Plan Review Details - Permit 18020219
| Plan Review Stops For Permit 18020219 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-02-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-02-26 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-02-26 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2018-02-26 13:30:13 | 2017 FBC | | | CONSTRUCTION TYPE: I-A | | | SUITE 200 2072 SQ. FT. 21 OCC. LOAD | | | SUITE 202 1437 SQ. FT. 15 OCC. LOAD | | | SUITE 203 1581 SQ. FT. 16 OCC. LOAD | | | SUITE 204 1231 SQ. FT. 13 OCC. LOAD | | | TOTAL SQ. FT. 6321 65 TOTAL OCC. LOAD | | | | | | BUSINESS OCCUPANCY | | | | | | SPRINKLERED/ YES | | | | | | RESTROOMS 2 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-03-23 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-03-23 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-03-23 |
Time |
15:20 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-03-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-03-16 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-03-16 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2018-03-16 08:56:21 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. FEED FROM DISCONNECT TO TRANSFORMER T1A IS SHOWN | | | WITH FOUR 3/0 AND ONE #2 WIRE. THIS FEED SHOULD NOT | | | INCLUDE A NEUTRAL CONDUCTOR (GROUNDED CONDUCTOR) AS | | | THIS WOULD CREATE A POSSIBILITY OF OBJECTIONABLE | | | CURRRENT. THIS FEED SHOULD HAVE ONLY THE THREE PHASE | | | CONDUCTORS AND AN EQUIPMENT GROUNDING CONDUCTOR. | | | PROVIDE CORRECTION. NEC 250.6, 250.30 | | | 2. THE NEC AND FBC SPECIFIED FOR DESIGN IS NOT THE | | | CURRENT CODE. PROVIDE CORRECTION. FBC PREFACE (ALSO SEE | | | CURRENT CODES ABOVE) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-02-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-02-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-02-12 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2018-02-12 15:28:51 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) SHEET T - THERE ARE INDICATIONS OF INCORRECT | | | EDITIONS OF THE FLORIDA FIRE PREVENTION CODE. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 6TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2015 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | | | | PLEASE ENSURE COMPLIANCE AND ADJUST YOUR RECORDS | | | ACCORDINGLY. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-03-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-03-22 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2018-03-23 14:49:24 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-03-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-17 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-06 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2018-02-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-02-26 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-02-26 |
Time |
13:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-02-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-02-08 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-02-07 |
Time |
17:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-03-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-17 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-17 |
Time |
08:58 |
Sent To |
|
|
| Notes |
|
|
|