Plan Review Details - Permit 18020921
Plan Review Stops For Permit 18020921
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-02-26 Cont ID  
Sent By jwitmer Date 2018-02-26 Time 14:04 Rev Time 0.00
Received By jwitmer Date 2018-02-26 Time 14:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2018-03-15 Cont ID  
Sent By jpearson Date 2018-03-15 Time 07:20 Rev Time 0.00
Received By jpearson Date 2018-03-15 Time 07:20 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2018-03-09 Cont ID  
Sent By jpearson Date 2018-03-09 Time 09:39 Rev Time 0.00
Received By jpearson Date 2018-03-09 Time 09:39 Sent To P
Notes
2018-03-09 09:39:13CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES.
  
 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF
 SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE,
 WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY
 SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW
 INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230,
 250.50, 250.94, 408.30 (ONLY ONE COPY OF RISER, AIC
 LETTER, AND LOAD CALCULAITON WAS PROVIDED. CODE
 REQUIRES TWO COPIES OF EACH SHEET SUBMITTED, WITH EACH
 SHEET SIGNED BY QUALIFIER OR DESIGN PROFESSIONAL. FBC
 107.1)
 2. CORRECTED.
 3. CORRECTED.
  
 NEW COMMENT:
  
 4. PROVIDE ACCURATE LOAD CALCULATION AND SIZE SERVICE
 ACCORDINGLY. LOAD CALC PROVIDED QUOTES NEC 220.32,
 WHICH DOES NOT EXIST. CALCULATION APPEARS TO USE THE
 DEMAND FACTORS FOR DWELLING UNITS, WHICH CAN NOT BE
 USED FOR THIS APPLICAITON. ALL LOADS WOULD BE FIGURED
 AT 100% PER NEC 220.42. LOAD CALCULATION MUST BE FOR
 ENTIRE SERVICE INCLUDING THE AMOUNTS FOR THE
 REFRIGERATION TRAILER, AS WELL AS A LOAD CALCULATION
 FOR THE FEEDS TO EACH TRAILER. FEEDERS MUST BE SIZED TO
 HANDLE 100% OF NON-CONTINUOUS LOAD PLUS 125% OF THE
 CONTINUOUS LOAD. IF THESE CALCULATIONS EXCEED 800 AMPS,
 THIS MUST BE DESIGNED BY ENGINEER. PROVIDE CORRECTIONS.
 NEC 215.2, 220, 230.42, 408.30; FBC 107.2.1; FS
 471.003(2)(H)
 5. RISER SHOWS # 6 AL WIRE ON A 60 AMP BREAKER TO THE
 REFRIGERATION TRAILER. THIS SIZE AL WIRE IS NOT RATED
 FOR 60 AMPS. PROVIDE CORRECTION. NEC 310.15(B)(16)
 6. ONE TRAILER IS SHOWN BEING FED FROM 2 DIFFERENT
 PANELS, PROVIDE LABEL THAT WARNS OF 2 POWER SOURCES FOR
 THIS TRAILER. NEC 230.2(E)
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-03-01 Cont ID  
Sent By jpearson Date 2018-03-01 Time 08:14 Rev Time 0.00
Received By jpearson Date 2018-03-01 Time 06:16 Sent To  
Notes
2018-03-01 08:14:14CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF
 SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE,
 WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY
 SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW
 INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230,
 250.50, 250.94, 408.30
 2. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL.
 NEC 110.3, 110.9
 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE.
 NEC 110.9, 110.10
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-02-27 Cont ID  
Sent By pleduc Date 2018-02-27 Time   Rev Time 0.00
Received By pleduc Date 2018-02-27 Time 13:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2018-03-15 Time   Rev Time 0.00
Received By lmarchan Date 2018-03-12 Time 15:16 Sent To  
Notes
2018-03-13 15:16:19RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-03-09 Cont ID  
Sent By thunt Date 2018-03-09 Time 14:46 Rev Time 0.00
Received By thunt Date 2018-03-06 Time 10:26 Sent To I
Notes
2018-03-07 10:27:06RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-03-03 Cont ID  
Sent By lcrespo Date 2018-03-03 Time 09:50 Rev Time 0.00
Received By lcrespo Date 2018-02-22 Time 10:53 Sent To  
Notes
2018-02-23 10:53:15B30

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2018-02-28 Cont ID  
Sent By ccole Date 2018-02-28 Time 16:54 Rev Time 0.00
Received By ccole Date 2018-02-28 Time 16:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-03-14 Cont ID  
Sent By lcrespo Date 2018-03-14 Time 15:53 Rev Time 0.00
Received By lcrespo Date 2018-03-14 Time 15:53 Sent To  
Notes
2018-03-14 15:54:2703/14/18 APPROVED BY PLUMBING AND SENT ELECTRICAL JP,
 LAC

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-03-09 Cont ID  
Sent By thunt Date 2018-03-09 Time 14:16 Rev Time 0.00
Received By thunt Date 2018-03-09 Time 14:16 Sent To  
Notes
2018-03-09 14:37:30PLUMBING 2ND REVIEW**DENIED**
  
  
 I HAVE READ AND UNDERSTAND YOUR RESPONCE LETTER THAT
 YOUR PLUMBING SUB WILL BE APPLYING FOR THE SUB PERMIT
 BUT SINCE YOU HAVE INCLUDED A WATER ISOMETRIC AND
 FAILED TO ADRESSS THE DISPOSAL OR HOW THE DISPOSAL IS
 TO BE HANDLED A PLUMBING REVIEW WILL BE DONE AT THIS
 TIME AND DENIED.
  
  
 1) THE MAIN BACKFLOW IS FOR THE PROTECTION OF THE
 CITY'S WATER SUPPLY. ANY BRANCH SUPPLY CONNECTION WOULD
 REQUIRED A SEPERATE ISOLATION BACKFLOW PER FBC-P 608.1.
 A SEPERATE PERMIT AND APPLICATION IS REQUIRED AND CAN
 BE DONE BY YOUR PLUMBING SUB AT A LATER DATE
  
 2) ALL DOCUMENTS PROVIDED ARE REQUIRED TO HAVE A MIN OF
 2 COPIES FBC 107.1*NEEDED TO APPROVE THIS PERMIT*
  
 ITEM NOT ADDRESSED FROM LAST REVIEW
  
 1) PLEASE PROVIDE THE SIZING OF THE HOLDING TANKS.
 EXPLAIN THE DISPOSAL PROCESS OF WHO, HOW, AND WHEN IT
 WILL BE DISPOSED OF. (COPY OF PUMP OUT CONTRACT)*
 NEEDED TO APPROVE THIS PERMIT**
  
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-03-03 Cont ID  
Sent By lcrespo Date 2018-03-03 Time 09:50 Rev Time 0.00
Received By lcrespo Date 2018-03-03 Time 09:50 Sent To  
Notes
2018-03-03 11:32:18DENIED
  
 1. PLEASE PROVIDE US WITH HOW THIS SANITARY DRAINAGE IS
 GOING TO BE DISPOSED OF, IS IT A HOLDING TANK, HOW BIG
 IT IS, HOW IT WILL BE PUMPED AND HOW MANY TIMES, THE
 LOCATION AND OR IF ITS A CITY CONNECTION WHERE WOULD BE
 IN REFERENCE TO ITS LOCATION. FS 64E-6.005 LOCATION AND
 INSTALLATION AND FS 64 E-6.0101 STATIONARY HOLDING
 TANKS.
  
 2. WHERE IS THE LOCATION OF THE WATER SOURCE? WHEN
 HOOKING TO THE WATER SERVICE A BACKFLOW PREVENTION
 DEVICE WILL BE REQUIRED. 602.2 POTABLE WATER REQUIRED.
 608.13 BACKFLOW PROTECTION. MEANS OF PROTECTION AGAINST
 BACKFLOW SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS
 608.13.1 THROUGH 608.13.10.
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 [email protected]
 561-805-6720
  

Review Stop Z ZONING
Rev No 1 Status P Date   Cont ID  
Sent By PG Date 2018-02-28 Time   Rev Time 0.00
Received By pgreilic Date 2018-02-28 Time 15:44 Sent To  
Notes
2018-02-28 16:38:21PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]