Plan Review Details - Permit 18020950
| Plan Review Stops For Permit 18020950 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-06 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-04-06 |
Time |
12:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-04-02 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-04-02 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-03-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-03-05 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-03-05 |
Time |
08:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-04-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-04-02 |
Time |
12:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-04-06 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-03-28 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2018-03-29 13:11:22 | B29 | | | | | | **TRAVELLING TOGETHER: 18020946, 18020950, 18020951** |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-03-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-13 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-22 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2018-02-28 15:36:01 | B28 | | | | | | **TRAVELLING TOGETHER: 18020946, 18020950, 18020951** |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-04-03 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-04-03 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-03-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-03-05 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-03-05 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2018-03-05 12:42:02 | 1ST REVIEW FBC-2014 MECHANICAL | | | REVISION #18020950 | | | MASTER #17060275 | | | 3/5/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) IN ORDER TO HELP EXPEDITE THE REVIEW PLEASE PROVIDE | | | A NARRATIVE FROM THE DESIGN PROFESSIONAL THAT ITEMIZES | | | AND EXPALINS WHAT CHANGES ARE VEING MADE TO THE | | | APPROVED DRAWINGS. | | | | | | 2) SHEET M1.2 : CU-2 MUST BE INSTALLED A MINIMUM OF 8' | | | ABOVE THE FINISHED FLOOR OF THE PARKING GARAGE UNLESS | | | PROTECTED FROM MOTOR VEHICLE IMPACT- SECTION 404.6. | | | | | | 3) M0.2: CHANGES HAVBE BEEN MADE TO THE AC SYSTEMS THAT | | | REQUIRE REVISED AC AND ENERGY CALCULATIONS. PLEASE | | | PROVIDE THE REVIED CALCULATIONS. | | | | | | THE MECHANICAL REVIEW IS STOPPED AT THIS TIME PENDING | | | RESUBMITTAL OF CORRECTED PLANS, REVISED CALCULATIONS, | | | AND THE REQUESTED REVISION NARRATIVE, | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-06 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-04-06 |
Time |
12:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-03-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-13 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-13 |
Time |
07:47 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy