 |
Plan Review Details - Permit 18020210
| Plan Review Stops For Permit 18020210 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-03-28 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-03-28 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-03-28 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-03-09 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-03-09 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-03-09 |
Time |
12:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-02-14 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-02-14 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-02-14 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2018-02-14 15:03:30 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | | | | 561-805-6718 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2017 6TH EDITION W/2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION / FRC FLORIDA RESIDENTIAL CODE | | | 2017 6TH EDITION | | | | | | 1. ONE SET OF PLANS NOT SIGNED AND SEALED BY WILLIAM | | | TRACY ARCHITECT. | | | | | | 61G1-16.001 ARCHITECTS AND INTERIOR DESIGNERS SEAL. | | | EACH ARCHITECT AND INTERIOR DESIGNER SHALL ACQUIRE A | | | SEAL WITH WHICH SHE OR HE SHALL IDENTIFY ALL PLANS, | | | SPECIFICATIONS OR REPORTS PREPARED OR ISSUED BY HER OR | | | HIM AND FILED FOR PUBLIC RECORD. THE SEAL SHALL BE | | | CAPABLE OF LEAVING A PERMANENT INK REPRESENTATION OR | | | OTHER FORM OF EMBOSSING OR OPAQUE AND PERMANENT | | | IMPRESSION, WHICH ALSO MAY BE COMPUTER GENERATED | | | IMPRESSIONS, ON THE SURFACE OF PRINTS OR OTHER | | | DUPLICATIONS OF DRAWINGS, AND, AS APPROPRIATE, UPON | | | SPECIFICATION PAGES, AND OTHER ARTICLES OF SERVICE. | | | WHERE REQUIRED, ELECTRONIC FILES MAY BE SEALED IN | | | ACCORDANCE WITH RULE 61G1-16.005, F.A.C. | | | | | | 2. PROVIDE THE FLAME SPREAD INDEX FOR THE US FLOORS | | | SOUND PROOFING THAT WILL BE USED. | | | FBC 603.1 FLAME SPREAD ? ASTM E-84-09 | | | | | | 3. PROVIDE EXISTING AND NEW STUD SPACING AT SHOWER WALL | | | LOCATIONS AND INCLUDE TYPE OF BOARD THAT WILL BE USED. | | | NOTE: MANY CEMENT BOARD MANUFACTURERS REQUIRE A MINIMUM | | | OF 16 INCHES ON CENTER FOR FRAMING. | | | FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-04-03 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-04-03 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-04-03 |
Time |
14:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-03-22 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-03-22 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-03-22 |
Time |
13:07 |
Sent To |
P |
|
| Notes |
| 2018-03-22 12:55:03 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | 3. CORRECTED. | | | 4. PLAN PROVIDED DOES NOT SHOW ALL WORK DESCRIBED IN | | | ATTACHED CONTRACT. SHOW ALL ELECTRICAL WORK ON PLAN. | | | FBC 107.2.1, 107.3.5 (NOT CORRECTED) | | | 5. PROVIDE PANEL SCHEDULE INDICATING SIZE OF PANEL, ANY | | | NEW OR ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR | | | THESE CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE | | | APPLICABLE TO COMPLY WITH CODE. NEC 210.8, 210.12, | | | 215.5, 408.4(NOT ALL CIRCUITS SHOWN) | | | 6. PROVIDE LOAD CALCULATION FOR SERVICE AND FOR | | | INDIVIDUAL UNIT, INCLUDE EXISTING AND NEW LOADS TO | | | CONFIRM CAPACITY OF SERVICE IS ADEQUATE. NEC 215.2, | | | 220, 408.30 (CALCULATION PROVIDED IS NOT PER CODE, | | | INCLUDE LOAD FOR TANKLESS WATER HEATER. ALSO PROVIDE | | | LOAD CALC FOR BUILDING SERVICE TO CONFIRM THAT THE | | | EXISTING SERVICE IS ADEQUATE FOR ADDITION OF TANKLESS | | | LOAD.) | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. CORRECTED. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-02-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-02-26 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-02-26 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2018-02-26 12:38:00 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. IN NOTE 4 AND THE DESIGN BLOCK THE PLAN SHOWS THE | | | 2011 NEC FOR DESIGN. THE NEC SPECIFIED FOR DESIGN IS | | | NOT THE CURRENT CODE. PROVIDE CORRECTION. FBC PREFACE | | | (ALSO SEE CURRENT CODES ABOVE) | | | 2. CARBON MONOXIDE DETECTORS ARE SHOWN IN WRONG | | | LOCATION. PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET | | | OF EACH ROOM USED FOR SLEEPING PURPOSES. FBC R315.1 | | | 3. PER THE 2014 NEC: ?BRANCH CIRCUITS THAT SUPPLY | | | 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS | | | INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, | | | LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, | | | SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, | | | LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI | | | PROTECTED.? PROVIDE CORRECTION FOR ANY NEW OR ALTERED | | | CIRCUITS, A NOTE WILL SUFFICE. NEC 210.12 | | | 4. PLAN PROVIDED DOES NOT SHOW ALL WORK DESCRIBED IN | | | ATTACHED CONTRACT. SHOW ALL ELECTRICAL WORK ON PLAN. | | | FBC 107.2.1, 107.3.5 | | | 5. PROVIDE PANEL SCHEDULE INDICATING SIZE OF PANEL, ANY | | | NEW OR ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR | | | THESE CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE | | | APPLICABLE TO COMPLY WITH CODE. NEC 210.8, 210.12, | | | 215.5, 408.4 | | | 6. PROVIDE LOAD CALCULATION FOR SERVICE AND FOR | | | INDIVIDUAL UNIT, INCLUDE EXISTING AND NEW LOADS TO | | | CONFIRM CAPACITY OF SERVICE IS ADEQUATE. NEC 215.2, | | | 220, 408.30 | | | 7. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC EC R404.1 | | | 8. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC 210.8(D) | | | 9. BOTH COPIES OF PLAN ARE REQUIRED TO BE SIGNED BY THE | | | PERSON RESPONSIBLE FOR THE DESIGN. FS 471, 481; FBC | | | 107.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2018-03-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-03-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-03-28 |
Time |
14:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-03-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-03-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-03-09 |
Time |
15:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-02-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-02-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-02-09 |
Time |
10:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-04-05 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-04-05 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-03-26 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-03-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-23 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-07 |
Time |
10:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-03-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-02 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-07 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2018-02-14 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-02-14 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-02-14 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2018-02-14 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-02-14 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-02-14 |
Time |
14:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-04-05 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-04-05 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-04-05 |
Time |
17:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-03-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-23 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-23 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2018-03-23 13:35:13 | 2ND REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. NEW PLAN SHEET SHOW WATER HEATER AS EXISTING THE | | | SCOPE OF WORK STATES THE EXISTING WATER HEATER TO BE | | | REPLACED WITH A TANKLESS WATER HEATER PLEASE CLARIFY. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. THE SCOPE OF WORK IS STATING TWO TYPES OF WATER | | | HEATER THE PLANS AND SCOPE OF WORK NEED TO BE CLEAR AS | | | TO WHICH TYPE IS BEING INSTALLED YOU WILL NEED TO | | | DETERMINE YOUR ELECTRIC LOAD WILL BE TO HIGH. BEFORE | | | RESUBMITTING. PER WPB AMEND TO FBC 107.2.1.3 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-03-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-02 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-02 |
Time |
09:37 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |