| Plan Review Stops For Permit 18020667 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-06-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-04 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-04 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2018-06-04 14:44:49 | BUILDING ENVELOPE TO REMAIN PROTECTED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-03-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-03-28 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-03-28 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2018-03-28 13:27:26 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. CONTRACT BETWEEN HERMAN BROTHERS ENTERPRISES, INC. | | | (CONTRACTOR) AND TODD SANDERS (OWNER) SPECIFIES IMPACT | | | RATED WINDOWS TO BE INSTALLED. | | | 2. PROVIDE ACKNOWLEMENT FROM OWNER THAT NON-IMPACT | | | RATED WINDOWS WILL BE INSTALLED WITH OPENING PROTECTION | | | (SHUTTERS). | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-03-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-03-06 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-03-06 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2018-03-06 14:03:15 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROPOSED WINDOWS AND SGC ARE NOT IMPACT RATED. | | | 2. PROVIDE SCHEDULE FOR OPENING PROTECTION. | | | 3. PROVIDE NOA FOR OPENING PROTECTION DEVICES. | | | 4. PROVIDE NOA FOR PROPOSED WALL PANELS. | | | 5. NOA FOR PROPOSED SGD IS NOT ON WINDOW AND DOOR | | | SCHEDULE. | | | 6. PROVIDE LANDING AT EXTERIOR DOOR. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS. | | | THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH | | | EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NOT BE | | | LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A | | | MINIMUM DIMENSION OF 36 INCHES (914 MM) MEASURED IN THE | | | DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE | | | PERMITTED TO HAVE A SLOPE NOT TO EXCEED 1/4 UNIT | | | VERTICAL IN 12 UNITS HORIZONTAL (2-PERCENT). | | | | | | R311.3.1 FLOOR ELEVATIONS AT THE REQUIRED EGRESS DOORS. | | | LANDINGS OR FINISHED FLOORS AT THE REQUIRED EGRESS DOOR | | | SHALL NOT BE MORE THAN 11/2 INCHES (38 MM) LOWER THAN | | | THE TOP OF THE THRESHOLD. EXCEPTION: THE LANDING OR | | | FLOOR ON THE EXTERIOR SIDE SHALL NOT BE MORE THAN 73/4 | | | INCHES (196 MM) BELOW THE TOP OF THE THRESHOLD. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-06-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-06-05 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-06-05 |
Time |
09:16 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-03-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-03-26 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-03-26 |
Time |
16:46 |
Sent To |
B |
|
| Notes |
| 2018-03-26 16:55:36 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | | | | RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT | | | MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY WALL | | | SPACE IS MORE THAN 6 FEET FROM A RECEPTACLE OUTLET. | | | PROVIDE CORRECTION. NEC 210.52; FBC RE3901.2.1 | | | | | | E3903.2 HABITABLE ROOMS. AT LEAST ONE WALL | | | SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED IN | | | EVERY HABITABLE ROOM AND BATHROOM. [210.70(A)(1)] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-03-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-03-01 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-03-01 |
Time |
17:07 |
Sent To |
B |
|
| Notes |
| 2018-03-01 17:08:15 | NO ELECTRIC SHOWN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-03-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-03-28 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-03-13 |
Time |
13:21 |
Sent To |
I |
|
| Notes |
| 2018-03-14 13:21:56 | RESUB ROUTED TO ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-03-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-03-06 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-02-15 |
Time |
13:34 |
Sent To |
I |
|
| Notes |
| 2018-02-16 13:34:40 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-03-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-03-14 |
Time |
16:18 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
PG |
Date |
2018-02-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-02-26 |
Time |
16:00 |
Sent To |
E |
|
| Notes |
| 2018-02-27 14:27:19 | 1.) PROVIDE SITE PLAN OR INDICATE ON SURVEY WHERE | | | SUNROOM WILL BE CONSTRUCTED. IS IT AN ADDITION OR BUILT | | | UNDER THE EXISTING ROOFLINE? PLEASE INDICATE CLEARLY ON | | | SITE PLAN OR SURVEY | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] |
|
|