Plan Review Details - Permit 18030288
| Plan Review Stops For Permit 18030288 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-03-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-03-26 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-03-26 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2018-03-26 13:42:29 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. DESIGNED PROFESSIONALS SIGNATURE AND SEAL SHALL BE | | | ORIGINAL. | | | | | | PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, | | | DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE | | | 61G15-23.001. | | | | | | | | 2018-03-23 10:29:41 | SEE JAKE FOR REASON TO HAVE BUILDING REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-03-23 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-03-23 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-03-23 |
Time |
10:29 |
Sent To |
B |
|
| Notes |
| 2018-03-23 10:32:46 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT | | | IS FOR THE SERVICE TO CONFIRM THE STATED AIC RATING OF | | | THE SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS | | | ADEQUATE. NEC 110.9, 110.10 | | | | | | PROVIDE NOTE THAT THE SERVICE EQUIPMENT SHALL BE MARKED | | | WITH THE MAXIMUM AVAILABLE SHORT CIRCUIT CURRENT | | | AVAILABLE PER NEC 110.24. | | | | | | PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | | | | 210.64 ELECTRICAL SERVICE AREAS AT LEAST ONE 125-VOLT, | | | SINGLE-PHASE, 15- OR 20-AMPERE-RATED RECEPTACLE OUTLET | | | SHALL BE INSTALLED WIT HIN 15 M (50 FT) OF THE | | | ELECTRICAL SERVICE EQUIPMENT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-03-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-03-26 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-03-07 |
Time |
10:52 |
Sent To |
I |
|
| Notes |
| 2018-03-08 10:53:06 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-03-15 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-03-15 |
Time |
14:04 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2018-03-08 |
Time |
16:46 |
Sent To |
E |
|
| Notes |
| 2018-03-15 14:14:19 | FAILED | | | | | | 1) PRIOR TO ZONING APPROVAL OF THIS PERMIT A MINOR | | | PLANNED DEVELOPMENT IS REQUIRED TO BE SUBMITTED TO, AND | | | APPROVED BY, THE PLANNING DIVISION. | | | | | | 2) THE PLANNING DIVISION DOES NOT APPROVE THIS LOCATION | | | FOR THE CHARGING STATIONS AND ANCILLARY FACILITIES. | | | THEY NEED TO BE LOCATED AT A LOCATION THAT IS NOT | | | FRONTING PALM BEACH LAKES BOULEVARD (OR CONGRESS | | | AVENUE). | | | | | | 3) FULL COMMENTS WILL BE GENERATED AS PART OF THE MINOR | | | PLANNED DEVELOPMENT REVIEW. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|
|