Plan Review Details - Permit 18020386
Plan Review Stops For Permit 18020386
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2018-03-07 Cont ID  
Sent By lcrespo Date 2018-03-07 Time 07:22 Rev Time 0.00
Received By lcrespo Date 2018-03-07 Time 07:04 Sent To  
Notes
2018-03-07 07:22:453/7/18 APPROVED BY PLUMBING AND SENT TO PROCESSING, LAC

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2018-02-15 Cont ID  
Sent By thunt Date 2018-02-15 Time 05:33 Rev Time 0.00
Received By thunt Date 2018-02-15 Time 05:33 Sent To  
Notes
2018-02-15 05:34:2902/15/2018 1ST GAS REVIEW**DENIED **
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1) TOTAL JOB COST SEEMS LOW. VALUE MUST INCLUDE COST OF
 ALL EQUIPMENT INCLUDING TANKLESS AND STOVE. PROVIDE
 BONA FIDE SIGNED CONTRACT PER WPB AMENDMENTS TO THE FBC
 109.3
  
 2) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS /
 INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY
 COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND
 FBC-2014 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2014
 FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED
 AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS
 APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF
 INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1
  
 3) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE ADDED GAS
 APPLIANCES. WHERE COMBUSTION AIR IS PROVIDED BY THE
 BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM
 SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN
 ADDITION TO THE REQUIRED VENTILATION AIR. FGC
 SEC.304.9.3 OR FBCR G2407.9.3.
  
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-03-07 Cont ID  
Sent By lcrespo Date 2018-03-07 Time 07:22 Rev Time 0.00
Received By lcrespo Date 2018-03-05 Time 11:05 Sent To  
Notes
2018-03-06 11:05:24RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-02-15 Cont ID  
Sent By thunt Date 2018-02-15 Time 05:34 Rev Time 0.00
Received By thunt Date 2018-02-08 Time 13:42 Sent To I
Notes
2018-02-09 13:42:51PLUMB <5K