Plan Review Details - Permit 18030447
| Plan Review Stops For Permit 18030447 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-03-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-03-23 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-03-23 |
Time |
13:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-03-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-03-13 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-03-13 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2018-03-13 16:52:15 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 18030447 | | | ADD: 809 BELVEDERE RD. | | | CONT: HOMESTAR SERVICES | | | TEL: 561-201-3629 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. MARCH 13/ 2018 | | | ACTION: DENIED | | | | | | 1) SHEET A3 SHOWS A CORRIDOR WIDTH OF 4 FEET AND A | | | OUTSWING RESTROOM DOOR, THE DOOR IS NOT IDENTIFIED BY A | | | DOOR TAG. THIS SHEET IDENTIFIES DOOR TYPE A AS A 3 FOOT | | | WIDE DOOR. PLEASE SHOW COMPLIANCE WITH THE 2017 FBC-B | | | SECTION 1005.7.1 DOORS. DOORS, WHEN FULLY OPENED, SHALL | | | NOT REDUCE THE REQUIRED WIDTH BY MORE THAN 7 INCHES. | | | DOORS IN ANY POSITION SHALL NOT REDUCE THE REQUIRED | | | WIDTH BY MORE THAN ONE-HALF. | | | THE MINIMUM WIDTH OF THE CORRIDOR FINISH WALL TO WALL | | | WOULD BE 36 + 18 = 54 INCHES FOR THE OUTSWING DOOR OF | | | THE RESTROOM. | | | OR | | | 2017 FBC-ACCESSIBILITY CODE SECTION 603.2.3 DOOR SWING. | | | DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR | | | CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE | | | PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE. | | | EXCEPTIONS: | | | 2.WHERE THE TOILET ROOM OR BATHING ROOM IS FOR | | | INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING WITH | | | 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE | | | DOOR SWING, DOORS SHALL BE PERMITTED TO SWING INTO THE | | | CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY | | | FIXTURE. | | | | | | 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-03-23 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-03-23 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-03-23 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-03-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-03-15 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-03-15 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2018-03-15 08:54:51 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING CONTROLS | | | STIPULATED IN THE FBC ENERGY CODE. FBC EC C405.2 | | | 2. EMERGENCY AND EXIT LIGHTS ARE REQUIRED TO BE FED | | | FROM THE GENERAL LIGHTING CIRCUIT IN THE AREA. PROVIDE | | | CORRECTION. NEC 700.12(F) | | | 3. BREAKER FOR WATER HEATER IS STATED AS 30 AMP, WHICH | | | IS TOO LARGE FOR THIS LOAD. BREAKER SHOULD BE SIZED AT | | | 125% OF THE LOAD, WHICH WOULD REQUIRE A 25 AMP BREAKER. | | | PROVIDE CORRECTION. NEC 422.13 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-03-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-03-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-03-27 |
Time |
13:24 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-03-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-03-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-03-14 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2018-03-14 15:49:35 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) TWO EXITS ARE INDICATED ON SHEET A 3 AND E 1. THE | | | DOOR TO THE BATHROOM IS OUT SWINGING OBSTRUCTUNG THE | | | EXIT TRAVEL PATH. | | | | | | ONE EXIT MAY BE ALL THAT IS REQUIRED IF IT MEETS THE | | | REQUIRMENTS LISTED BELOW. IF SO, THE EXIT SIGN BY THE | | | BATHROOM MAY BE REMOVED AND THE BATHROOM DOOR REMAIN. | | | | | | PLEASE REVIEW ALONG WITH BUILDING COMMENTS. | | | | | | 38.2 MEANS OF EGRESS REQUIREMENTS. | | | 38.2.1 GENERAL. | | | 38.2.1.1 ALL MEANS OF EGRESS SHALL BE IN ACCORDANCE | | | WITH CHAPTER 7 AND | | | THIS CHAPTER. | | | | | | 38.2.4 NUMBER OF MEANS OF EGRESS. | | | 38.2.4.1 MEANS OF EGRESS SHALL COMPLY WITH ALL OF THE | | | FOLLOWING, EXCEPT | | | AS OTHERWISE PERMITTED BY 38.2.4.2 THROUGH 38.2.4.6: | | | (1) THE NUMBER OF MEANS OF EGRESS SHALL BE IN | | | ACCORDANCE WITH | | | SECTION 7.4. | | | (2) NOT LESS THAN TWO SEPARATE EXITS SHALL BE