| Plan Review Stops For Permit 18020359 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-11-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-11-14 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2018-11-14 07:43:14 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 18020359 | | | ADD: 319 CLEMATIS ST. SUITE: 100 | | | CONT: GERALD CONTRACTING | | | TEL: 561-832-9785 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: WED. 11/14/2018 | | | ACTION: BUILDING PROVISO | | | | | | 1) THE EGRESS DOOR (PAIR OF DOORS) SHALL COMPLY WITH: | | | 2018 FBC-ACCESSIBILITY CODE SECTION 404.2.5 THRESHOLDS. | | | THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE 1/2 INCH | | | (13 MM) HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES | | | IN LEVEL AT DOORWAYS SHALL COMPLY WITH 302 AND 303. | | | | | | EXCEPTION: EXISTING OR ALTERED THRESHOLDS 3/4 INCH (19 | | | MM) HIGH MAXIMUM THAT HAVE A BEVELED EDGE ON EACH | | | SIDE WITH A SLOPE NOT STEEPER THAN 1:2 SHALL NOT BE | | | REQUIRED TO COMPLY WITH 404.2.5. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-03-28 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-03-28 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2018-03-28 09:31:01 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 18020359 | | | ADD: 319 CLEMATIS ST. SUITE: 100 | | | CONT: GERALD CONTRACTING | | | TEL: 561-832-9785 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. 28/2018 | | | ACTION: BUILDING PROVISO | | | | | | 1) THE EGRESS DOOR (PAIR OF DOORS) SHALL COMPLY WITH: | | | 2018 FBC-ACCESSIBILITY CODE SECTION 404.2.5 THRESHOLDS. | | | THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE 1/2 INCH | | | (13 MM) HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES | | | IN LEVEL AT DOORWAYS SHALL COMPLY WITH 302 AND 303. | | | | | | EXCEPTION: EXISTING OR ALTERED THRESHOLDS 3/4 INCH (19 | | | MM) HIGH MAXIMUM THAT HAVE A BEVELED EDGE ON EACH | | | SIDE WITH A SLOPE NOT STEEPER THAN 1:2 SHALL NOT BE | | | REQUIRED TO COMPLY WITH 404.2.5. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-02-16 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-02-16 |
Time |
17:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2018-11-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-11-05 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-11-05 |
Time |
17:37 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2018-05-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-05-15 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-05-15 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2018-05-15 12:11:58 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED | | | 2. CORRECTED | | | 3. CORRECTED. | | | 4. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES | | | EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN | | | RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR | | | LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC C405.4.2 | | | 5. CORRECTED. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-04-02 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-04-02 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2018-04-02 09:36:35 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. CORRECTED | | | 2. CORRECTED | | | 3. PROVIDE LOAD CALCULATION FOR EXISTING PANEL, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF PANEL IS | | | ADEQUATE. NEC 215.2, 220, 408.30 | | | 4. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES | | | EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN | | | RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR | | | LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC C405.4.2 | | | 5. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING CONTROLS | | | STIPULATED IN THE FBC ENERGY CODE. FBC EC C405.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR | | | 561-805-6742 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-02-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-02-27 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-02-27 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2018-02-27 11:26:39 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. NOTE 1 AND NOTE 17 SPECIFY THE 2011 NEC. THE NEC | | | SPECIFIED FOR DESIGN IS NOT THE CURRENT CODE. PROVIDE | | | CORRECTION. FBC PREFACE (ALSO SEE CURRENT CODES ABOVE) | | | 2. A CONFLICT EXIST BETWEEN PANEL SCHEDULE AND RISER | | | DIAGRAM. PANEL SCHEDULE SHOWS # 8 WIRE ON A 60 AMP | | | BREAKER FEEDING SUB-PANEL IN SUITE 100. RISER SHOWS (3) | | | 1/0 CONDUCTORS FEEDING THE SAME PANEL. THE # 8 WIRE IS | | | NOT RATED FOR 60 AMPS, AND THE 1/0 WIRE WOULD NOT FIT | | | ON A 60 AMP BREAKER. PROVIDE CORRECTION. NEC 110.3, | | | 215.2, 310.15 | | | 3. PROVIDE LOAD CALCULATION FOR EXISTING PANEL, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF PANEL IS | | | ADEQUATE. NEC 215.2, 220, 408.30 | | | 4. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES | | | EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN | | | RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR | | | LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC C405.4.2 | | | 5. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING CONTROLS | | | STIPULATED IN THE FBC ENERGY CODE. FBC EC C405.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-03-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-03-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-03-29 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-02-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-02-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-02-13 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-12-11 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-11-30 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2018-12-03 13:06:52 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-11-14 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-11-14 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-10-29 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2018-10-30 16:06:03 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-05-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-05-22 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-05-10 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2018-05-14 13:30:28 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-09 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-26 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-03-06 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-03-06 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-02-08 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2018-12-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-12-12 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-12-12 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2018-12-12 15:29:44 | MECHANICAL PROVISO | | | 12/12/18 | | | | | | 1) A REVISION IS REQUIRED TO PROVIDE A NEW AC SYSTEM TO | | | CONDITION THE NEW SUITE #100. | | | | | | 2) THE MAIN SUPPLY AND RETURN DUCT TRUNKS FROM THE | | | EXISTING AC SYSTEM SHALL NOT PENETRATE THE DEMISING | | | WALL OR PROVIDE CONDITIONING TO SUITE #100. | | | | | | CCOLE |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-12-11 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-12-11 |
Time |
10:43 |
Sent To |
P |
|
| Notes |
| 2018-12-11 11:17:56 | 4TH REVIEW FBC-2017 MECHANICAL | | | PERMIT #18020359 | | | 12/11/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | | | | 1) SHEET MEP-1: THE EXISTING AC #1 SYSTEM CANNOT | | | CONDITION THE AIR IN BOTH SUITES 100 AND 110. SUITES | | | 100 AND 110 ARE SEPARATE TENANT SPACES AND SEPARATE | | | ZONES AS DEFINED IN SECTION 202 FBC EC, AND THEREFORE | | | REQUIRE INDIVIDUAL AND SEPARATE THERMOSTATIC CONTROLS | | | PER SECTION C403.2.4.1 FBC EC. TYPICALY, SEPARATE AC | | | SYSTEMS MUST BE PROVIDED FOR EACH ZONE. | | | | | | 2) MEP-1: THE REVISED PLAN INDICATES A MOTORIZED | | | "JUMPER" IN THE MAIN SUPPLY DUCT WHICH APPEARS TO BE A | | | MISPRINT FOR "MOTORIZED DAMPER". PLEASE NOTE THAT O/A | | | BY MANUFACTURER'S SPECIFICATIONS MUST BE INTRODUCED | | | INTO THE RETURN AIR SYSTEMS SO THAT IT CAN BECOME | | | CONDITIONED AND DEHUMIDIFIED SUPPLY AIR. | | | | | | 3) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2018-11-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-11-07 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-11-07 |
Time |
09:08 |
Sent To |
B |
|
| Notes |
