Plan Review Details - Permit 18020667
Plan Review Stops For Permit 18020667
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-06-04 Cont ID  
Sent By cthroop Date 2018-06-04 Time 14:44 Rev Time 0.00
Received By cthroop Date 2018-06-04 Time 14:43 Sent To  
Notes
2018-06-04 14:44:49BUILDING ENVELOPE TO REMAIN PROTECTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-03-28 Cont ID  
Sent By cthroop Date 2018-03-28 Time 13:22 Rev Time 0.00
Received By cthroop Date 2018-03-28 Time 13:14 Sent To  
Notes
2018-03-28 13:27:26BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. CONTRACT BETWEEN HERMAN BROTHERS ENTERPRISES, INC.
 (CONTRACTOR) AND TODD SANDERS (OWNER) SPECIFIES IMPACT
 RATED WINDOWS TO BE INSTALLED.
 2. PROVIDE ACKNOWLEMENT FROM OWNER THAT NON-IMPACT
 RATED WINDOWS WILL BE INSTALLED WITH OPENING PROTECTION
 (SHUTTERS).
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-03-06 Cont ID  
Sent By cthroop Date 2018-03-06 Time 13:53 Rev Time 0.00
Received By cthroop Date 2018-03-06 Time 12:59 Sent To  
Notes
2018-03-06 14:03:15BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2010 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROPOSED WINDOWS AND SGC ARE NOT IMPACT RATED.
 2. PROVIDE SCHEDULE FOR OPENING PROTECTION.
 3. PROVIDE NOA FOR OPENING PROTECTION DEVICES.
 4. PROVIDE NOA FOR PROPOSED WALL PANELS.
 5. NOA FOR PROPOSED SGD IS NOT ON WINDOW AND DOOR
 SCHEDULE.
 6. PROVIDE LANDING AT EXTERIOR DOOR.
  
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS.
  
 R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS.
 THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH
 EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NOT BE
 LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A
 MINIMUM DIMENSION OF 36 INCHES (914 MM) MEASURED IN THE
 DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE
 PERMITTED TO HAVE A SLOPE NOT TO EXCEED 1/4 UNIT
 VERTICAL IN 12 UNITS HORIZONTAL (2-PERCENT).
  
 R311.3.1 FLOOR ELEVATIONS AT THE REQUIRED EGRESS DOORS.
 LANDINGS OR FINISHED FLOORS AT THE REQUIRED EGRESS DOOR
 SHALL NOT BE MORE THAN 11/2 INCHES (38 MM) LOWER THAN
 THE TOP OF THE THRESHOLD. EXCEPTION: THE LANDING OR
 FLOOR ON THE EXTERIOR SIDE SHALL NOT BE MORE THAN 73/4
 INCHES (196 MM) BELOW THE TOP OF THE THRESHOLD.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2018-06-05 Cont ID  
Sent By jleahy Date 2018-06-05 Time 09:16 Rev Time 0.00
Received By jleahy Date 2018-06-05 Time 09:16 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2018-03-26 Cont ID  
Sent By jleahy Date 2018-03-26 Time 16:55 Rev Time 0.00
Received By jleahy Date 2018-03-26 Time 16:46 Sent To B
Notes
2018-03-26 16:55:36FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
  
  
 RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT
 MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY WALL
 SPACE IS MORE THAN 6 FEET FROM A RECEPTACLE OUTLET.
 PROVIDE CORRECTION. NEC 210.52; FBC RE3901.2.1
  
 E3903.2 HABITABLE ROOMS. AT LEAST ONE WALL
 SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED IN
 EVERY HABITABLE ROOM AND BATHROOM. [210.70(A)(1)]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-03-01 Cont ID  
Sent By jleahy Date 2018-03-01 Time 17:07 Rev Time 0.00
Received By jleahy Date 2018-03-01 Time 17:07 Sent To B
Notes
2018-03-01 17:08:15NO ELECTRIC SHOWN

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-03-28 Cont ID  
Sent By cthroop Date 2018-03-28 Time 13:27 Rev Time 0.00
Received By cthroop Date 2018-03-13 Time 13:21 Sent To I
Notes
2018-03-14 13:21:56RESUB ROUTED TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-03-06 Cont ID  
Sent By cthroop Date 2018-03-06 Time 14:03 Rev Time 0.00
Received By cthroop Date 2018-02-15 Time 13:34 Sent To I
Notes
2018-02-16 13:34:40ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2018-03-14 Time   Rev Time 0.00
Received By pgreilic Date 2018-03-14 Time 16:18 Sent To E
Notes
2018-03-14 16:18:29PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By PG Date 2018-02-27 Time   Rev Time 0.00
Received By pgreilic Date 2018-02-26 Time 16:00 Sent To E
Notes
2018-02-27 14:27:191.) PROVIDE SITE PLAN OR INDICATE ON SURVEY WHERE
 SUNROOM WILL BE CONSTRUCTED. IS IT AN ADDITION OR BUILT
 UNDER THE EXISTING ROOFLINE? PLEASE INDICATE CLEARLY ON
 SITE PLAN OR SURVEY
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]