PROVIDED | | | ON EVERY STORY. | | | (3) NOT LESS THAN TWO SEPARATE EXITS SHALL BE | | | ACCESSIBLE FROM EVERY | | | PART OF EVERY STORY. | | | 38.2.4.2 EXIT ACCESS, AS REQUIRED BY 38.2.4.1(3), SHALL | | | BE PERMITTED TO | | | INCLUDE A SINGLE EXIT ACCESS PATH FOR THE DISTANCES | | | PERMITTED AS COMMON | | | PATHS OF TRAVEL BY 38.2.5.3. | | | 38.2.4.3 A SINGLE EXIT SHALL BE PERMITTED FOR A ROOM OR | | | AREA WITH A TOTAL | | | OCCUPANT LOAD OF LESS THAN 100 PERSONS, PROVIDED THAT | | | ALL OF THE | | | FOLLOWING CRITERIA ARE MET: | | | (1) THE EXIT SHALL DISCHARGE DIRECTLY TO THE OUTSIDE AT | | | THE LEVEL OF EXIT | | | DISCHARGE FOR THE BUILDING. | | | (2) THE TOTAL DISTANCE OF TRAVEL FROM ANY POINT, | | | INCLUDING TRAVEL WITHIN | | | THE EXIT, SHALL NOT EXCEED 100 FT (30 M). | | | (3) THE TOTAL DISTANCE OF TRAVEL SPECIFIED IN | | | 38.2.4.3(2) SHALL BE ON THE | | | SAME STORY, OR, IF TRAVERSING OF STAIRS IS NECESSARY, | | | SUCH STAIRS SHALL | | | NOT EXCEED 15 FT (4570 MM) IN HEIGHT, AND BOTH OF THE | | | FOLLOWING | | | ALSO SHALL APPLY: | | | (A) INTERIOR STAIRS SHALL BE PROVIDED WITH COMPLETE | | | ENCLOSURES TO | | | SEPARATE THEM FROM ANY OTHER PART OF THE BUILDING, WITH | | | NO | | | DOOR OPENINGS THEREIN. | | | (B) A SINGLE OUTSIDE STAIR IN ACCORDANCE WITH 7.2.2 | | | SHALL BE | | | PERMITTED TO SERVE ALL STORIES PERMITTED WITHIN THE 15 | | | FT (4570 | | | MM) VERTICAL TRAVEL LIMITATION. | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-03-27 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-03-27 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-03-21 |
Time |
13:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-03-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-15 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-09 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2018-03-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-03-13 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-03-13 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-03-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-26 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-26 |
Time |
10:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-03-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-15 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-15 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2018-03-15 12:04:13 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE WASTE ARM FOR THE SINKS SHALL BE VENTED WITH A | | | AIR ADMITTANCE VALVE OR REVENTED BACK TO THE VENT | | | STACK. IT APPEARS THAT YOU HAVE A DEVELOPED LENGTH OF | | | ABOUT 35', THE MAX YOU CAN RUN A 3" WASTE ARM FROM THE | | | VENT TO THE FIXTURE TRAP IS 12' BUSHING IT DOWN TO 2" | | | DOES NOT EXTEND THAT LENGTH YOUR DEVELOPED LENGTH WOULD | | | BE FROM THE VERTICAL STACK TO THE LAST FIXTURE TRAP. | | | FBC PL 909.1 AND TABLE 909.1 AND 901.2.1 | | | | | | 2. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES | | | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET | | | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5 | | | | | | 3. THE LAVATORY AND TOILET ARE MISSING FROM THE WATER | | | ISOMETRIC IF THEY ARE EXISTING TO REMAIN SHOW ON | | | ISOMETRIC AND MARK EXISTING THEY SHALL BE CODE | | | COMPLIANT TO CURRENT CODE. PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. PLEASE SHOW COMPLIANCE WITH FBC ACC 604.7 | | | DISPENSERS.TOILET PAPER DISPENSERS SHALL COMPLY WITH | | | 309.4 AND SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 | | | INCHES (230 MM) MAXIMUM IN FRONT OF THE WATER CLOSET | | | MEASURED TO THE CENTERLINE OF THE DISPENSER. THE OUTLET | | | OF THE DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM | | | AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR. | | | | | | 5. PLEASE SHOW COMPLIANCE WITH FBC ACC 609.4 POSITION | | | OF GRAB BARS. GRAB BARS SHALL BE INSTALLED IN A | | | HORIZONTAL POSITION, 33 INCHES (840 MM) MINIMUM AND 36 | | | INCHES (915 MM) MAXIMUM ABOVE THE FINISH FLOOR MEASURED | | | TO THE TOP OF THE GRIPPING SURFACE, | | | | | | 6. SHT. A2 UNDER TOILET FIXTURE SPECIFICATIONS #8 LIST | | | A WATER FOUNTAIN IT IS NOT SHOWN ON THE PLUMBING | | | DRAWINGS PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
|