Plan Review Details - Permit 18030438
| Plan Review Stops For Permit 18030438 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-04-02 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-04-02 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2018-04-02 10:55:36 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: . | | | | | | 1. CORRECTED | | | 2. CORRECTED | | | 3. CORRECTED | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR | | | 561-805-6742 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-03-13 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-03-13 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-03-13 |
Time |
15:56 |
Sent To |
P |
|
| Notes |
| 2018-03-13 15:56:01 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. VALUE STATED ON REVISION FORM FOR THE ADDITIONAL | | | WORK SHOWN ON PLAN APPEARS LOW. PROVIDE COPY OF SIGNED | | | CONTRACT WITH SCOPE AND VALUE OF WORK, TO INCLUDE ALL | | | MATERIALS AND LABOR. FBC 109.3 | | | 2. PROVIDE SPEC SHEET FOR TANKLESS WATER HEATER. FBC | | | 110.3 | | | 3. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. INCLUDE LOAD CALCULATION FOR PANEL IF THE | | | LOAD IS TO BE INCREASED FOR WATER HEATER. NEC 210.8, | | | 210.12, 215.5, 220, 408.4 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-04-02 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-03-29 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2018-03-30 12:41:07 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-03-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-17 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-09 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2018-03-12 13:53:27 | REVISION ROUTED TO JLEAHY |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-03-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-17 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-17 |
Time |
08:34 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |