| 2018-03-13 10:32:15 | 1ST REVIEW: FBC 2017 5TH EDITION |
| | 1ST REVIEW FBC 2017 EXISTING BUILDING |
| | |
| | FAILED. |
| | |
| | 1) PLEASE PROVIDE CLEAR PLANS REGARDING THE ALTERATION |
| | TO ELECTRICAL AND BATHROOM KITCHEN REMODELING. IS THERE |
| | TO BE A SHOWER PAN REPLACEMENT? CONTRACT INDICATES SO. |
| | IF SO PROVIDE DETAIL. WIL THE KITCHEN CABINETS BE |
| | ALTERED OR IS THE ARRANGEMENT TO BE THE SAME? DRAWINGS |
| | ARE TO BE SIGNED BY THE PERSON RESPONSIBLE. THE |
| | ELECTRICIAN, PLUMBER, AND OR BUILDING CONTRACTOR MY |
| | DEVELOP DESIGN DOCUMENTS, BUT SUCH PERSON MUST INDICATE |
| | LICENSE NUMBER IF APPLICABLE, PRINT NAME, AND SIGN THE |
| | DESIGN. |
| | |
| | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN |
| | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE |
| | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE |
| | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT |
| | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| | DETERMINED BY THE BUILDING OFFICIAL. |
| | |
| | 2) THE PLUMBING PLAN REVIEW REQUESTS DEMONSTRATION OF |
| | COMPLIANCE WITH FAIR HOUSING. PLEASE BE ADVISED OF THE |
| | APPLICABILITY WHICH YOU MAY DETERMINE AT THE WEB |
| | ADDRESS BELOW. |
| | |
| | HTTPS://CODES.ICCSAFE.ORG/PUBLIC/DOCUMENT/FAC2017/FAIR- |
| | HOUSING-ACCESSIBILITY-GUIDELINES-DESIGN-GUIDELINES-FOR- |
| | ACCESSIBLE-ADAPTABLE-DWELLINGS |
| | |
| | 3) FLOORING - THE SOUND INSULATION PRODUCT DATA SHEET |
| | PROVIDED IS INSUFFICIENT AS A SUBMITTAL TO DEMONSTRATE |
| | COMPLIANCE WITH: |
| | FBC 603.1 FLAME SPREAD; INSULATION BETWEEN A FINISHED |
| | FLOOR AND SOLID DECKING W/O AN INTERVENING SPACE |
| | W/FLAME SPREAD INDEX OF 200 OR LESS. |
| | FBC 1207.2 AIR-BORNE SOUND. |
| | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| | E 90. |
| | 1207.3 STRUCTURE-BORNE SOUND. |
| | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| | |
| | THIS PRODUCT IS FOR USE WITH WOOD FLOORS, NOT TILE. |
| | PROVIDE TEST REPORTS FROM A THIRD PARTY TESTING AGENCY |
| | FOR A SOUND INSULATION PRODUCT TO DEMONSTRATE |
| | COMPLIANCE WITH THE ABOVE CRITERIA. IT MUST BE |
| | CONSISTENT WITH THE PROPOSED INSTALLATION AND THE |
| | ASSEMBLY OF THE FLOOR CEILING ASSEMBLY IN PLACE AT THE |
| | BUILDING. THIS IS A 6" OR 8" FLOOR CEILING SLAB WITH NO |
| | SUSPENDED CEILING BELOW. YOU MAY VERIFY VIA PUBLIC |
| | RECORDS REQUEST OR PERHAPS THE BUILDING MANAGEMENT CAN |
| | PROVIDE THE DATA TO YOU. |
| | |
| | |