 |
Plan Review Details - Permit 18020313
| Plan Review Stops For Permit 18020313 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-08-13 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-08-13 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-08-13 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-04-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-30 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-30 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-03-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-03-12 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-03-09 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2018-03-12 07:14:34 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE WINDOW AND DOOR SCHEDULE. | | | 2. PROVIDE DESIGN WIND LOADS FOR PROPOSED OPENINGS. | | | 3. PROVIDE PRO9DUCT APPROVALS FO0R PROPOSED WINDOWS AND | | | DOORS. | | | 4. VALUE APPEARS LOW. | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-R301.2. | | | | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). THE STRUCTURAL PROVISIONS OF | | | THIS CODE FOR WIND LOADS ARE NOT PERMITTED WHERE WIND | | | DESIGN IS REQUIRED AS SPECIFIED IN SECTION R301.2.1.1. | | | WHERE DIFFERENT CONSTRUCTION METHODS AND STRUCTURAL | | | MATERIALS ARE USED FOR VARIOUS PORTIONS OF A BUILDING, | | | THE APPLICABLE REQUIREMENTS OF THIS SECTION FOR EACH | | | PORTION SHALL APPLY. WHERE NOT OTHERWISE SPECIFIED, THE | | | WIND LOADS LISTED IN TABLE R301.2(2) ADJUSTED FOR | | | HEIGHT AND EXPOSURE USING TABLE R301.2(3) SHALL BE USED | | | TO DETERMINE DESIGN LOAD PERFORMANCE REQUIREMENTS FOR | | | WALL COVERINGS, CURTAIN WALLS, ROOF COVERINGS, EXTERIOR | | | WINDOWS, SKYLIGHTS AND EXTERIOR DOORS (OTHER THAN | | | GARAGE DOORS). | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. | | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | | | | CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-07-24 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-07-24 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-07-24 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2018-07-24 14:27:04 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: OK,. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-04-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-04-30 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-04-30 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2018-07-24 14:22:19 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: OK,. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | | | | | | | | | 2018-04-30 09:19:47 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | 3. PROVIDE SMOKE ALARMS IN EACH LOCATION REQUIRED PER | | | CODE. SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE | | | EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC | | | R314.3, FBC 107.2.1 (A SMOKE ALARM IS REQUIRED ON EACH | | | STORY OF THE DWELLING, NONE IS SHOWN ON THE LOWER | | | LEVEL. PROVIDE CORRECTION.) | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. PROVIDE GFCI RECEPTACLE OUTLET FOR BALCONIES. NEC | | | 210.52(E)(3) (NOT PROVIDED. PER CODE: BALCONIES, DECKS, | | | AND PORCHES THAT ARE ATTACHED TO THE DWELLING UNIT AND | | | ARE ACCESSIBLE FROM INSIDE THE DWELLING UNIT SHALL HAVE | | | AT LEAST ONE RECEPTACLE OUTLET ACCESSIBLE FROM THE | | | BALCONY, DECK, OR PORCH. PROVIDE CORRECTION.) | | | 7. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC RE | | | E3706.2, E3902 (NOT PROVIDED.) | | | 8. CORRECTED. | | | | | | NEW COMMENT: | | | | | | 9. GFCI RECEPTACLE OUTLET PROVIDED ON PENINSULA APPEARS | | | TO BE UNDER AN OVERHANG THAT EXTENDS MORE THAN 6 INCHES | | | FROM ITS SUPPORT BASE. WHILE A RECEPTACLE IS PERMITTED | | | IN THIS LOCATION, IT DOES NOT FULFILL CODE REQUIREMENT | | | FOR THE PENINSULA. PROVIDE CORRECTION. NEC 210.52(C)(5) | | | 10. PLEASE BE ADVISED THAT SOME COMMENTS HAVE NOT BEEN | | | ADDRESSED FOR TWO REVIEWS. IF UPON THE THIRD REVIEW, IF | | | IT IS NECESSARY TO REJECT THE SUBMITTED PLAN A THIRD | | | TIME FOR THE SAME REASONS, AN ADDITIONAL PLAN REVIEW IS | | | REQUIRED. FLORIDA STATUTES STATE: ?WITH RESPECT TO | | | EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A | | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B)? | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-02-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-02-26 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-02-26 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2018-02-26 15:57:48 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. THE NEC AND FBC SPECIFIED FOR DESIGN IS NOT THE | | | CURRENT CODE. PROVIDE CORRECTION. FBC PREFACE (ALSO SEE | | | CURRENT CODES ABOVE) | | | 2. VALUE OF WORK APPEARS LOW. PROVIDE COPY OF SIGNED | | | CONTRACT WITH SCOPE AND VALUE OF WORK, TO INCLUDE ALL | | | MATERIALS AND LABOR. FBC 109.3 | | | 3. PROVIDE SMOKE ALARMS IN EACH LOCATION REQUIRED PER | | | CODE. SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE | | | EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC | | | R314.3, FBC 107.2.1 | | | 4. PROVIDE CORRECTION FOR NOTE 18 TO INCLUDE: ?BRANCH | | | CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- AND | | | 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, | | | DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, | | | BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED.? NEC 210.12; FBC RE E3902.16 | | | 5. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 6. PROVIDE GFCI RECEPTACLE OUTLET FOR BALCONIES. NEC | | | 210.52(E)(3) | | | 7. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC RE | | | E3706.2, E3902 | | | 8. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC | | | 215.5; FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2018-08-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-30 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-08-30 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2018-09-04 11:29:56 | APPROVED BY | | | JERALD SMITH 0017-P | | | PLUMBING PLANS EXAMINER | | | 561-805- 6711 | | 2018-08-30 10:20:29 | APPROVED |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-04-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-26 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-26 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2018-04-26 12:11:40 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | 2. THE TANKLESS HEATER SHALL BE MOUNTED A MIN OF 4' | | | FROM ANY OPENING IN BUILDING. PER MANUFACTURE SPEC | | | | | | 3. SHOW ON THE RISER THE LENGTH OF EACH CUT SECTION OF | | | PIPE FROM METER TO MOST REMOTE APPLIANCE. FBC-2017 FUEL | | | GAS, SECS. 402.4.1, 402.4.2. | | | | | | 4. THE TANKLESS WATER HEATER IS NOT SHOWN ON THE GAS | | | RISER IT IS SHOWN ON SHT A-1 NEXT TO THE AC UNITS | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 5. PLEASE SHOW METER ON THE FLOOR PLAN. PER WPB AMEND | | | TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-03-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-03 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-03 |
Time |
07:10 |
Sent To |
|
|
| Notes |
| 2018-03-03 07:11:22 | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT AND PLANS IS REQUIRED FOR THE GAS | | | INSTALLATION OR MODIFICATION OF SYSTEM. | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-05-02 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-05-02 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-02-13 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-02-13 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-02-13 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-08-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-30 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-11 |
Time |
16:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-05-02 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-04-13 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-03-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-03-12 |
Time |
07:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-02-07 |
Time |
10:47 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2018-08-13 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-08-13 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-08-13 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2018-08-13 16:04:42 | THERE IS NO MECHANICAL WORK SHOWN EXCEPT THE | | | INSTALLATION OF AN ADDITIONAL CU. ANY/ALL MECHANICAL | | | SHALL BE BY SEPARATE SUBMITTAL. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-04-17 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-04-17 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-04-17 |
Time |
14:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-03-07 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-03-07 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-03-07 |
Time |
15:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-08-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-30 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-08-30 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2018-09-04 11:30:57 | APPROVED BY | | | JERALD SMITH 0017-P | | | PLUMBING PLANS EXAMINER | | | 561-805- 6711 | | 2018-08-30 10:17:49 | PLANS APPROVED FOR PERMIT, HOWEVER, THE KITCHEN SINK | | | WAS INADVERTENTLY LEFT OFF OF THE SANITARY ISOMETRIC. | | | PROVIDE REVISED SANITARY ISOMETRIC TO SHOW KITCHEN SINK | | | AND SUBMIT | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-04-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-26 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-26 |
Time |
06:03 |
Sent To |
|
|
| Notes |
| 2018-04-26 11:41:03 | 2ND REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. A-1 THE NOTE ON THE PLUMBING RISER STATING THE | | | PLUMBING LAYOUT WILL BE SUBMITTED AFTER THE | | | INSTALLATION WILL NOT COMPLY IN ORDER FOR A PLUMBING | | | PERMIT TO BE ISSUED A CODE COMPLIANT SANITARY ISOMETRIC | | | SHALL BE SUBMITTED AND APPROVED. 107.3.5.3(12) | | | | | | 2. SHT. A-1 THE SANITARY ISOMETRIC PLEASE CORRECT THE | | | FOLLOWING | | | A) THE WASTE STACK FOR THE 2ND FLOOR MASTERBATH | | | LAVATORY'S, TUB AND WASHING MACHINE SHALL CONNECT TO | | | THE BUILDING DRAIN SEPARATELY FROM THE POWDER ROOM BATH | | | WET VENT. | | | B) THE WASHING MACHINE BRANCH DRAIN SHALL CONNECT TO | | | THE WASTE STACK DOWN STREAM OF THE LAVATORY'S AND TUB. | | | C) THE POWDER ROOM TOILET SHALL BE VENTED BY THE | | | LAVATORY STACK BEFORE CONNECTING TO THE BUILDING DRAIN. | | | PER FBC RES P3108.1 | | | | | | 3. SHT. A-1 PLACE NOTE ON PLAN SHUT OFF VALVES FOR THE | | | STACKABLE WASHING MACHINE SHALL BE ACCESSIBLE. PER FBC | | | PL P2903.9.3 | | | | | | 4. THE PLUMBING AND GENERAL CONTRACTORS WORKMENS COMP | | | INS AND LIBILITY INS NEEDS TO BE UPDATED WITH THE CITY | | | OF WPB BEFORE A PERMITS CAN BE ISSUED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-03-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-03 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-02 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2018-03-03 07:26:29 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. A CODE COMPLIANT RISER DIAGRAM IS REQUIRED ON A | | | RESIDENTIAL SET OF PLANS FOR APPROVAL. PER WPB AMEND TO | | | FBC 107.3.5.3(11) | | | | | | 2.THE WATER CLOSET IN THE POWDER-ROOM IS NOT VENTED IT | | | SHALL BE VENTED AS A WET VENT BY THE LAVATORY WITH A | | | SEPARATE VENT THRU 2ND FLOOR OR BE INDIVIDUAL DRY VENT. | | | PER FBC RES P3106.1, P3108.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-05-02 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-05-02 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-02-13 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-02-13 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-02-13 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |