHIN ANY | | | FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE | | | THAN 3/8 INCH. | | | | | | 3) SHEET S1 INDICATES THERE WAS A SOILS INVESTIGATIVE | | | REPORT FOR RECOMMENDATIONS FOR INSTALLATION, REPORT BY | | | NVS INC. REPORT # 15593 FEB. 21/ 2017. PLEASE SUBMIT | | | REPORT. FBC-B 1803.5.2 QUESTIONABLE SOIL. | | | | | | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-04-08 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-04-08 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-04-08 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-03-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-03-15 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-03-15 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2018-03-15 09:20:15 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. SHOW WINDOW CALCULATION REFERENCES THE 2011 NEC, | | | WHICH IS NOT THE CURRENT CODE. PROVIDE CORRECTION TO | | | 2014 NEC. FBC PREFACE | | | 2. PROVIDE GFCI PROTECTION FOR DRINKING FOUNTAIN. NEC | | | 422.52 | | | 3. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | | DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | | SYSTEMS, WALK IN COOLERS, SIGNS, SITE LIGHTING, AND | | | SWIMMING POOLS (WHERE APPLICABLE) ARE NOT INCLUDED IN | | | THE SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE | | | INDICATING THE REQUIRED SEPARATE PERMITS AND DATA | | | SPECIFICATION SHEET SUBMITTALS FOR ANY OF THESE SYSTEMS | | | PRESENT. FBC 105.1, 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-04-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-04-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-04-12 |
Time |
12:46 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-03-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-03-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-03-14 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2018-03-14 16:34:10 | | | | | | | | | | 1) STAIRS INDICATED AT DOOR D 102 DO NOT APPEAR TO MEET | | | THE REQUIRMENTS OF NFPA 101. | | | | | | PER NFPA 101, CHAPTER 38, NEW BUSINESS | | | | | | 38.2.2.3 STAIRS. | | | 38.2.2.3.1 STAIRS COMPLYING WITH 7.2.2 SHALL BE | | | PERMITTED | | | | | | 7.2.2 STAIRS. | | | 7.2.2.1 GENERAL. | | | 7.2.2.1.1 STAIRS USED AS A COMPONENT IN THE MEANS OF | | | EGRESS SHALL | | | CONFORM TO THE GENERAL REQUIREMENTS OF SECTION 7.1 AND | | | TO THE | | | SPECIAL REQUIREMENTS OF 7.2.2, UNLESS OTHERWISE | | | SPECIFIED IN | | | 7.2.2.1.2. | | | | | | 7.2.2.3.6* DIMENSIONAL UNIFORMITY. | | | 7.2.2.3.6.1 VARIATION IN EXCESS OF 3?16 IN. (4.8 MM) IN | | | THE SIZES OF | | | ADJACENT TREAD DEPTHS OR IN THE HEIGHT OF ADJACENT | | | RISERS SHALL BE | | | PROHIBITED, UNLESS OTHERWISE PERMITTED IN 7.2.2.3.6.3. | | | 7.2.2.3.6.2 THE VARIATION BETWEEN THE SIZES OF THE | | | LARGEST AND SMALLEST | | | RISER OR BETWEEN THE LARGEST AND SMALLEST TREAD DEPTHS | | | SHALL NOT EXCEED ? | | | IN. (9.5 MM) IN ANY FLIGHT. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-04-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-04-24 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-04-16 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2018-04-17 15:15:10 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-04-16 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-04-16 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-04-04 |
Time |
14:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-03-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-21 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-09 |
Time |
13:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-03-14 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-03-14 |
Time |
06:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-04-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-04-20 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-04-20 |
Time |
15:19 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-04-09 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-04-09 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2018-04-09 13:11:23 | 1ST REVIEW FBC-2017 MECHANICAL, EXISTING BUILDING CODE | | | PERMIT #18030448 | | | 4/9/2018 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE NEW AC CLOSET DOOR SHALL BE NON-COMBUSTIBLE PER | | | SECTION 602.2.1. | | | | | | 2) REFER TO SECTION 809.1 AND 809.2 FBC-17 EXISTING | | | BUILDING CODE AND PROVIDE MINIMUM VENTILATION | | | CALCULATIONS FOR ALL ROOMS AND SPACES PER TABLE 403.3 | | | FBC-17 MECHANICAL. PROVIDE A SCHEDULE THAT INDICATES | | | THE REQUIRED AND PROVIDED CFMS OF OUTDOOR AIR. | | | | | | 3) PLEASE PROVIDE THE SUPPLY CFMS AT EACH DIFFUSER | | | LOCATION. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-03-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-03-15 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-03-15 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2018-03-15 10:29:15 | 1ST REVIEW FBC-2014 MECHANICAL , WEST PALM BEACH | | | AMENDMENTS TO THE FBC. | | | PERMIT #18030448 | | | 3/15/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) NO MECHANICAL PLANS WERE INCLUDED WITH THE PLAN | | | SETS. PLEASE PROVIDE PLANS FOR REVIEW- SECTION 107.2.1 | | | WPB AMENDMENTS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-04-10 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-10 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-10 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-03-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-21 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-21 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2018-03-21 17:08:34 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHOW COMPLIANCE WITH FBC ACC 602 | | | | | | 2. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES | | | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET | | | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5 | | | | | | 3. SHT. P.1 UNDER PLUMB FIXTURE SCHEDULE IT LIST THE | | | MIAMI DADE CODE THAT DOES NOT APPLY TO THIS JOB,.ALL | | | PLUMBING FIXTURES AND PIPING SHALL COMPLY WITH FBC PL | | | 2017 6TH EDITION | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|