| Plan Review Stops For Permit 18020385 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2018-10-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-10-31 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-10-31 |
Time |
07:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-23 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-23 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2018-10-23 14:39:32 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 18020385 | | | ADD: 400 CLEMATIS ST. | | | CONT: TBD/ TO BE DETERMINED | | | TEL: 954-574-4968 / RACHEL MYERS | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: TUES. OCT.23 | | | ACTION: DENIED | | | | | | 4X FEE / NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B) | | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | 1) THE PLAN SHEET A0.1 INDICATES THIS TO BE A LEVEL 3 | | | ALTERATION. PLEASE NOTE THIS IS A CHANGE IN OCCUPANCY | | | FROM AN A3 GYM TO A MERCANTILE. UNDER THE 2017 FBC | | | EXISTING BUILDING CODE FOR A CHANGE IN OCCUPANCY FOR A | | | PORTION OF A BUILDING YOU GO TO: | | | 2017 FBC-EXIST. SECTION 1001.2.2.1PARTIAL CHANGE OF | | | OCCUPANCY. WHERE THE OCCUPANCY CLASSIFICATION OR GROUP | | | OF A PORTION OF AN EXISTING BUILDING IS CHANGED, | | | SECTION 1012 SHALL APPLY. ALL OF 1012.1THROUGH 1012.8. | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2-6) COMPLIED. | | | | | | 7) SEE IMPACT FEE STATEMENT. BEFORE A PERMIT TO | | | CONSTRUCT, MAY BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. ONE SET OF PLANS WILL HAVE TO BE | | | TAKEN (BY THE CONTRACTOR OR REPRESENTATIVE) TO THE PALM | | | BEACH COUNTY IMPACT FEE OFFICE LOCATED AT 2300 N. JOG | | | RD. ROOMS 2W01-2W14 WEST PALM BEACH, FL. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-08-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-08-22 |
Time |
19:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-08-21 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2018-08-20 17:58:34 | CHANGE OF OCCUPANCY ((M) , SECOND BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS | | | | | | | | | ORIGINAL COMMENT: | | | 1) CODE INFORMATION SHEET A0.1: | | | CODE ANALYSIS AND PROJECT DATE INDICATES THIS IS A | | | LEVEL III ALTERATION. PLEASE NOTE THIS IS A CHANGE OF | | | OCCUPANCY SEE THE 2017 FBC-EXISTING BUILDING CODE | | | CHAPTER 10. | | | EXIST. BLDG. CODE 1001.2.2.1 PARTIAL CHANGE OF | | | OCCUPANCY. WHERE THE OCCUPANCY CLASSIFICATION OR GROUP | | | OF A PORTION OF AN EXISTING BUILDING IS CHANGED, | | | SECTION 1012 SHALL APPLY. | | | | | | RESPONSE: | | | THE CORRECT CLASSIFICATION OF WORK IS ALTERATION LEVEL | | | 3 AND CHANGE OF OCCUPANCY. SEC. 501.1 FBC-EXISTING | | | BUILDING. IT IS IMPORTANT TO CLEARLY SPECIFY SCOPE OF | | | WORK. TYPICALLY, ALTERATION LEVEL 3 PROJECTS REQUIRE A | | | CERTIFICATE OF COMPLETION, BUT WHEN THE SCOPE OF WORK | | | INVOLVES A CHANGE OF OCCUPANCY, THEN A CERTIFICATE OF | | | OCCUPANCY IS REQUIRED. | | | SINCE THIS IS A CHANGE OF OCCUPANCY A CERTIFICATE OF | | | OCCUPANCY SHALL BE USED AS REQUIRED BY SEC. 1001.3 | | | FBC-EXISTING BUILDING. | | | | | | ORIGINAL COMMENT: | | | 2) SHEET S3 THE TABLE FOR PRESSURES DOES NOT STATE IT | | | IS FOR 10 SQ. FT., THE TABLE DOES STATE THE PRESSURES | | | ARE IN VASD. THE WALL PRESSURES FOR WALL ZONE 4 ARE 4 | | | PSF LOW, WE FIGURE- 49.24 PSF AND WALL ZONE 5 THE | | | PRESSURES OF -60.76 TAKEN FOR A MEAN ROOF HEIGHT OF 35 | | | FEET. THIS BUILDING IS A MEAN ROOF HEIGHT GIVEN AT 34 | | | FEET MEAN ROOF HEIGHT. | | | | | | RESPONSE: | | | THE 10% REDUCTION OF GCP VALUES IS OK (FIGURE 30.4-1 | | | ASCE 7-10) BUT THE HEIGHT SPECIFIED ON SHEET S3 SEEMS | | | TO BE INCORRECT. IT DOESN'T MATCH HEIGHT SHOWN ON | | | SHEETS A7 AND A8. REVISE AS REQUIRED. ALSO, THE DESIGN | | | PRESSURES STILL DON'T CLARIFY THE EFFECTIVE WIND AREA. | | | ARE THE VALUES GIVEN FOR 10PSF?. PLEASE CLARIFY. | | | ACCORDING TO NOTE #4 OF FIGURE 30.4-1 EACH COMPONENT | | | SHALL BE DESIGNED FOR MAXIMUM POSITIVE AND NEGATIVE | | | PRESSURES. THIS IS REQUIRED FOR PROPER REVIEW OF | | | PRODUCT APPROVALS SUBMITTED. | | | | | | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A RESPONSE LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | NEW COMMENTS: | | | 4) FLOOR PLAN LAYOUT WAS CHANGED. PRELIMINARY | | | MERCHANDISE PLAN SHEET F-1P WAS NOT REVISED REFLECTING | | | THE PROPOSED CHANGES. PROVIDE REVISED SHEET. SEC. | | | 107.2.1 CITY AMENDMENTS. | | | | | | 5)FIRE SPRINKLER SHEET FP-2 WAS REVISED. NEED THE | | | ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY | | | SEC. 61G15-23.003 F.A.C. DIGITAL SIGNATURE IS ONLY FOR | | | DIGITAL SUBMITTALS. THIS IS NOT A DIGITAL SUBMITTAL. | | | | | | 6- INFORMATION ONLY: FLOOR PLAN NOTE #4 ON SHEET A1 | | | CALL FOR AWNING REPLACEMENT. COMPLETE DRAWINGS AND | | | SPECIFICATIONS NEED TO BE SUBMITTED UNDER A SEPARATE | | | PERMIT. | | | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | | REVIEWED DRAWINGS. DO NOT STAPLE OLD DRAWINGS TO PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-03-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-03-01 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-02-28 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2018-03-01 10:51:29 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 18020385 | | | ADD: 400 CLEMATIS ST. (FIRST FLOOR) | | | CONT: TBD/ TO BE DETERMINED | | | TEL: 954-574-4968 RACHAEL MYERS | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURS. MARCH 01/ 2018 | | | ACTION: DENIED | | | | | | 1) CODE INFORMATION SHEET A0.1: | | | | | | 1A) CODE ANALYSIS AND PROJECT DATE INDICATES THIS IS A | | | LEVEL III ALTERATION. PLEASE NOTE THIS IS A CHANGE OF | | | OCCUPANCY SEE THE 2017 FBC-EXISTING BUILDING CODE | | | CHAPTER 10. | | | EXIST. BLDG. CODE 1001.2.2.1 PARTIAL CHANGE OF | | | OCCUPANCY. WHERE THE OCCUPANCY CLASSIFICATION OR GROUP | | | OF A PORTION OF AN EXISTING BUILDING IS CHANGED, | | | SECTION 1012 SHALL APPLY. | | | | | | 1B) THE OCCUPANT LOAD GIVEN FOR THE MERCANTILE AREA IS | | | 12, 290 SQ. FT. /30 = 410 OCCUPANTS. PLEASE BE AWARE OF | | | A CHANGE IN THE 2017 FBC-B IN TABLE 1004.1.2. UNDER THE | | | HEADING FOR MERCANTILE. THE CODE NOW USES 60 SQ. FT. | | | PER OCCUPANT FOR ALL FLOORS. WHICH WILL GIVE AN | | | OCCUPANT LOAD OF 205, PLEASE CORRECT. | | | | | | 2) SHEET A0.5 THE LIFE SAFETY SHEET INDICATES UNDER THE | | | HEADING EGRESS DATA FOR MERCANTILE. TRAVEL DISTANCES | | | FOR NEW MERCANTILE (A) COMMON PATH OF TRAVEL 100 FT. | | | PLEASE REVISE THE PLAN, SEE 2017 FBC-B TABLE 1006.2.1. | | | | | | 3) SHEET A2 INDICATES THE PARAPET WALL HEIGHTS OF THE | | | BUILDING. IN THE SOUTHWEST CORNER OF THE BUILDING THE | | | SOUTH SIDE PARAPET SECTION LABELED 21 IS 28 INCHES | | | HIGH, THE WEST SIDE OF THE BUILDING LABELED 22 IS 32 | | | INCHES HIGH, JUST THE NORTHWEST CORNER 68 INCHES HIGH | | | AND IN THE NORTHWEST CORNER IDENTIFIED AS 24 IS 33 | | | INCHES HIGH. NOT UNTIL YOU GET TO THE NORTHEAST CORNER | | | OF THE BUILDING IS THE PARAPET 40 INCHES HIGH ? OF THE | | | NORTH PARAPET IS 36 INCHES OR LESS. WITH THIS BEING | | | SAID THE ROOF PRESSURES IN ROOF ZONE 3 WILL BE ZONE 3 | | | PRESSURES NOT THE ROOF ZONE 2 AS WOULD BE THE CASE WITH | | | A MINIMUM OF 3 FOOT PARAPET ALL THE WAY AROUND THE | | | BUILDING. SHEET S3 THE ROOF ZONE 3 PRESSURES ARE THE | | | SAME IN ROOF ZONES 2 AND 3. | | | | | | 4) SHEET S3 THE TABLE FOR PRESSURES DOES NOT STATE IT | | | IS FOR 10 SQ. FT., THE TABLE DOES STATE THE PRESSURES | | | ARE IN VASD. THE WALL PRESSURES FOR WALL ZONE 4 ARE 4 | | | PSF LOW, WE FIGURE- 49.24 PSF AND WALL ZONE 5 THE | | | PRESSURES OF -60.76 TAKEN FOR A MEAN ROOF HEIGHT OF 35 | | | FEET. THIS BUILDING IS A MEAN ROOF HEIGHT GIVEN AT 34 | | | FEET MEAN ROOF HEIGHT. | | | | | | 5) PROVISO: RATHER THAN REQUIRE A RESIDENT INSPECTOR | | | SINCE THE WELDED AND BOLTED CONNECTIONS IS VERY LIMITED | | | PLEASE PROVIDE COMPLIANCE WITH: | | | THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE | | | SPECIFICATIONS & WELDER OPERATOR PERFORMANCE | | | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED | | | STANDARDS AT TIME OF INSPECTION. | | | 2014 FBC-B 2204.1 WELDING | | | 2014 FBC-B 2204.2 BOLTING. | | | | | | 6) PLEASE REVIEW FIRE CHIEF LEDUC COMMENT ABOUT NOT | | | ENOUGH EXIT AND EXIT DIRECTIONAL SIGNAGE SEE SHEETS | | | A0.5 & E3 AND COMPLIANCE WITH: | | | 2017 FBC-B SECTION 1013.1 WHERE REQUIRED. EXITS AND | | | EXIT ACCESS DOORS SHALL BE MARKED BY AN APPROVED EXIT | | | SIGN READILY VISIBLE FROM ANY DIRECTION OF EGRESS | | | TRAVEL. THE PATH OF EGRESS TRAVEL TO EXITS AND WITHIN | | | EXITS SHALL BE MARKED BY READILY VISIBLE EXIT SIGNS TO | | | CLEARLY INDICATE THE DIRECTION OF EGRESS TRAVEL IN | | | CASES WHERE THE EXIT OR THE PATH OF EGRESS TRAVEL IS | | | NOT IMMEDIATELY VISIBLE TO THE OCCUPANTS. INTERVENING | | | MEANS OF EGRESS DOORS WITHIN EXITS SHALL BE MARKED BY | | | EXIT SIGNS. EXIT SIGN PLACEMENT SHALL BE SUCH THAT NO | | | POINT IN AN EXIT ACCESS CORRIDOR OR EXIT PASSAGEWAY IS | | | MORE THAN 100 FEET (30 480 MM) OR THE LISTED VIEWING | | | DISTANCE FOR THE SIGN, WHICHEVER IS LESS, FROM THE | | | NEAREST VISIBLE EXIT SIGN. | | | | | | 7) SHEET S2 SHOWS 2 DOOR CUT SECTIONS 4/S4 AND 7/S4 | | | BOTH USING A C1 TYPE COLUMN AND A HSS6X6 3/8 INCH STEEL | | | BOX BEAM, THE DETAILS DO NOT PROVIDE THE WELD | | | CONNECTION TO THE VERTICAL COLUMN C1. 107.2.1.3 | | | ADDITIONAL INFORMATION REQUIRED. | | | | | | 8) SHEET A6 DETAIL # 9 & 10 SHOWS A REFRIGERANT LINE | | | CHASE (WALL) DETAIL. PLEASE NOTE TO HAVE A CHASE AND | | | NOT A SHAFT THE FLOOR PENETRATIONS THROUGH THE FLOOR | | | WILL NEED TO PROVIDE THROUGH THE FLOOR/ CEILING | | | ASSEMBLIES IN COMPLIANCE WITH: | | | 2017 FBC-B 714.4 HORIZONTAL ASSEMBLIES | | | FBC-B 714.4.1 THROUGH PENETRATIONS. | | | FBC-B 714.4.1.1 INSTALLATION. THROUGH PENETRATIONS | | | SHALL BE INSTALLED AS TESTED IN THE APPROVED FIRE- | | | RESISTANCE-RATED ASSEMBLY. | | | 714.4.1.2 THROUGH-PENETRATION FIRESTOP SYSTEM. THROUGH | | | PENETRATIONS SHALL BE PROTECTED BY AN APPROVED | | | THROUGH-PENETRATION FIRESTOP SYSTEM INSTALLED AND | | | TESTED IN ACCORDANCE WITH ASTM E814 OR UL 1479, WITH A | | | MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF 0.01 INCH OF | | | WATER (2.49 PA). THE SYSTEM SHALL HAVE AN F RATING/T | | | RATING OF NOT LESS THAN 1 HOUR BUT NOT LESS THAN THE | | | REQUIRED RATING OF THE FLOOR PENETRATED. | | | SHEETS A23 NOR A24 SHOW A FLOOR/ CEILING THROUGH | | | PENETRATION AND FIRE STOPPING SYSTEM. | | | | | | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-09-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-28 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-28 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-08-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-09 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-09 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-03-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-03-16 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-03-16 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2018-03-16 13:34:51 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | | DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | | SYSTEMS, WALK IN COOLERS, SIGNS, SITE LIGHTING, AND | | | SWIMMING POOLS (WHERE APPLICABLE) ARE NOT INCLUDED IN | | | THE SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE | | | INDICATING THE REQUIRED SEPARATE PERMITS AND DATA | | | SPECIFICATION SHEET SUBMITTALS FOR ANY OF THESE SYSTEMS | | | PRESENT. FBC 105.1, 107.2.1 | | | 2. PROVIDE DETAILS OF THE EXISTING SERVICE LATERAL AND | | | GROUNDING ELECTRODE SYSTEM TO VERIFY SIZES ARE CORRECT | | | FOR SERVICE. FBC 107.2.1; NEC 215.2, 215.5 | | | 3. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94 | | | 4. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES | | | EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN | | | RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR | | | LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC C405.4.2 | | | 5. FIRE REVIEWER NOTED 7 LOCATIONS ON PLAN FOR EXIT | | | LIGHTS IN THE PATH OF TRAVEL, WHICH NEED TO BE ADDED TO | | | LIGHTING PLAN. PROVIDE PER FIRE COMMENTS. FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2018-08-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-09 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-09 |
Time |
17:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2018-09-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-09-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-09-18 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-07-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-07-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-07-13 |
Time |
13:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-02-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-02-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-02-13 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2018-02-13 13:36:31 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) SHEETS A 0.5 & E 3 - THERE DOES NOT APPEAR TO BE | | | SUFFICIENT EXIT SIGNS IN THE PATH OF TRAVEL. ENSURE | | | THERE IS PROPER EXIT SIGNAGE CLEARLY VISIBLE INDICATING | | | AND LEADING TO THE EXIT ALONG THE PATH OF TRAVEL. | | | | | | | | | | | | 2) SHEET E 1.1 - THERE IS INDICATION OF A FIRE ALARM | | | SYSTEM BY CVS. ENSURE THAT THE FIRE ALARM SYSTEM IS | | | TIED INTO THE EXISITNG BUILDING SYSTEM. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-10-31 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-10-31 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-10-29 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2018-10-30 14:31:15 | RESUB ROUTED TO JWITMER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-23 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-13 |
Time |
16:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-08-22 |
Time |
19:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-07-06 |
Time |
10:47 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-03-28 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-03-28 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-02-08 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
5 |
Status |
P |
Date |
2018-11-15 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-11-15 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-11-15 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2018-11-15 09:22:24 | REVIEWED BY PBC. NO FEES WERE ASSESSED. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
F |
Date |
2018-10-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-10-31 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-10-31 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2018-10-31 08:25:08 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. ONE SET OF | | | PLANS WILL HAVE TO BE TAKEN (BY THE CONTRACTOR OR | | | REPRESENTATIVE) TO THE PALM BEACH COUNTY IMPACT FEE | | | OFFICE LOCATED AT 2300 N. JOG RD. ROOMS 2W01-2W14 WEST | | | PALM BEACH, FL. THE ACTUAL PERMIT SET OF PLANS MUST BE | | | STAMPED BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL | | | (561)233-5025 FOR MORE INFORMATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-10-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2018-10-23 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-10-31 08:24:52 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. ONE SET OF | | | PLANS WILL HAVE TO BE TAKEN (BY THE CONTRACTOR OR | | | REPRESENTATIVE) TO THE PALM BEACH COUNTY IMPACT FEE | | | OFFICE LOCATED AT 2300 N. JOG RD. ROOMS 2W01-2W14 WEST | | | PALM BEACH, FL. THE ACTUAL PERMIT SET OF PLANS MUST BE | | | STAMPED BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL | | | (561)233-5025 FOR MORE INFORMATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2018-08-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-08-21 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-08-21 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2018-08-21 08:55:32 | IMPACT FEES - PAPER SUBMITTALS | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-03-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-03-01 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-02-28 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2018-03-01 09:42:08 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. ONE SET OF | | | PLANS WILL HAVE TO BE TAKEN (BY THE CONTRACTOR OR | | | REPRESENTATIVE) TO THE PALM BEACH COUNTY IMPACT FEE | | | OFFICE LOCATED AT 2300 N. JOG RD. ROOMS 2W01-2W14 WEST | | | PALM BEACH, FL. THE ACTUAL PERMIT SET OF PLANS MUST BE | | | STAMPED BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL | | | (561)233-5025 FOR MORE INFORMATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-10-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-10-05 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-10-04 |
Time |
08:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-07-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-07-31 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-07-31 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2018-07-31 12:52:31 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #18020385 | | | 7/31/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE SUBMITTED AC CALCULATIONS FROM THE EOR INDICATE | | | THAT THE HP SYSTEMS 1-5, AS SHOWN IN THE SCHEDULES ON | | | SHEET M3, ARE OVERSIZED IN COOLING AND HEATING | | | CAPACITIES- SEE SECTION C403.2.2 FBC EC. MISSING FROM | | | THE CALCULATIONS ARE THE MINI-SPLIT SYSTEMS 6, 7, & 8. | | | | | | 2) THE SUBMITTED COMCHECK ENERGY COMPLIANCE CERTIFICATE | | | SHOWS CAPACITIES FOR COOLING AND HEATING THAT DON'T | | | MATCH THE CAPACITIES IN THE SCHEDULES. PLEASE NOTE THAT | | | THE EFFICIENCY RATING OF 12.30 EER FOR SYSTEM #3 DOES | | | NOT MATCH THE SCHEDULE WHICH INDICATES 11.9 EER. | | | | | | 3) M1.1: VERIFY MIMIMUM 10' CLEARANCE EXISTS FROM THE | | | NEW O/A INTAKE LOUVER TO THE STREET- SECTION 401.4 FBC | | | M. | | | | | | 4) SHEET P1.1: THE CONDENSATE FROM AHU-7 & 8 SHALL NOT | | | DRAIN INTO THE CITY SANITARY PER SECTION 90-126 CITY OF | | | WPB CODE OF ORDINANCES. PLEASE PROVIDE AN APPROVED | | | LOCATION SUCH AS A STORM DRAIN OR PERMEABLE GROUND. | | | | | | 5) REQUIRED SUBMITTALS: NOA'S OR PRODUCT APROVALS FOR | | | THE LOUVERS AND AC STANDS, ERV, DUCT SMOKE DETECTORS, | | | C02 SENSORS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-03-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-03-12 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-03-12 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2018-03-12 16:39:30 | 1ST REVIEW FBC-2017 MECHANICAL, ENERGY CONSERVATION | | | CODES | | | PERMIT #18020385 | | | 3/12/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE COOLING AND HEATING CALCULATIONS FOR THE NEW | | | AC SYSTEMS- SECTION C403.2.1 FBC-17 ENERGY | | | CONSERVATION. | | | | | | 2) SHEET M3: THE MINIMUM O/A SCHEDULE SHOWS THE NUMBER | | | OF OCCUPANTS IN THE RETAIL AREAS TO BE NOT IN | | | COMPLIANCE WITH TABLE 403.1.1. BASED ON THE TABLE THE | | | NUMBER OF OCCUPANTS SHALL BE: (AHU-1 53 PERSONS) AHU-2 | | | (31 PERSONS), AND AHU-3 (47 PERSONS). PLEASE REVISE THE | | | CALCULATIONS AND PLANS ACCORDINGLY. | | | | | | 3) M1: DUCT SMOKE DETECTORS ARE REQUIRED IN THE SUPPLY | | | SYSTEMS OF AHU'S 1, 2, & 3- SECTION 606.2.1. | | | | | | 4) M1 & A4: PLEASE SHOW THE LOCATIONS OF THE DIFFUSERS | | | AND RETURN GRILLS IN THE REFLECTIVE CEILING PLAN. | | | | | | 5) M2: PROVIDE A GUARD ALONG THE ROOF EDGE IN THE AREA | | | OF HP 1 & 2 OR PLACE A NOTE TO INDICATE THE EXISTING | | | PARAPET IS A MINIMUM 42" HIGH ABOVE THE FINISHED ROOF | | | SURFACE- SEE SECTION 304.11 | | | | | | 6) M2: PROVIDE WIND LOAD ENGINEERING FOR INSTALLTION OF | | | THE NEW ROOFTOP STANDS AND CONDENSING UNITS- SECTION | | | 301.15. PLEASE INCLUDE THE WIND DESIGN CRITERIA IN | | | ACCORDANCE WITH SECTION1609 FBC-17 BUILDING, AND SUBMIT | | | THE MIAMI-DADE NOA FOR THE CONDENSER STANDS WITH | | | MARKUPS AND APPROVAL STAMP BY THE EOR. | | | | | | 7) M3: THE EQUIPMENT SCHEDULE FOR THE MINI-SPLIT SYSTEM | | | IS INCOMPLETE. PLEASE PROVIDE THE COOLING AND HEATING | | | CAPACITIES OF THE SYSTEM. | | | | | | 8) PROVIDE A FLORIDA PRODUCT APPROVAL AND/OR A | | | MIAMI-DADE NOA FOR THE O/A LOUVER, AND A SUBMITTAL FOR | | | THE O/A AIR MOTORIZED DAMPERS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-10-10 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-10-10 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-10-10 |
Time |
12:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-08-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-20 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-20 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2018-08-20 11:34:09 | 2ND REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHEET P1.1: THE CONDENSATE FROM AHU-7 & 8 SHALL NOT | | | DRAIN INTO THE CITY SANITARY PER SECTION 90-126 CITY OF | | | WPB CODE OF ORDINANCES. PLEASE PROVIDE AN APPROVED | | | LOCATION SUCH AS A STORM DRAIN OR PERMEABLE GROUND. | | | | | | 2. SHT. P1.1 - P2 THE SINK IN THE PHARMACY S1 SHALL | | | CONNECT TO THE BUILDING DRAIN DOWN STREAM OF THE | | | BATHROOM GROUP. PER FBC PL 912.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-03-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-20 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-20 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2018-03-20 09:43:24 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE SHOW COMPLIANCE WITH FBC ACC 604.5.1 SIDE | | | WALL. THE SIDE WALL GRAB BAR SHALL BE 42 INCHES LONG | | | MINIMUM, LOCATED 12 INCHES MAXIMUM FROM THE REAR WALL | | | AND EXTENDING 54 INCHES MINIMUM FROM THE REAR WALL. | | | | | | 2. PLEASE SHOW COMPLIANCE WITH FBC ACC 604.7 | | | DISPENSERS. TOILET PAPER DISPENSERS SHALL COMPLY WITH | | | 309.4 AND SHALL BE 7 INCHES MINIMUM AND 9 INCHES | | | MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE | | | CENTERLINE OF THE DISPENSER. | | | | | | 3.PLEASE SHOW THE CLEAR FOOR SPACE WITH DIMENSIONS , | | | FOR THE TOILET AND LAVATORY. PER FBC ACC 604.3.1, 606.2 | | | | | | 4. PLEASE SHOW COMPLIANCE WITH FBC ACC 604.2 | | | LOCATION.THE WATER CLOSET SHALL BE POSITIONED WITH A | | | WALL OR PARTITION TO THE REAR AND TO ONE SIDE. THE | | | CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES | | | MINIMUM TO 18 INCHES MAXIMUM FROM THE SIDE WALL OR | | | PARTITION. IT APPEARS THAT THE DIMENSION MAY HAVE BEEN | | | SHOWN BUT IT DID NOT LINE UP WITH THE TOILET. | | | | | | 5. SHT P4 DETAIL #7 THE WALL DRAIN BOX WHEN CONNECTED | | | TO THE STORM DRAINAGE SHALL HAVE A BACKWATER VALVE. PER | | | FBC PL 1101.9 | | | | | | 6. SHT P4 DETAIL # 2 THE REQUIRED TEMPERED WATER AT THE | | | LAVATORY IN THE BATHROOM SHALL BE DELIVERED THROUGH A | | | WATER TEMPERATURE LIMITING DEVISE THAT MEETS ASSE 1070 | | | OR CSA B125.3 THE TEMPERING VALVE SPARCO 102C LISTED ON | | | DETAIL #2 DOES NOT COMPLY. THE REQUIREMENT FOR TEMPERED | | | WATER ONLY ONLY APPLIES TO THE LAVATORY'S IN THE | | | BATHROOMS . PER FBC PL 416.5 | | | | | | 7. PLEASE SHOW THAT THE 19 GAL WATER HEATER IS LARGE | | | ENOUGH TO SUPPLY THE 5 SINKS WITH HOT OR TEMPERED WATER | | | YOU CAN REFERENCE APPENDIX E OF THE FBC PL OR | | | MANUFACTURE SIZING. PER WPB AMEND FBC AMEND TO FBC | | | 107.2.1 | | | | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-08-15 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2018-08-15 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2018-08-15 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2018-08-15 13:18:53 | PROVISO: 1. AWNING IS NOT INCLUDED INTHIS PERMIT. | | | 2. SHEET F-1P SHALL BE REPLACED TO REFLECT NEW DOOR ON | | | DIXIE HWAY AND CHANGES ON COOLERS. | | | 3. PACKAGE SALES ARE NOT PERMITTED UNTIL CODE AMENDMENT | | | IS APPROVED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-03-28 |
|
|
Cont ID |
|
| Sent By |
AA |
Date |
2018-03-28 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2018-03-28 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2018-03-28 15:16:35 | 1. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE | | | WITH ACTIVE USE REQUIREMENT ALONG DIXIE HWAY. | | | 2. PLEASE PROVIDE INFORMAITON TO CONFIRM COMPLIANCE | | | WITH TRANSPARENCY REQUIREMENT ALONG DIXIE HWAY. | | | PROPOSAL IS BLOCKING EXISTING WINDOWS ALONG THIS | | | FRONTAGE. | | | 3. ALCOHOL SALES FOR CONSUMPTION OFF OF PREMISE IS NOT | | | CURRENTLY PERMITTED. PLEASE REMOVE REFERENCE TO IT IN | | | THE SUBMITTED DRAWINGS. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. |
|
|