Plan Review Details - Permit 18020788
Plan Review Stops For Permit 18020788
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-02-27 Cont ID  
Sent By cthroop Date 2018-02-27 Time 09:57 Rev Time 0.00
Received By cthroop Date 2018-02-27 Time 09:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-02-23 Cont ID  
Sent By cthroop Date 2018-02-23 Time 08:08 Rev Time 0.00
Received By cthroop Date 2018-02-23 Time 07:58 Sent To  
Notes
2018-02-23 08:45:28BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2010 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2010 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE PLAN SHOWING LOCATION OF WINDOWS WITH ROUGH
 OPENINGS. IF NO CHANGES ARE TO BE MADE TO THE ROUGH
 OPENINGS, PROVIDE STATEMENT THAT WINDOWS WILL BE LIKE
 FOR LIKE.
 2. PROVIDE DESIGN WIND LOADS FOR EACH OPENING PER FBCR
 CHPT. 3.
 3. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS OR
 SHOW LOCATION OF STRUCTURAL COLUMNS FOR MULTIPLE WINDOW
 LOCATIONS.
 4. PRODUCT APPROVAL FL 10257-R4 IS BASED ON THE 2014
 FBC AND IS OUT OF DATE. PROVIDE PRODUCT APPROVAL BASED
 ON THE CURRENT 2017 FBC.
 5. DESIGNER TO SELECT MODEL OF WINDOW TO BE INSTALLED
 FOR EACH OPENING FROM LIST OF AVAILABLE MODELS IN
 PRODUCT APPROVAL.
 6. PROVIDE INSTALLATION INSTRUCTIONS FOR EACH MODEL OF
 WINDOW SELECTED.
 7. DESIGNER TO PRINT NAME AND SIGN PLAN.
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
  
 R301.2.1 WIND DESIGN CRITERIA.
 BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN
 ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING
 THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED
 FROM FIGURE R301.2(4). THE STRUCTURAL PROVISIONS OF
 THIS CODE FOR WIND LOADS ARE NOT PERMITTED WHERE WIND
 DESIGN IS REQUIRED AS SPECIFIED IN SECTION R301.2.1.1.
 WHERE DIFFERENT CONSTRUCTION METHODS AND STRUCTURAL
 MATERIALS ARE USED FOR VARIOUS PORTIONS OF A BUILDING,
 THE APPLICABLE REQUIREMENTS OF THIS SECTION FOR EACH
 PORTION SHALL APPLY. WHERE NOT OTHERWISE SPECIFIED, THE
 WIND LOADS LISTED IN TABLE R301.2(2) ADJUSTED FOR
 HEIGHT AND EXPOSURE USING TABLE R301.2(3) SHALL BE USED
 TO DETERMINE DESIGN LOAD PERFORMANCE REQUIREMENTS FOR
 WALL COVERINGS, CURTAIN WALLS, ROOF COVERINGS, EXTERIOR
 WINDOWS, SKYLIGHTS AND EXTERIOR DOORS (OTHER THAN
 GARAGE DOORS).
  
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, WINDOW AND WINDOW MULLION SUBMITTALS.
  
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5) AND F.S. 481.229.
  
  
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2018-02-27 Cont ID  
Sent By fmittner Date 2018-02-27 Time 09:33 Rev Time 0.00
Received By fmittner Date 2018-02-27 Time 09:33 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2018-02-21 Cont ID  
Sent By fmittner Date 2018-02-21 Time 14:03 Rev Time 0.00
Received By fmittner Date 2018-02-21 Time 14:03 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-02-27 Cont ID  
Sent By cthroop Date 2018-02-27 Time 09:57 Rev Time 0.00
Received By cthroop Date 2018-02-23 Time 09:33 Sent To  
Notes
2018-02-26 09:33:15RESUB ROUTED TO FMITTNER VIA HISTORIC INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-02-23 Cont ID  
Sent By cthroop Date 2018-02-23 Time 08:45 Rev Time 0.00
Received By cthroop Date 2018-02-20 Time 10:07 Sent To I
Notes
2018-02-22 18:41:312/22 TO CT DESK
  
2018-02-21 10:07:25ROUTED TO HISTORIC VIA ZONING INBOX