Plan Review Details - Permit 18030163
Plan Review Stops For Permit 18030163
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-03-23 Cont ID  
Sent By cthroop Date 2018-03-23 Time 16:46 Rev Time 0.00
Received By cthroop Date 2018-03-23 Time 16:07 Sent To I
Notes
2018-03-23 16:50:25INSPECTOR TO VERIFY - 1) LOCATION OF TENTS 2) LOCATION
 OF SANITARY FACILITIES 3) ACCESSIBLE RAMPS OVER CABLES
 4) ANCHORAGE DETAIL FROM INSTALLER 5) FLAME SPREAD
 REPORT PER NFTA 701 6) OCCUPANT LOAD OF TWO LARGE
 TENTS. 7) FINAL INSPECTION REQUIRED AFTER TENT REMOVAL
 AND SITE RESTORATION. VALUE INCREASED TO $25,000. CT

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-03-16 Cont ID  
Sent By cthroop Date 2018-03-16 Time 11:45 Rev Time 0.00
Received By cthroop Date 2018-03-16 Time 11:43 Sent To  
Notes
2018-03-16 12:18:50BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. CHANGES IN THE FLORIDA BUILDING CODE, SEC. 3103.1.1,
 REQUIRE MEMEBRANE STRUCTURES COMPLY WITH ADDITIONAL
 CRITERIA.
 2. PLEASE RESPOND TO EACH ITEM FROM THE THE ATTACHED
 CHECKLIST. YOU MAY UTILIZE EXISTING PERMAMENT
 STRUCTURES AND FACILITIES IN YOUR RESPONSE.
  
 MEMBRANE STRUCTURES
 PER FBC CHAPTER 31
 CHECKLIST
  
 ALL MEMBRANE STRUCTURES - PER FBC CHPT. 31
 1. DESIGN PER ASCE 55 AND SEC. 3102.1.1
 2. TYPE OF CONSTRUCTION ? TYPE IIB PER SEC. 3102.3
 3. OCCUPANCY ? ASSEMBLY PER FBC CHPT. 10
 4. BLDG. HEIGHT PER TABLE 504.3
 5. AREA PER TABLE 506.2
 6. MEANS OF EGRESS PER FBC CHPT. 10
 7. FIRE PROPAGATION PERFORMANCE PER NFPA 701 (ASTM E-84
 FLAME SPREAD)
 8. ENGINEERING DESIGN PER FBC CHPT. 16
 9. INFLATION SYSTEMS ? PRIMARY AND AUXILIARY SYSTEMS
 REQUIRED PER SEC. 3102.8
 10. BLOWER EQUIPMENT?PRIMARY AND SECONDARY POWER
 REQUIRED PER SEC. 3102.8.1.2
 NOTE: IF OCCUPANCY IS > 500 AND SG. FT. > 5,000
 STRUCTURE WILL BE CLASSIFIED AS A THRESHOLD BLDG. PER
 FS 553.71 (7)
  
 TEMPORARY MEMBRANE STRUCTURES
 (TENTS)
  
 STRUCTURES INSTALLED FOR LESS THAN 180 DAYS AND
 GREATER THAN 120 SQ. FT. WITH 10 OR MORE OCCUPANTS
  
 DEMONSTRATE COMPLIANCE WITH THE CONFORMANCE
 REQUIREMENTS OF SECTION 3103 OF THE FBC
  
 APPLICATION NEEDS TO BE SUBMITTED AT LEAST TWO (2)
 WEEKS PRIOR TO EVENT
  
 1. PROVIDE STATEMENT FOR DATE OF ASSEMBLY AND DATE OF
 REMOVAL.
 2. PROVIDE SITE PLAN. SHOW LOCATION OF PROPOSED
 STRUCTURE AND DISTANCE TO PROPERTY LINES AND OTHER
 STRUCTURES PER FBC CHPT. 6, SEC. 602.
 3. CONFORMANCE REQUIREMENTS PER SEC. 3103.1.1
 TEMPORARY STRUCTURES AND USES SHALL CONFORM TO THE
 STRUCTURAL STRENGTH, FIRE SAFETY, MEANS OF EGRESS,
 ACCESSIBILITY, LIGHT, VENTILATION AND SANITARY
 REQUIREMENTS OF THIS CODE AS NECESSARY TO ENSURE PUBLIC
 HEALTH, SAFETY AND GENERAL WELFARE.
 A. STRUCTURAL STRENGTH PER FBC CHPT. 16
 B. FIRE SAFETY ? PROVIDE FLAME SPREAD TEST REPORTS PER
 ASTM E-84 OR
 NFPA 701
 C. MEANS OF EGRESS 1) OPEN SIDES ? NO LIFE SAFETY PLAN
 REQUIRED.
  2) CLOSED SIDES ? PROVIDE LIFE SAFETY PLAN
  A) STATE OCCUPANT LOAD.
  B) IDENTIFY MEANS OF EGRESS.
  C) IDENTIFY PATH OF TRAVEL ? 100 FT. OR LESS TO
 EXIT.
  D. ACCESSIBILITY 1) IDENTIFY ACCESSIBLE ROUTES ON SITE
 PLAN
  E. LIGHT 1) OPEN SIDES ? N/A
  2) CLOSED SIDES ? PER SEC. 1008.2.1 > 1 FOOT CANDLE
  F. VENTILATION 1) OPEN SIDES ? N/A
  2) CLOSED SIDES ? PER SEC. 1203
  G. SANITARY 1) IDENTIFY EXISTING PERMANENT FACILITIES
 ON SITE PLAN
  2) PROVIDE PORTABLE FACILITIES PER TABLE 2902.1
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-03-07 Cont ID  
Sent By pleduc Date 2018-03-07 Time   Rev Time 0.00
Received By pleduc Date 2018-03-07 Time 11:11 Sent To B
Notes
2018-03-07 15:43:43THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) INDIVIDUAL TENTS OVER 900 SQ FT SHALL REQUIRE
 SEPARATE PERMITS FOR LIFE SAFETY REVIEW.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-03-16 Cont ID  
Sent By cthroop Date 2018-03-16 Time 12:25 Rev Time 0.00
Received By cthroop Date 2018-03-05 Time 13:04 Sent To I
Notes
2018-03-06 13:04:53ROUTED TO TEMP TENT