 |
Plan Review Details - Permit 18020559
| Plan Review Stops For Permit 18020559 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-09-27 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-27 |
Time |
08:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2018-09-12 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-09-12 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-12 |
Time |
12:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2018-07-20 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-07-20 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-07-20 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2018-07-20 09:11:41 | 7/23/18 CONTRACTOR WILL ADDRESS PLUMBING AND SUBMIT NEW | | | SHEETS INCLUDING A-4 THAT WAS MISSING FORM THE SECOND | | | SET OF PLANS. | | | MECHANICAL SHEET WAS INSERTED AND IT WILL GET | | | RE-STAMPED. | | | | | | THIS WILL BE APPROVED, BUT WHEN I WAS STAMPING THE | | | SECOND SET I NOTICED SHEET A-4 AND M-1 WERE MISSING | | | FROM THE SET. | | | I CHECKED VOIDS AND THEY ARE NOT IN THERE. | | | DB CALLED CONTRACTOR AT 9:00 AM 7/20/18 AND HE WILL BE | | | BRINGING THEM IN. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2018-06-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-06-14 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-06-13 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2018-06-13 18:10:17 | PLAN | | | REVIEW COMMENTS | | | | | | 4TH REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1A) THE RESPONSE LETTER FROM THE ARCHITECT (DESIGNER OF | | | RECORD) ONLY ADDRESSES THE ADDITION TO THE EXISTING | | | SINGLE FAMILY DWELLING AND THE SITE PLAN ON SHEET A-1 | | | HAS A NOTE THAT STATES THAT THE WORK AREA FOR THIS | | | PERMIT IS THE MASTER BEDROOM AND OPEN PORCH ADDITION. | | | HOWEVER, THE PLANS STILL HAVE THE STORAGE BUILDING | | | SHOWN ON THEM. PLEASE CLARIFY. FBC 107.2.1 IF THE | | | STORAGE BUILDING IS NOT PART OF THIS PERMIT, ALL | | | DRAWINGS AND NOTES THAT PERTAIN TO IT NEED TO BE | | | REMOVED FROM THE PLANS OR CROSSED OUT BY THE DESIGNER | | | OF RECORD. | | | | | | 1) (PARTIAL COMPLIANCE. ASCE 7-16-2018 IS SPECIFIED ON | | | THE PLANS. THE 2016 EDITION OF ASCE 7 HAS NOT BEEN | | | ADOPTED INTO THE 2017 FLORIDA BUILDING CODE (SIXTH | | | EDITION). ASCE 7 - 10 IS THE EDITION THAT IS REFERENCED | | | IN THE 2017 FBC. FBC-R CHAPTER 46 REFERENCED STANDARDS. | | | PLEASE REVISE PLANS ACCORDINGLY.) FBC 107.3.5.3 - | | | PROVIDE WIND DESIGN CRITERIA. (THE COMPONENT AND | | | CLADDING PRESSURES FOR THE ROOF AND WALLS ON SHEET A-2 | | | ARE NOT CORRECT.) SPECIFY THE COMPONENT AND CLADDING | | | DESIGN PRESSURES PURSUANT TO FBC-R301.2.1 ( THE ROOF | | | SHEATHING FASTENERS ARE SPECIFIED AS RSRS 01. NAILS. | | | CLARIFY.) SPECIFY THE ROOF SHEATHING FASTENING PER | | | FBC-R803.2.3.1 (COMPLIED.) SPECIFY THE CODE EDITION AND | | | THE LEVEL OF ALTERATION FOR THE ADDITION ON THE PLANS.) | | | | | | 2) FBC ENERGY CONSERVATION - SECT. R103.1.1.2 CODE | | | COMPLIANCE CERTIFICATION. THE BUILDING'S OWNER, THE | | | OWNER'S ARCHITECT, OR OTHER AUTHORIZED AGENT LEGALLY | | | DESIGNATED BY THE OWNER SHALL CERTIFY THAT THE BUILDING | | | IS IN COMPLIANCE WITH THE CODE, AS PER SECTION 553.907, | | | FLORIDA STATUTES, PRIOR TO RECEIVING THE PERMIT TO | | | BEGIN CONSTRUCTION OR RENOVATION. FBC ENERGY | | | CONSERVATION SECTIONS R101.5.1.1.1 OR R101.5.1.1.2. | | | SUBMIT TWO SETS OF ENERGY COMPLIANCE FORMS AS REQUIRED. | | | (ONE SET IS REQUIRED FOR THE ADDITION TO THE EXISTING | | | DWELLING AND ANOTHER SET IS REQUIRED FOR THE NEW | | | STORAGE BUILDING.) | | | | | | 3) COMPLIED. | | | | | | 4) COMPLIED. NO HEATING OR COOLING WAS SPECIFIED FOR | | | THE NEW STORAGE STRUCTURE, WHICH SHALL NOT BE USED AS | | | HABITABLE SPACE. | | | | | | 5) COMPLIED. | | | | | | 6) COMPLIED. | | | | | | 7) ( SPECIFY THE SIZE AND SPACING OF THE VERTICAL | | | REINFORCING FOR THE PARAPET.) PROVIDE STRUCTURAL | | | CONSTRUCTION DETAILS FOR THE PARAPETS ON THE PLANS. | | | FBC-R301.1 | | | | | | 8) PROVIDE STRUCTURAL CONSTRUCTION DETAILS FOR THE | | | BEAMS AT THE PROPOSED COVERED PORCH ON THE PLANS. | | | FBC-R301.1 | | | | | | 9) (SPECIFY THE FASTENER TYPE, SPACING AND EMBED DEPTH | | | OF THE FASTENERS THAT WILL ATTACH THE LEDGERS.) PROVIDE | | | STRUCTURAL DETAILS FOR THE WALL LEDGERS FOR THE ROOF | | | RAFTERS AT THE PROPOSED PORCH AND MASTER BEDROOM | | | ADDITION. FBC-R301.1 | | | | | | 10) COMPLIED. | | | | | | 11) PROVIDE WINDOW AND DOOR BUCK DETAILS ON THE PLANS. | | | FBC-R609.7.2.1 | | | | | | 12) (THE ROOF SCUPPERS ARE REQUIRED TO BE LEVEL WITH | | | THE ROOF SURFACE. FBC 1503.4.2 ONLY THE OVERFLOW | | | SCUPPERS ARE SHOWN AT 4" ABOVE THE ROOF SURFACE ON THE | | | PLANS. NO CALCULATIONS ARE PROVIDED.) SPECIFY THE SIZES | | | OF THE ROOF SCUPPERS ON THE PLANS AND PROVIDE ROOF | | | SCUPPER SIZING CALCULATIONS. FBC-R903.4 & FBC 107.2.1.3 | | | | | | 13) SPECIFY THE SIZE AND LOCATION OF THE OVERFLOW | | | SCUPPERS ON THE PLANS. FBC-R903.4 | | | | | | 14) SHOW COMPLIANCE WITH FBC-R318.5 FOR SCUPPER | | | COLLECTORS AND DOWNSPOUTS THAT DISCHARGE AT LEAST ONE | | | FOOT FROM THE STRUCTURE WALLS. | | | | | | 15) COMPLIED. | | | | | | 16) COMPLIED. | | | | | | 17) COMPLIED. | | | | | | 18) COMPLIED. | | | | | | 19) COMPLIED. | | | | | | 20) COMPLIED. | | | | | | 21) COMPLIED. | | | | | | 22) COMPLIED. | | | | | | 23) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. NOTE: DUE TO THE | | | INFORMATION THAT IS MISSING FROM THE CONSTRUCTION | | | DOCUMENTS ADDITIONAL COMMENTS MAY RESULT. | | | | | | 24) NEW COMMENT. THE ROOF SLOPE IS SPECIFIED AS 1/8" ON | | | THE PLANS. FBC - R905.11.1 REQUIRES A MINIMUM SLOPE OF | | | 1/4" PER FOOT FOR A BUILT UP ROOF ON NEW CONSTRUCTION. | | | | | | 25) NEW COMMENT. AN 8X8 COLUMN WITH ONE #5 VERTICAL BAR | | | IS SHOWN ON SHEET A-2 AT THE COVERED PORCH. CLARIFY. | | | FBC-R301.1 | | | | | | 26) NEW COMMENT. THE COLUMN PAD NOTE ON SHEET A-2 | | | APPEARS TO HAVE A TYPO. IS THIS MEET TO BE #4S AT 6" | | | O.C. E.W. (EACH WAY) RATHER THAN E.A. | | | | | | 27) NEW COMMENT. ON OF THE DOWN SPOUTS FOR THE ROOF | | | SCUPPERS IS SHOWN ON SHEET A-3 AT THE OPEN AREA OF THE | | | COVER PORCH. FBC 107.2.1 | | | | | | 28) NEW COMMENT. SEE R STOP FOR ROOFING MATERIALS | | | COMMENTS. | | | | | | 29) FLORIDA STATUTE 553.80(2)(B) STATES THAT IF A LOCAL | | | GOVERNMENT FINDS IT NECESSARY, IN ORDER TO ENFORCE | | | COMPLIANCE WITH THE FLORIDA BUILDING CODE AND ISSUE A | | | PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY THE CODE | | | THREE OR MORE TIMES FOR FAILURE TO CORRECT A CODE | | | VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH | | | REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE | | | PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION A | | | FEE OF FOUR TIMES THE AMOUNT OF THE PORTION OF THE FEE | | | ATTRIBUTED TO PLAN REVIEW. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-04-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-20 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-20 |
Time |
17:29 |
Sent To |
|
|
| Notes |
| 2018-04-20 17:48:12 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | DENIED BY BUILDING - ONE SET OF PLANS HAVE A DATE OF | | | 2/1/18, THE OTHER SET HAS A DATE OF 4/4/18, APPEAR THE | | | SAME, COMMENTS NOT ADDRESSED (SAME PLANS SUBMITTED AS | | | PREVIOUS REVIEWS) | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.3.5.3 - PROVIDE WIND DESIGN CRITERIA. | | | SPECIFY THE COMPONENT AND CLADDING DESIGN PRESSURES | | | PURSUANT TO FBC-R301.2.1 SPECIFY THE ROOF SHEATHING | | | FASTENING PER FBC-R803.2.3.1 (SPECIFY THE CODE EDITION | | | AND THE LEVEL OF ALTERATION FOR THE ADDITION ON THE | | | PLANS.) | | | | | | 2ND REVIEW - WIND DESIGN CRITERIA SHOULD INCLUDE | | | EXPOSURE CLASSIFICATION (MINIMUM EXPOSURE C). | | | | | | 2-6) OK | | | | | | 7) PROVIDE STRUCTURAL CONSTRUCTION DETAILS FOR THE | | | PARAPETS ON THE PLANS. FBC-R301.1 | | | | | | 8) PROVIDE STRUCTURAL CONSTRUCTION DETAILS FOR THE | | | BEAMS AT THE PROPOSED COVERED PORCH ON THE PLANS. | | | FBC-R301.1 | | | | | | 9) PROVIDE STRUCTURAL DETAILS FOR THE WALL LEDGERS FOR | | | THE ROOF RAFTERS AT THE PROPOSED PORCH AND MASTER | | | BEDROOM ADDITION. FBC-R301.1 | | | | | | 10) SPECIFY THE STRUCTURAL CONNECTORS THAT WILL BE USED | | | TO ANCHOR THE ROOF RAFTERS FOR THE ADDITION AND THE NEW | | | CABANA BUILDING. PROVIDE A ROOF CONNECTOR SCHEDULE ON | | | THE PLANS. FBC-R301.1 | | | | | | 11) PROVIDE WINDOW AND DOOR BUCK DETAILS ON THE PLANS. | | | FBC-R609.7.2.1 | | | | | | 12) SPECIFY THE SIZES OF THE ROOF SCUPPERS ON THE PLANS | | | AND PROVIDE ROOF SCUPPER SIZING CALCULATIONS. | | | FBC-R903.4 & FBC 107.2.1.3 | | | | | | 13) SPECIFY THE SIZE AND LOCATION OF THE OVERFLOW | | | SCUPPERS ON THE PLANS. FBC-R903.4 | | | | | | 14) SHOW COMPLIANCE WITH FBC-R318.5 FOR SCUPPER | | | COLLECTORS AND DOWNSPOUTS THAT DISCHAGE AT LEAST ONE | | | FOOT FROM THE STRUCTURE WALLS. | | | | | | 15) SHOW THE DOOR AND WINDOW LINTELS AND PROVIDE A | | | LINTEL SCHEDULE ON THE PLANS. PROVIDE A DROP BEAM | | | DETAIL FOR THE POURED TIE BEAM IF THIS METHOD IS USED | | | RATHER THAN LINTELS. FBC-R606.10 | | | | | | 16) COMPLIED. | | | | | | 17) COMPLIED. | | | | | | 18) COMPLIED. | | | | | | 19) COMPLIED. | | | | | | 20) COMPLIED. | | | | | | 21) SPECIFY THE SIZE AND LOCATIONS OF THE WATER HEATERS | | | FOR BOTH THE MAIN HOUSE AND THE STORAGE BUILDING ON THE | | | PLANS. FBC-R306.4 | | | | | | 22) IN ORDER TO VERIFY THE VALUATION OF THIS PROJECT, | | | PROVIDE A COPY OF THE SIGNED CONTRACT. FBC 109.3 | | | BUILDING PERMIT VALUATION. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC, | | | PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE | | | WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. THE | | | CONTRACT THAT WAS SUBMITTED INCLUDES A POOL AND SPA | | | THAT REQUIRES A SEPARATE PERMIT. PROVIDE THE VALUE OF | | | THE POOL AND SPA, SO THAT IT CAN BE DEDUCTED FROM THE | | | CONTRACT VALUE. | | | | | | 23) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. NOTE: DUE TO THE | | | INFORMATION THAT IS MISSING FROM THE CONSTRUCTION | | | DOCUMENTS ADDITIONAL COMMENTS MAY RESULT. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-04-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-04-04 |
Time |
18:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-04-04 |
Time |
17:26 |
Sent To |
|
|
| Notes |
| 2018-04-04 18:34:41 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.3.5.3 - PROVIDE WIND DESIGN CRITERIA. | | | SPECIFY THE COMPONENT AND CLADDING DESIGN PRESSURES | | | PURSUANT TO FBC-R301.2.1 SPECIFY THE ROOF SHEATHING | | | FASTENING PER FBC-R803.2.3.1 (SPECIFY THE CODE EDITION | | | AND THE LEVEL OF ALTERATION FOR THE ADDITION ON THE | | | PLANS.) | | | | | | 2) FBC ENERGY CONSERVATION - SECT. R103.1.1.2 CODE | | | COMPLIANCE CERTIFICATION. THE BUILDING'S OWNER, THE | | | OWNER'S ARCHITECT, OR OTHER AUTHORIZED AGENT LEGALLY | | | DESIGNATED BY THE OWNER SHALL CERTIFY THAT THE BUILDING | | | IS IN COMPLIANCE WITH THE CODE, AS PER SECTION 553.907, | | | FLORIDA STATUTES, PRIOR TO RECEIVING THE PERMIT TO | | | BEGIN CONSTRUCTION OR RENOVATION. FBC ENERGY | | | CONSERVATION SECTIONS R101.5.1.1.1 OR R101.5.1.1.2. | | | SUBMIT TWO SETS OF ENERGY COMPLIANCE FORMS AS REQUIRED. | | | (ONE SET IS