| 2018-11-07 10:03:11 | 3RD REVIEW FBC-2017 MECHANICAL | | | PERMIT #18020359 | | | 11/7/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET MEP-1: THE UPDATED PLANS SHOW A NEW TENANT | | | BUILD-OUT. REFER TO SECTION 809.2 FBC-17 EXISTING | | | BUILDING CODE AND PROVIDE MINIMUM VENTILATION | | | CALCULATIONS FOR ALL ROOMS AND SPACES PER TABLE | | | 403.3.1.1 FBC-17 MECHANICAL. PROVIDE A SCHEDULE THAT | | | INDICATES THE REQUIRED AND PROVIDED CFMS OF OUTDOOR | | | AIR. | | | | | | 2) MEP-1: THE CURRENT PLAN APPEARS TO SHOW THE AIR | | | DISTRIBUTION SYSTEM FOR THE NEW TENANT SPACE CONNECTED | | | TO A SYSTEM OUTSIDE OF THE TENANT SPACE. PLEASE CLARIFY | | | HOW THE SYSTEM IN THE NEW TENANT SPACE WILL BE | | | CONTROLLED, AND HOW ACCESS FOR SERVICE AND FOR | | | EMERGENCY SHUTDOWN OF THE SYSTEM WILL BE PROVIDED. | | | | | | IN ADDITION TO THE COMMENTS ABOVE, PLEASE ANSWER THESE | | | QUESTIONS CLEARLY ON THE PLAN AND ALSO IN A RESPONSE | | | NARRATIVE FROM THE EOR- TWOMEY. | | | | | | A) INDICATE HOW O/A IS BEING PROVIDED TO THE SPACE AND | | | HOW IS IS BEING CONTROLLED- TABLE 403.3.1.1 FBC M, AND | | | SECTION C403.2.4.2 FBC EC. | | | | | | B) SHOW THE LOCATION OF THE THERMOSTAT THAT IS | | | CONTOLLING THE TEMPERATURE IN THE NEW SPACE- SECTION | | | C403.2.4.1 FBC EC. | | | | | | C) THE PLAN INDICATES RETURN AIR VIA A PLENUM CEILING. | | | PLEASE PLACE A NOTE PURSUANT TO SECTION 606.2.1 | | | REGARDING ALLOWABLE MATERIALS IN THE PLENUM SPACE. | | | | | | D) SHOW THE RETURN AIR PATH FROM THE NEW TENANT SPACE | | | BACK TO THE AIR HANDLER- SECTION 601.6 FBC M. | | | | | | 3) MEPP-1: PROVIDE AN ENLARGED DETAIL SHOWING THE | | | TRANSITION DUCT AND THE 16 ROUND DUCT CONNECTIONS TO | | | THE EXISTING FIRE DAMPER- SECTION 607.5.3 FBC M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-05-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-05-21 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-05-21 |
Time |
15:01 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-04-09 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-04-09 |
Time |
10:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-02-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-02-22 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-02-22 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2018-02-22 13:04:26 | MECHANICAL PROVISOS: | | | CCOLE- 2/22/18 | | | | | | 1) MANUFACTURER'S SPECIFICATIONS AND INSTALLATION | | | INSTRUCTIONS FOR THE FIRE DAMPER SHALL BE ONSITE AT | | | TIME OF INSPECTION. | | | | | | 2) SEPARATE PERMIT FOR TENANT BUILD-OUT REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-12-11 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-12-11 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2018-12-11 16:56:12 | PLUMBING PROVISO: SHALL COMPLY PRIOR TO 1ST ROUGH | | | INSPECTION. | | | | | | 1. PROVIDE TEMPERED WATER AT THE LAVATORY. | | | FBC PL 416.5 TEMPERED WATER SHALL BE DELIVERED FROM | | | LAVATORIES AND GROUP WASH FIXTURES LOCATED IN PUBLIC | | | TOILET FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA B125.3. | | | FBC PL 607.1 HOT OR TEMPERED WATER WHERE REQUIRED. IN | | | NONRESIDENTIAL OCCUPANCIES, HOT WATER SHALL BE SUPPLIED | | | FOR CULINARY PURPOSES, CLEANSING, LAUNDRY OR BUILDING | | | MAINTENANCE PURPOSES. IN NONRESIDENTIAL OCCUPANCIES, | | | HOT WATER OR TEMPERED WATER SHALL BE SUPPLIED FOR | | | BATHING AND WASHING PURPOSES. | | | 2. FBC ACC 604.7 TOILET PAPER DISPENSERS SHALL COMPLY | | | WITH 309.4 AND SHALL BE 7 INCHES MINIMUM AND 9 INCHES | | | MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE | | | CENTERLINE OF THE DISPENSER. | | | 3. FBC ACC 609.4 GRAB BARS SHALL BE INSTALLED IN A | | | HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF | | | THE GRIPPING SURFACE. | | | 4. A WATER FOUNTAIN AND SERVICE SINK ARE REQUIRED PER | | | FBC PL TABLE 403.1 | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2018-11-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-11-06 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-11-06 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2018-11-06 14:03:27 | 4TH REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE TEMPERED WATER AT THE LAVATORY. AND HAND | | | SINK. HOT WATER AT A SERVICE SINK. | | | FBC PL 416.5 TEMPERED WATER SHALL BE DELIVERED FROM | | | LAVATORIES AND GROUP WASH FIXTURES LOCATED IN PUBLIC | | | TOILET FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA B125.3. | | | FBC PL 607.1 HOT OR TEMPERED WATER WHERE REQUIRED. IN | | | NONRESIDENTIAL OCCUPANCIES, HOT WATER SHALL BE SUPPLIED | | | FOR CULINARY PURPOSES, CLEANSING, LAUNDRY OR BUILDING | | | MAINTENANCE PURPOSES. IN NONRESIDENTIAL OCCUPANCIES, | | | HOT WATER OR TEMPERED WATER SHALL BE SUPPLIED FOR | | | BATHING AND WASHING PURPOSES. | | | 2. FBC ACC 604.7 TOILET PAPER DISPENSERS SHALL COMPLY | | | WITH 309.4 AND SHALL BE 7 INCHES MINIMUM AND 9 INCHES | | | MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE | | | CENTERLINE OF THE DISPENSER. | | | 3. FBC ACC 609.4 GRAB BARS SHALL BE INSTALLED IN A | | | HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF | | | THE GRIPPING SURFACE. | | | 4. A WATER FOUNTAIN AND SERVICE SINK ARE REQUIRED PER | | | FBC PL TABLE 403.1 | | | | | | NEW COMMENT: | | | | | | 1. THE ADDTIONAL HAND SINK SHALL CONNECT TO BUILDING | | | DRAIN DOWN STREAM OF THE BATHROOM GROUP. PER FBC PL | | | 912.1 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-05-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-05-22 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-05-22 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2018-05-22 13:17:15 | PLUMBING PROVISO: SHALL COMPLY PRIOR TO 1ST ROUGH | | | INSPECTION. | | | | | | 1. PROVIDE TEMPERED WATER AT THE LAVATORY. | | | FBC PL 416.5 TEMPERED WATER SHALL BE DELIVERED FROM | | | LAVATORIES AND GROUP WASH FIXTURES LOCATED IN PUBLIC | | | TOILET FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA B125.3. | | | FBC PL 607.1 HOT OR TEMPERED WATER WHERE REQUIRED. IN | | | NONRESIDENTIAL OCCUPANCIES, HOT WATER SHALL BE SUPPLIED | | | FOR CULINARY PURPOSES, CLEANSING, LAUNDRY OR BUILDING | | | MAINTENANCE PURPOSES. IN NONRESIDENTIAL OCCUPANCIES, | | | HOT WATER OR TEMPERED WATER SHALL BE SUPPLIED FOR | | | BATHING AND WASHING PURPOSES. | | | 2. FBC ACC 604.7 TOILET PAPER DISPENSERS SHALL COMPLY | | | WITH 309.4 AND SHALL BE 7 INCHES MINIMUM AND 9 INCHES | | | MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE | | | CENTERLINE OF THE DISPENSER. | | | 3. FBC ACC 609.4 GRAB BARS SHALL BE INSTALLED IN A | | | HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF | | | THE GRIPPING SURFACE. | | | 4. A WATER FOUNTAIN AND SERVICE SINK ARE REQUIRED PER | | | FBC PL TABLE 403.1 | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-09 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-09 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2018-04-09 10:25:04 | PLUMBING PROVISO: | | | | | | 1. PROVIDE TEMPERED WATER AT THE LAVATORY. | | | FBC PL 416.5 TEMPERED WATER SHALL BE DELIVERED FROM | | | LAVATORIES AND GROUP WASH FIXTURES LOCATED IN PUBLIC | | | TOILET FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA B125.3. | | | FBC PL 607.1 HOT OR TEMPERED WATER WHERE REQUIRED. | | | IN NONRESIDENTIAL OCCUPANCIES, HOT WATER SHALL BE | | | SUPPLIED FOR CULINARY PURPOSES, CLEANSING, LAUNDRY OR | | | BUILDING MAINTENANCE PURPOSES. IN NONRESIDENTIAL | | | OCCUPANCIES, HOT WATER OR TEMPERED WATER SHALL BE | | | SUPPLIED FOR BATHING AND WASHING PURPOSES. | | | 1. FBC ACC 604.7 | | | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | | SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT | | | OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE | | | DISPENSER. | | | 2. FBC ACC 609.4 GRAB BARS SHALL BE INSTALLED IN A | | | HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF | | | THE GRIPPING SURFACE | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-03-06 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-03-06 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-03-06 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2018-03-06 16:00:34 | DENIED | | | 1. AIR ADMITTANCE VALVE MUST BE AN APPROVED DEVICE THAT | | | MEETS THE POSITIVE AND NEGATIVE PRESSURE ON A FIVE OR | | | MORE MULTI-STORY BUILDING, IF NOT APPROVE IT CANNOT BE | | | USED ON THE FIRST FLOOR IN ACCORDANCE WITH THE | | | REQUIREMENTS OF THE MANUFACTURES SPECIFICATION UNLESS | | | WILLING TO PAY THE COST OF THE DEVICE THAT MEETS THOSE | | | REQUIREMENTS. FBC P 918.2 INSTALLATION AND FBC P | | | 918.3.1 HORIZONTAL BRANCHES. | | | 2. HOT WATER DEVICE NOT SHOWN, PLEASE PROVIDE DETAIL | | | AND SIZING FBC P 607.1 WHERE REQUIRED. | | | 3. TEMPERED WATER REQUIRED AND DETAILS OF A TEMPERATURE | | | LIMITING DEVICE THAT CONFORMS TO ASSE 1070 FBC P | | | 607.1.2 TEMPERED WATER TEMPERATURE CONTROL. | | | 4. ADA DETAIL OF HEIGHTS AND DIMENSION NOT SHOWN, | | | PLEASE PROVIDE DETAIL DRAWINGS PER 2017 FBC | | | ACCESSIBILITY CODE. | | | 5. THERE IS NO CLEAN OUT AT THE 4? CONNECTION OF THE | | | BUILDING 2017 FBC P 708.1.3 BUILDING DRAIN AND BUILDING | | | SEWER JUNCTION. | | | 6. PLEASE DARKEN DIMENSION FOR TOILET ROOM PAGE A-1, | | | THEY ARE ILLEGIBLE WPB AMENDMENTS TO THE FBC SEC. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | 7. PLEASE GIVE DIMENSIONS FOR FIXTURE CLEARANCES PER | | | FLORIDA BUILDING CODE AND FLORIDA ACCESSIBILITY CODE. | | | 8. PLEASE GIVE THE LEVEL OF ALTERATION PER 2017 FLORIDA | | | EXISTING BUILDING CODE 301.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | [email protected] | | | 561-805-6720 | | | |
|
|