REQUIRED FOR THE ADDITION TO THE EXISTING | | | DWELLING AND ANOTHER SET IS REQUIRED FOR THE NEW | | | STORAGE BUILDING.) | | | | | | 3) COMPLIED. | | | | | | 4) COMPLIED. NO HEATING OR COOLING WAS SPECIFIED FOR | | | THE NEW STORAGE STRUCTURE, WHICH SHALL NOT BE USED AS | | | HABITABLE SPACE. | | | | | | 5) COMPLIED. | | | | | | 6) COMPLIED. | | | | | | 7) PROVIDE STRUCTURAL CONSTRUCTION DETAILS FOR THE | | | PARAPETS ON THE PLANS. FBC-R301.1 | | | | | | 8) PROVIDE STRUCTURAL CONSTRUCTION DETAILS FOR THE | | | BEAMS AT THE PROPOSED COVERED PORCH ON THE PLANS. | | | FBC-R301.1 | | | | | | 9) PROVIDE STRUCTURAL DETAILS FOR THE WALL LEDGERS FOR | | | THE ROOF RAFTERS AT THE PROPOSED PORCH AND MASTER | | | BEDROOM ADDITION. FBC-R301.1 | | | | | | 10) SPECIFY THE STRUCTURAL CONNECTORS THAT WILL BE USED | | | TO ANCHOR THE ROOF RAFTERS FOR THE ADDITION AND THE NEW | | | CABANA BUILDING. PROVIDE A ROOF CONNECTOR SCHEDULE ON | | | THE PLANS. FBC-R301.1 | | | | | | 11) PROVIDE WINDOW AND DOOR BUCK DETAILS ON THE PLANS. | | | FBC-R609.7.2.1 | | | | | | 12) SPECIFY THE SIZES OF THE ROOF SCUPPERS ON THE PLANS | | | AND PROVIDE ROOF SCUPPER SIZING CALCULATIONS. | | | FBC-R903.4 & FBC 107.2.1.3 | | | | | | 13) SPECIFY THE SIZE AND LOCATION OF THE OVERFLOW | | | SCUPPERS ON THE PLANS. FBC-R903.4 | | | | | | 14) SHOW COMPLIANCE WITH FBC-R318.5 FOR SCUPPER | | | COLLECTORS AND DOWNSPOUTS THAT DISCHAGE AT LEAST ONE | | | FOOT FROM THE STRUCTURE WALLS. | | | | | | 15) SHOW THE DOOR AND WINDOW LINTELS AND PROVIDE A | | | LINTEL SCHEDULE ON THE PLANS. PROVIDE A DROP BEAM | | | DETAIL FOR THE POURED TIE BEAM IF THIS METHOD IS USED | | | RATHER THAN LINTELS. FBC-R606.10 | | | | | | 16) COMPLIED. | | | | | | 17) COMPLIED. | | | | | | 18) COMPLIED. | | | | | | 19) COMPLIED. | | | | | | 20) COMPLIED. | | | | | | 21) SPECIFY THE SIZE AND LOCATIONS OF THE WATER HEATERS | | | FOR BOTH THE MAIN HOUSE AND THE STORAGE BUILDING ON THE | | | PLANS. FBC-R306.4 | | | | | | 22) IN ORDER TO VERIFY THE VALUATION OF THIS PROJECT, | | | PROVIDE A COPY OF THE SIGNED CONTRACT. FBC 109.3 | | | BUILDING PERMIT VALUATION. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC, | | | PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE | | | WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. THE | | | CONTRACT THAT WAS SUBMITTED INCLUDES A POOL AND SPA | | | THAT REQUIRES A SEPARATE PERMIT. PROVIDE THE VALUE OF | | | THE POOL AND SPA, SO THAT IT CAN BE DEDUCTED FROM THE | | | CONTRACT VALUE. | | | | | | 23) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. NOTE: DUE TO THE | | | INFORMATION THAT IS MISSING FROM THE CONSTRUCTION | | | DOCUMENTS ADDITIONAL COMMENTS MAY RESULT. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-03-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-03-20 |
Time |
19:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-03-19 |
Time |
18:45 |
Sent To |
I |
|
| Notes |
| 2018-03-20 15:23:03 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.3.5.3 - PROVIDE WIND DESIGN CRITERIA. | | | SPECIFY THE COMPONENT AND CLADDING DESIGN PRESSURES | | | PURSUANT TO FBC-R301.2.1 SPECIFY THE ROOF SHEATHING | | | FASTENING PER FBC-R803.2.3.1 | | | | | | 2) FBC ENERGY CONSERVATION - SECT. R103.1.1.2 CODE | | | COMPLIANCE CERTIFICATION. THE BUILDING'S OWNER, THE | | | OWNER'S ARCHITECT, OR OTHER AUTHORIZED AGENT LEGALLY | | | DESIGNATED BY THE OWNER SHALL CERTIFY THAT THE BUILDING | | | IS IN COMPLIANCE WITH THE CODE, AS PER SECTION 553.907, | | | FLORIDA STATUTES, PRIOR TO RECEIVING THE PERMIT TO | | | BEGIN CONSTRUCTION OR RENOVATION. FBC ENERGY | | | CONSERVATION SECTIONS R101.5.1.1.1 OR R101.5.1.1.2. | | | SUBMIT TWO SETS OF ENERGY COMPLIANCE FORMS AS REQUIRED. | | | | | | 3) SHOW THAT THE ADDITION IS IN COMPLIANCE WITH | | | FBC-R303.9 REQUIRED HEATING. WHEN THE WINTER DESIGN | | | TEMPERATURE IN TABLE R301.2(1) IS BELOW 60 DEGREES F , | | | EVERY DWELLING UNIT SHALL BE PROVIDED WITH HEATING | | | FACILITIES CAPABLE OF MAINTAINING A MINIMUM ROOM | | | TEMPERATURE OF 68 DEGREES F AT A POINT 3 FEET (914 MM) | | | ABOVE THE FLOOR AND 2 FEET (610 MM) FROM EXTERIOR WALLS | | | IN ALL HABITABLE ROOMS AT THE DESIGN TEMPERATURE. THE | | | INSTALLATION OF ONE OR MORE PORTABLE SPACE HEATERS | | | SHALL NOT BE USED TO ACHIEVE COMPLIANCE WITH THIS | | | SECTION. | | | | | | 4) FBC - 107.3.5.3 PROVIDE TWO SETS OF A MECHANICAL | | | PLAN TO SHOW EQUIPMENT AND LOCATION AND DUCT SYSTEMS | | | PER FBC-R M16 & BATH EXHAUST PER FBC-R M15. | | | | | | 5) FBC-R - M1401.3 SIZING. HEATING AND COOLING | | | EQUIPMENT SHALL BE SIZED BASED ON BUILDING LOADS | | | CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR OTHER | | | APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES. | | | PROVIDE EQUIPMENT SIZING CALCULATIONS. | | | | | | 6) THE CABANA APPEARS TO HAVE A BEDROOM WITH A CEILING | | | FAN AND A CLOSET, HOWEVER, IT IS MARKED AS STORAGE ON | | | THE PLANS. PLEASE CLARIFY. IF THIS IS TO BE USED AS | | | STORAGE THEN IT CAN NOT BE USED AS HABITABLE SPACE. IT | | | WILL NEED TO BE SPECIFIED AS A STORAGE BUILDING RATHER | | | THAN A CABANA ON THE PLANS AND THE PERMIT APPLICATION | | | THIS AREA WILL NEED TO BE "BOLDLY" LABELED NOT TO BE | | | USED AS HABITABLE SPACE ON THE PLANS. IF IT IS | | | DETERMINED THAT THE STORAGE BUILDING IS BEING USED FOR | | | OTHER THAN STORAGE IN THE FUTURE, YOU MAY BE SUBJECT TO | | | BEING FINED AND WILL BE REQUIRED TO OBTAIN A BUILDING | | | PERMIT IN ORDER TO HAVE A CHANGE OF USE FROM STORAGE TO | | | HABITABLE SPACE. NEW PLANS AND AN IMPACT FEE REVIEW | | | WILL BE REQUIRED. FBC105.1 | | | | | | 7) PROVIDE STRUCTURAL CONSTRUCTION DETAILS FOR THE | | | PARAPETS ON THE PLANS. FBC-R301.1 | | | | | | 8) PROVIDE STRUCTURAL CONSTRUCTION DETAILS FOR THE | | | BEAMS AT THE PROPOSED COVERED PORCH ON THE PLANS. | | | FBC-R301.1 | | | | | | 9) PROVIDE STRUCTURAL DETAILS FOR THE WALL LEDGERS FOR | | | THE ROOF RAFTERS AT THE PROPOSED PORCH AND MASTER | | | BEDROOM ADDITION. FBC-R301.1 | | | | | | 10) SPECIFY THE STRUCTURAL CONNECTORS THAT WILL BE USED | | | TO ANCHOR THE ROOF RAFTERS FOR THE ADDITION AND THE NEW | | | CABANA BUILDING. PROVIDE A ROOF CONNECTOR SCHEDULE ON | | | THE PLANS. FBC-R301.1 | | | | | | 11) PROVIDE WINDOW AND DOOR BUCK DETAILS ON THE PLANS. | | | FBC-R609.7.2.1 | | | | | | 12) SPECIFY THE SIZES OF THE ROOF SCUPPERS ON THE PLANS | | | AND PROVIDE ROOF SCUPPER SIZING CALCULATIONS. | | | FBC-R903.4 & FBC 107.2.1.3 | | | | | | 13) SPECIFY THE SIZE AND LOCATION OF THE OVERFLOW | | | SCUPPERS ON THE PLANS. FBC-R903.4 | | | | | | 14) SHOW COMPLIANCE WITH FBC-R318.5 FOR SCUPPER | | | COLLECTORS AND DOWNSPOUTS THAT DISCHAGE AT LEAST ONE | | | FOOT FROM THE STRUCTURE WALLS. | | | | | | 15) SHOW THE DOOR AND WINDOW LINTELS AND PROVIDE A | | | LINTEL SCHEDULE ON THE PLANS. PROVIDE A DROP BEAM | | | DETAIL FOR THE POURED TIE BEAM IF THIS METHOD IS USED | | | RATHER THAN LINTELS. FBC-R606.10 | | | | | | 16) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR THE ROOFING MATERIALS, | | | WINDOW TYPES AND EXTERIOR DOOR TYPES. | | | | | | 17) THE DOOR SCHEDULE ON THE PLAN SPECIFIES FRENCH | | | DOORS. THE DOORS ON THE FLOOR PLANS ARE DRAWN AS | | | SLIDING GLASS DOORS AND PRODUCT APPROVALS WERE | | | SUBMITTED FOR VINYL SLIDING GLASS DOORS. CLARIFY WHICH | | | DOORS ARE BEING INSTALLED AND CORRECT THE PLANS | | | ACCORDINGLY. FBC 107.2.1 | | | | | | 18) CLARIFY IF THE FRENCH DOORS #1 AND #2 IN THE | | | SCHEDULE ARE A PAIR OF 3'-0" X 6'-8" AND IF SO INDICATE | | | ON THE PLANS. ALSO, SHOW WHETHER THE DOORS ARE | | | OUT-SWING OR IN-SWING ON THE PLANS. FBC 107.2.1 | | | | | | 19) PRODUCT APPROVALS WERE SUBMITTED FOR BOTH ALUMINUM | | | AND PVC SINGLE HUNG WINDOWS. THE WINDOW SCHEDULE | | | SPECIFIES ALUMINUM WINDOWS. CLARIFY. FBC 107.2.1 | | | | | | 20) THE PRODUCT APPROVAL DRAWINGS FOR THE ALUMINUM | | | SINGLE HUNG WINDOWS THAT WERE SUBMITTED WERE NOT SHRUNK | | | TO FIT ON 8-1/2" X 11" PAPER AND THEREFORE ARE MISSING | | | INFORMATION. SUBMIT TWO SETS OF DRAWINGS THAT ARE | | | COMPLETE. FBC 107.2.1.3 | | | | | | 21) SPECIFY THE SIZE AND LOCATIONS OF THE WATER HEATERS | | | FOR BOTH THE MAIN HOUSE AND THE STORAGE BUILDING ON THE | | | PLANS. FBC-R306.4 | | | | | | 22) IN ORDER TO VERIFY THE VALUATION OF THIS PROJECT, | | | PROVIDE A COPY OF THE SIGNED CONTRACT. FBC 109.3 | | | BUILDING PERMIT VALUATION. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC, | | | PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE | | | WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | 23) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. NOTE: DUE TO THE | | | INFORMATION THAT IS MISSING FROM THE CONSTRUCTION | | | DOCUMENTS ADDITIONAL COMMENTS MAY RESULT. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-09-27 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-09-27 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-08-28 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-08-28 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2018-08-28 11:12:21 | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; FBC 107.2.1 (NOT PROVIDED ON SHEET A-2 AS | | | MENTIONED IN RESPONSE.) | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC RE | | | E3706.2, E3902 (NOT PROVIDED ON SHEET A-2 AS MENTIONED | | | IN RESPONSE.) | | | 3. CORRECTED. | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. CORRECTED. | | | 7. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | (NOT PROVIDED ON SHEET A-2 AS MENTIONED IN RESPONSE.) | | | 8. CORRECTED. | | | 9. CORRECTED. | | | 10. CORRECTED. | | | 11. PROVIDE FULL FLOOR PLAN SHOWING SMOKE ALARMS IN | | | EACH LOCATION REQUIRED PER CODE. SHOW ON PLAN ALL | | | EXISTING ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, | | | SHOW AS NEW INSTALLATIONS. SMOKE ALARMS MUST BE | | | INSTALLED AT LEAST 3 FEET FROM BATHROOM DOOR, 3 FEET | | | FROM CEILING FANS, AND 3 FEET FROM ANY MECHANICAL DUCT. | | | PROVIDE CORRECTIONS. FBC RE R314.3(4), NFPA | | | 72:29.8.3.4; FBC R314.3, FBC 107.2.1 (NOT PROVIDED AS | | | MENTIONED IN RESPONSE.) | | | 12. CORRECTED. | | | 13. CORRECTED. | | | 14. CORRECTED. | | | 15. FEE ADDED. | | | PLEASE BE ADVISED THAT THIS COMMENT HAS NOT BEEN | | | ADDRESSED FOR TWO REVIEWS. IF UPON THE THIRD REVIEW, IF | | | IT IS NECESSARY TO REJECT THE SUBMITTED PLAN A THIRD | | | TIME FOR THE SAME REASONS, AN ADDITIONAL PLAN REVIEW IS | | | REQUIRED. FLORIDA STATUTES STATE: ?WITH RESPECT TO | | | EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A | | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B)? | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2018-07-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-20 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-20 |
Time |
09:55 |
Sent To |
P |
|
| Notes |
| 2018-07-20 10:14:25 | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; FBC 107.2.1 (NOT PROVIDED ON SHEET A-2 AS | | | MENTIONED IN RESPONSE.) | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC RE | | | E3706.2, E3902 (NOT PROVIDED ON SHEET A-2 AS MENTIONED | | | IN RESPONSE.) | | | 3. CORRECTED. | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. CORRECTED. | | | 7. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | (NOT PROVIDED ON SHEET A-2 AS MENTIONED IN RESPONSE.) | | | 8. CORRECTED. | | | 9. CORRECTED. | | | 10. CORRECTED. | | | 11. PROVIDE FULL FLOOR PLAN SHOWING SMOKE ALARMS IN | | | EACH LOCATION REQUIRED PER CODE. SHOW ON PLAN ALL | | | EXISTING ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, | | | SHOW AS NEW INSTALLATIONS. SMOKE ALARMS MUST BE | | | INSTALLED AT LEAST 3 FEET FROM BATHROOM DOOR, 3 FEET | | | FROM CEILING FANS, AND 3 FEET FROM ANY MECHANICAL DUCT. | | | PROVIDE CORRECTIONS. FBC RE R314.3(4), NFPA | | | 72:29.8.3.4; FBC R314.3, FBC 107.2.1 (NOT PROVIDED AS | | | MENTIONED IN RESPONSE.) | | | 12. CORRECTED. | | | 13. CORRECTED. | | | 14. CORRECTED. | | | 15. FEE ADDED. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2018-05-17 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-05-17 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-05-17 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2018-05-17 12:57:16 | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; FBC 107.2.1 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC RE | | | E3706.2, E3902 | | | 3. PROVIDE AFCI PROTECTION PER CODE: ?BRANCH CIRCUITS | | | THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE | | | OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, DINING | | | ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, | | | BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED.? PROVIDE CORRECTION. NEC | | | 210.12; FBC RE E3902.16 | | | 4. N/A | | | 5. LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE | | | SUITABLE FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC | | | 410.10(D); FBC RE E4003.11 | | | 6. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC EC R404.1 | | | 7. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 8. N/A | | | 9. PROVIDE BLOCK NOTE THAT POOL WILL BE UNDER SEPARATE | | | PERMIT. FBC 107.2.1, 105.1 | | | 10. N/A | | | 11. PROVIDE FULL FLOOR PLAN SHOWING SMOKE ALARMS IN | | | EACH LOCATION REQUIRED PER CODE. SHOW ON PLAN ALL | | | EXISTING ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, | | | SHOW AS NEW INSTALLATIONS. SMOKE ALARMS MUST BE | | | INSTALLED AT LEAST 3 FEET FROM BATHROOM DOOR, 3 FEET | | | FROM CEILING FANS, AND 3 FEET FROM ANY MECHANICAL DUCT. | | | PROVIDE CORRECTIONS. FBC RE R314.3(4), NFPA | | | 72:29.8.3.4; FBC R314.3, FBC 107.2.1 | | | 12. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 13. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH | | | CIRCUITS SHALL HAVE NO OTHER OUTLETS. PROVIDE PER CODE. | | | NEC 210.11(C)(3) , FBC RE E3703.4 | | | 14. PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C | | | EQUIPMENT PER CODE. NEC 210.63; FBC RE E3901.12 | | | 15.PLEASE BE ADVISED THAT THESE COMMENTS HAVE NOT BEEN | | | ADDRESSED FOR THREE REVIEWS. IF UPON THE NEXT REVIEW, | | | IF IT IS NECESSARY TO REJECT THE SUBMITTED PLAN A | | | FOURTH TIME FOR THE SAME REASONS, AN ADDITIONAL PLAN | | | REVIEW IS REQUIRED. FLORIDA STATUTES STATE: ?WITH | | | RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B)? | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-04-11 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-04-11 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-04-11 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2018-04-11 09:03:49 | NO CHANGE TO PLAN | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; FBC 107.2.1 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC RE | | | E3706.2, E3902 | | | 3. PROVIDE AFCI PROTECTION PER CODE: ?BRANCH CIRCUITS | | | THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE | | | OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, DINING | | | ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, | | | BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED.? PROVIDE CORRECTION. NEC | | | 210.12; FBC RE E3902.16 | | | 4. RECEPTACLES IN STORAGE AREAS REQUIRE GFCI | | | PROTECTION. PROVIDE CORRECTION. NEC 210.8; FBC RE | | | E3902.2 | | | 5. LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE | | | SUITABLE FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC | | | 410.10(D); FBC RE E4003.11 | | | 6. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC EC R404.1 | | | 7. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 8. FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED | | | GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL | | | SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED ON | | | THE EXTERIOR SIDE OF OUTDOOR ENTRANCES/EXITS WITH GRADE | | | LEVEL ACCESS. PROVIDE CORRECTION. NEC 210.70(A)(2)(B), | | | FBC RE E3903.3 | | | 9. PROVIDE BLOCK NOTE THAT POOL WILL BE UNDER SEPARATE | | | PERMIT. FBC 107.2.1, 105.1 | | | 10. A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A | | | BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | | FEEDER OR BRANCH CIRCUIT. PROVIDE DETAILS. NEC 225.30 | | | 11. PROVIDE FULL FLOOR PLAN SHOWING SMOKE ALARMS IN | | | EACH LOCATION REQUIRED PER CODE. SHOW ON PLAN ALL | | | EXISTING ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, | | | SHOW AS NEW INSTALLATIONS. SMOKE ALARMS MUST BE | | | INSTALLED AT LEAST 3 FEET FROM BATHROOM DOOR, 3 FEET | | | FROM CEILING FANS, AND 3 FEET FROM ANY MECHANICAL DUCT. | | | PROVIDE CORRECTIONS. FBC RE R314.3(4), NFPA | | | 72:29.8.3.4; FBC R314.3, FBC 107.2.1 | | | 12. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 13. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH | | | CIRCUITS SHALL HAVE NO OTHER OUTLETS. PROVIDE PER CODE. | | | NEC 210.11(C)(3) , FBC RE E3703.4 | | | 14. PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C | | | EQUIPMENT PER CODE. NEC 210.63; FBC RE E3901.12 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR | | | 561-805-6742 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-03-14 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-03-14 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-03-14 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2018-03-14 10:16:00 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; FBC 107.2.1 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC RE | | | E3706.2, E3902 | | | 3. PROVIDE AFCI PROTECTION PER CODE: ?BRANCH CIRCUITS | | | THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE | | | OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, DINING | | | ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, | | | BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED.? PROVIDE CORRECTION. NEC | | | 210.12; FBC RE E3902.16 | | | 4. RECEPTACLES IN STORAGE AREAS REQUIRE GFCI | | | PROTECTION. PROVIDE CORRECTION. NEC 210.8; FBC RE | | | E3902.2 | | | 5. LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE | | | SUITABLE FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC | | | 410.10(D); FBC RE E4003.11 | | | 6. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC EC R404.1 | | | 7. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 8. FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED | | | GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL | | | SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED ON | | | THE EXTERIOR SIDE OF OUTDOOR ENTRANCES/EXITS WITH GRADE | | | LEVEL ACCESS. PROVIDE CORRECTION. NEC 210.70(A)(2)(B), | | | FBC RE E3903.3 | | | 9. PROVIDE BLOCK NOTE THAT POOL WILL BE UNDER SEPARATE | | | PERMIT. FBC 107.2.1, 105.1 | | | 10. A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A | | | BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | | FEEDER OR BRANCH CIRCUIT. PROVIDE DETAILS. NEC 225.30 | | | 11. PROVIDE FULL FLOOR PLAN SHOWING SMOKE ALARMS IN | | | EACH LOCATION REQUIRED PER CODE. SHOW ON PLAN ALL | | | EXISTING ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, | | | SHOW AS NEW INSTALLATIONS. SMOKE ALARMS MUST BE | | | INSTALLED AT LEAST 3 FEET FROM BATHROOM DOOR, 3 FEET | | | FROM CEILING FANS, AND 3 FEET FROM ANY MECHANICAL DUCT. | | | PROVIDE CORRECTIONS. FBC RE R314.3(4), NFPA | | | 72:29.8.3.4; FBC R314.3, FBC 107.2.1 | | | 12. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 13. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH | | | CIRCUITS SHALL HAVE NO OTHER OUTLETS. PROVIDE PER CODE. | | | NEC 210.11(C)(3) , FBC RE E3703.4 | | | 14. PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C | | | EQUIPMENT PER CODE. NEC 210.63; FBC RE E3901.12 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
4 |
Status |
P |
Date |
2018-05-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-05-30 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-05-30 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
F |
Date |
2018-04-13 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2018-04-13 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2018-04-13 |
Time |
10:51 |
Sent To |
B |
|
| Notes |
| 2018-04-13 10:54:39 | 4/13/2018 - APPLICANT NEEDS TO REVISE PLANS FOR | | | CONSTRUCTION OF REAR ADDITION ONLY, WHICH WAS APPROVED | | | AT STAFF LEVEL. THE REAR CABANA IS AWAITING HPB REVIEW | | | IN MAY. DLE |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2018-04-06 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2018-04-06 |
Time |
13:36 |
Sent To |
Z |
|
| Notes |
| 2018-04-06 13:37:18 | 4/6/2018 - AWAITING LEVEL 2 HISTORIC REVIEW - COA | | | REQUIRED. APPLICANT INFORMED. DLE |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-02-28 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2018-02-28 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2018-02-28 |
Time |
08:16 |
Sent To |
Z |
|
| Notes |
| 2018-02-28 13:52:39 | 2/28/2018 - THIS IS A CONTRIBUTING PROPERTY TO THE | | | FLAMINGO PARK HISTORIC DISTRICT. ANY PROPOSED ADDITIONS | | | OR EXTERIOR ALTERATIONS SHOULD FIRST BE SUBMITTED TO | | | THE HISTORIC PRESERVATION OFFICE FOR REVIEW. ALSO, | | | VINYL PRODUCTS ARE NOT PERMITTED FOR USE WITHOUT | | | HISTORIC PRESERVATION BOARD APPROVAL. THE COA | | | APPLICATION MAY BE FOUND HERE: HTTP://WPB.ORG/DEPARTMEN | | | TS/DEVELOPMENT-SERVICES/HISTORIC-PRESERVATION/APPLICATI | | | ONS?PAGE=2 QUESTIONS MAY BE DIRECTED TO DESIREE | | | ESTABROOK, HISTORIC PRESERVATION PLANNER, AT | | | 561.822.1428 OR [email protected] | | 2018-02-28 08:16:29 | DESIREE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2018-10-01 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-10-01 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-09-14 |
Time |
12:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2018-09-12 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-09-12 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-07-30 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2018-08-06 10:10:47 | R07 | | 2018-07-31 14:24:58 | LIBRARY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-07-23 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-07-23 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-07-10 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-06-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-06-14 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-05-11 |
Time |
16:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-04-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-20 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-03-22 |
Time |
13:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-03-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-03-20 |
Time |
19:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-02-13 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2018-05-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-05-04 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-05-04 |
Time |
17:40 |
Sent To |
|
|
| Notes |
| 2018-05-04 17:42:17 | MU2018 - 14955, NO FEES WERE DUE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-03-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-03-19 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-03-19 |
Time |
18:45 |
Sent To |
|
|
| Notes |
| 2018-03-19 18:57:46 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | (ADDITION AND CABANA) | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2018-10-01 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-10-01 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-10-01 |
Time |
15:33 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-08-23 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-08-23 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-08-23 |
Time |
14:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-03-27 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-03-27 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-03-27 |
Time |
14:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-03-16 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-03-16 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-03-16 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2018-03-16 14:45:46 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 - 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE | | | PERMITTED TO BE SUBMITTED WHERE APPROVED BY THE | | | BUILDING OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2018-10-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-10-02 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-10-02 |
Time |
14:25 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2018-08-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-08-21 |
Time |
05:07 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-08-21 |
Time |
03:03 |
Sent To |
|
|
| Notes |
| 2018-08-21 04:18:36 | 1) SHT. A -1 - PLUMBING RISERS - SUBMIT TWO COPIES OF A | | | CODE COMPLIANT SANITARY RISER DIAGRAM. 2ND REQUEST. | | | NOTHING HAS BEEN DONE TO THE SANITARY RISERS TO CORRECT | | | THE DEFICIENCIES. | | | PLUMBING RISER - MASTER BATHROOM: | | | A)THE DOUBLE LAVATORIES SHALL BE STACKED AND | | | VENTED.2017 FBCR-SEC.P3101.2 P3101.2.1. | | | B) THE MASTER BATHROOM SANITARY RISER SHOWS AN EXISTING | | | SANITARY LINE FOR "BASEMENT PLUMBING" BUT THERE IS NO | | | REFERENCE TO A BASEMENT NOR IS A BASEMENT SHOWN IN | | | THESE PLANS . CLARIFY. | | | 2) SIZE ALL SECTIONS OF THE SANITARY DRAINAGE LINES AND | | | VENT LINES ON BOTH SANITARY RISER DIAGRAMS.2ND REQUEST. | | | 3) THE PLANS SHOW A MASTER BATHROOM AND AN EXISTING | | | BATHROOM BUT THE SANITARY RISER DIAGRAMS ARE FOR A | | | MASTER BATH AND ALSO A NEW STORAGE BATH. CLARIFY.THE | | | STORAGE ROOM IS SHOWN ON SHEET A-2 BUT HAS BEEN OMITTED | | | FROM OTHER SHEETS. CLARIFY. | | | 4) SHT. A-2 - ADDITION ROOF PLAN - SUBMIT ADDITIONAL | | | INFORMATION AS TO HOW THE SIZE OF THE SCUPPERS WERE | | | CALCULATED. THERE IS NO TABLE IN THE PLUMBING CODE FOR | | | SIZING SCUPPERS. THE ROOF PLAN REFERS TO TABLE 1106.3 | | | OF THE FLORIDA PLUMBING CODE FOR THE SIZING OF THE | | | SCUPPERS. THIS TABLE IS FOR SIZING VERTICAL LEADERS, | | | NOT SCUPPERS. SCUPPERS SHALL BE SIZED IN ACCORDANCE | | | WITH 2017 FBC-PLUMBING SEC.1108.3, 1101.7. NOTE: THERE | | | IS NO TABLE THAT SPECIFIES THE SQUARE FOOTAGE OF THE | | | ROOF BEING DRAINED. ALL THE TABLES ARE BASED ON THE | | | FLOW RATE.2017 FBC SEC.1101.7, 1108.1. | | | 5) THE SIZE OF THE MASTER BATH SHOWER SHALL COMPLY WITH | | | 2017 FBCR SEC.P2708.1. | | | 6) PLUMBING FIXTURES SHALL BE SPACED IN ACCORDANCE WITH | | | 2017 FBCR SEC.P2705.1. | | | | | | NOTE: I SUGGEST CONTACTING THIS PLAN REVIEWER TO | | | DISCUSS THE COMMENTS SO COMPLIANCE CAN BE ACHIEVED AND | | | THE PLUMBING CAN BE APPROVED. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2018-07-23 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-23 |
Time |
06:24 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-20 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2018-07-20 15:25:15 | 1) SHT. A -1 - PLUMBING RISERS - SUBMIT TWO COPIES OF A | | | CODE COMPLIANT SANITARY RISER DIAGRAM. THERE ARE TOO | | | MANY CODE VIOLATIONS TO LIST. WPB AMEND.TO FBC SEC. | | | 107.2.1. | | | 2) SIZE ALL SECTIONS OF THE DRAINAGE LINES AND VENT | | | LINES ON THE SANITARY RISER DIAGRAMS WHEN TEY ARE | | | REVISED. | | | 3) THE PLANS SHOW A MASTER BATHROOM AND AN EXISTING | | | BATHROOM BUT THE SANITARY RISER DIAGRAMS ARE FOR A | | | MASTER BATH AND ALSO A NEW STORAGE BATH. CLARIFY. | | | 4) SHT. A-2 - ADDITION ROOF PLAN - SUBMIT A DETAIL OF | | | THE ROOF SCUPPER. WPB AMEND. TO FBC SEC. 107.2.1. | | | 5) SHT. A-4 IS MISSING FROM ONE SET OF PLANS. | | | 6) THE ROOF PLAN REFERS TO TABLE 1106.3 OF THE FLORIDA | | | PLUMBING CODE. THIS TABLE IS FOR VERTICAL LEADER | | | SIZING, NOT SCUPPERS.CLARIFY. | | | 7) SHOW REQUIREMENTS FOR SECONDARY (EMERGENCY) ROOF | | | DRAINAGE PER 2017 FBC-PLUMBING SEC. 1108.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2018-06-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-12 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-12 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2018-06-12 17:02:40 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. WE RECEIVED A LETTER FROM MERCURIO CONSTRUCTION | | | STATING THAT THE CABANA BATHROOM AND STORAGE WAS BEING | | | REMOVED FROM THE SCOPE OF WORK FOR THIS PERMIT BUT THE | | | PLANS STILL HAVE A FLOOR PLAN, PLUMBING RISER, | | | ELECTRICAL PLAN AND ELEVATION SHOWING THE CABANA THEY | | | WILL NEED TO BE REMOVED FROM THE PLANS I CANNOT APPROVE | | | A SET OF PLANS THAT HAS WORK THAT IS NOT UNDER THE | | | SCOPE OF THE PERMIT BEING ISSUED. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-03-26 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-03-26 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-03-26 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2018-03-26 16:17:46 | 03/26/18 APPROVED BY PLUMBING AND PUT BACK IN R26, LAC |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-03-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-16 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-16 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2018-03-16 16:46:14 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE BATHROOM DIMENSIONS TO SHOW COMPLIANCE WITH | | | FBC RES | | | | | | P2708.1 GENERAL.SHOWER COMPARTMENTS SHALL HAVE NOT LESS | | | THAN 900 SQUARE INCHES (0.6 M2) OF INTERIOR | | | CROSS-SECTIONAL AREA. SHOWER COMPARTMENTS SHALL BE NOT | | | LESS THAN 30 INCHES (762 MM) IN MINIMUM DIMENSION | | | MEASURED FROM THE FINISHED INTERIOR DIMENSION OF THE | | | SHOWER COMPARTMENT, EXCLUSIVE OF FIXTURE VALVES, SHOWER | | | HEADS, SOAP DISHES, AND SAFETY GRAB BARS OR RAILS. THE | | | MINIMUM REQUIRED AREA AND DIMENSION SHALL BE MEASURED | | | FROM THE FINISHED INTERIOR DIMENSION AT A HEIGHT EQUAL | | | TO THE TOP OF THE THRESHOLD AND AT A POINT TANGENT TO | | | ITS CENTERLINE AND SHALL BE CONTINUED TO A HEIGHT OF | | | NOT LESS THAN 70 INCHES (1778 MM) ABOVE THE SHOWER | | | DRAIN OUTLET. HINGED SHOWER DOORS SHALL OPEN OUTWARD. | | | THE WALL AREA ABOVE BUILT-IN TUBS HAVING INSTALLED | | | SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE | | | CONSTRUCTED IN ACCORDANCE WITH SECTION R702.4. SUCH | | | WALLS SHALL FORM A WATER-TIGHT JOINT WITH EACH OTHER | | | AND WITH EITHER THE TUB, RECEPTOR OR SHOWER FLOOR. | | | | | | | | | P2705.1 (5) .WATER CLOSETS, LAVATORIES AND BIDETS. A | | | WATER CLOSET, LAVATORY OR BIDET SHALL NOT BE SET CLOSER | | | THAN 15 INCHES (381 MM) FROM ITS CENTER TO ANY SIDE | | | WALL, PARTITION OR VANITY OR CLOSER THAN 30 INCHES (762 | | | MM) CENTER-TO-CENTER BETWEEN ADJACENT FIXTURES. THERE | | | SHALL BE A CLEARANCE OF NOT LESS THAN 21 INCHES (533 | | | MM) IN FRONT OF A WATER CLOSET, LAVATORY OR BIDET TO | | | ANY WALL, FIXTURE OR DOOR. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2018-07-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-07-23 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-07-23 |
Time |
07:13 |
Sent To |
|
|
| Notes |
| 2018-07-23 07:14:58 | FL#2533-R19 SYSTEM NO. W-97 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-06-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-06-14 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-06-14 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2018-06-14 15:11:38 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1. A ROOF SUB PERMIT WAS SUBMITTED. INDICATE WHICH | | | ASSEMBLY IS PROPOSED AND PROVIDE ENGINEERING FOR ZONE 2 | | | AND 3 IF APPLICABLE. IF THIS INFORMATION IS NOT | | | PROVIDED, THE ROOF SUB PERMIT APPLICATION WILL BE | | | VOIDED AND A ROOF SUB PERMIT WITH ALL REQUIRED | | | INFORMATION (PRODUCT APPROVAL, ASSEMBLY PROPOSED, AND | | | ENGINEERING IF APPLICABLE) WILL BE REQUIRED PRIOR TO | | | INSTALLATION. | | | | | | 2) TWO SETS OF A ROOFING PRODUCT APPROVAL WERE | | | SUBMITTED. THE PROPOSED ASSEMBLY WAS NOT INDICATED. FBC | | | 107.2.1 | | | | | | 3) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR THE ROOFING MATERIALS. | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-04-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-20 |
Time |
17:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-20 |
Time |
17:48 |
Sent To |
|
|
| Notes |
| 2018-04-20 17:50:40 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. A ROOF SUB PERMIT WAS SUBMITTED. INDICATE WHICH | | | ASSEMBLY IS PROPOSED AND PROVIDE ENGINEERING FOR ZONE 2 | | | AND 3 IF APPLICABLE. IF THIS INFORMATION IS NOT | | | PROVIDED, THE ROOF SUB PERMIT APPLICATION WILL BE | | | VOIDED AND A ROOF SUB PERMIT WITH ALL REQUIRED | | | INFORMATION (PRODUCT APPROVAL, ASSEMBLY PROPOSED, AND | | | ENGINEERING IF APPLICABLE) WILL BE REQUIRED PRIOR TO | | | INSTALLATION. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2018-10-05 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-10-05 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-10-05 |
Time |
16:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-05-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-05-30 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-05-30 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2018-04-06 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2018-04-06 |
Time |
13:37 |
Sent To |
B |
|
| Notes |
| 2018-04-06 13:37:33 | 4/6/2018 - AWAITING LEVEL 2 HISTORIC REVIEW - COA | | | REQUIRED. APPLICANT INFORMED. DLE |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-02-28 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2018-02-28 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2018-02-28 |
Time |
13:35 |
Sent To |
B |
|
| Notes |
| 2018-02-28 13:36:59 | 2/28/2018 - PLEASE ADDRESS HISTORIC COMMENTS AND SUBMIT | | | COA FOR REVIEW. PROPOSED ADDITION AND OPEN PORCH SHOULD | | | FALL WITHIN THE CALCULATED LOT COVERAGE MAXIMUMS FOR | | | THIS LOT AND PROPERTY. QUESTIONS MAY BE DIRECTED TO | | | DESIREE ESTABROOK, HISTORIC PRESERVATION PLANNER, AT | | | 561.822.1428. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |