Plan Review Details - Permit 18020036
| Plan Review Stops For Permit 18020036 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-02-21 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-02-21 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-02-16 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2018-02-20 10:47:58 | RESUB ROUTED TO LCRESPO |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-02-07 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-02-07 |
Time |
06:35 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-02-01 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2018-02-02 12:35:24 | ROUTED TO PLUMBING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-02-21 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-02-21 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-02-21 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2018-02-21 07:28:37 | APPROVED BY PLUMBING AND SENT TO PROCESSING, LAC |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-02-07 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-02-07 |
Time |
06:35 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-02-07 |
Time |
06:35 |
Sent To |
|
|
| Notes |
| 2018-02-07 06:40:37 | DENIED | | | | | | PLUMBING REPAIR TUNNEL WORK | | | | | | A CLEAR AND LEGIBLE SANITARY RISER DIAGRAM SHALL BE | | | SUBMITTED SHOWING ALL PIPE SIZES, CONNECTION POINTS TO | | | EXISTING PIPING, HOW THE NEW PIPE WILL BE SUPPORTED, | | | THE TYPE OF ADAPTERS USED FOR THE CONNECTIONS TO | | | EXISTING PIPE, AND THE LOCATIONS OF REQUIRED CLEANOUTS. | | | DETAILS AND BACKFILLING PROCEDURES SHALL BE SUBMITTED | | | THAT CLEARLY SHOW HOW THE STRUCTURAL INTEGRITY OF THE | | | CONCRETE SLAB WILL BE MAINTAINED DURING EXCAVATION AND | | | BACKFILLING. STRUCTURAL FOAM IS NOT PERMITTED BELOW | | | GROUND PER THE 2017 FLORIDA BUILDING CODE, RESIDENTIAL, | | | SECTION 318.8 AND THE 2017 FLORIDA BUILDING CODE, | | | BUILDING, SECTION 2603.9. | | | A SIGNED AND SEALED LETTER FROM AN ENGINEER MAY BE | | | REQUIRED TO CERTIFY THE STRUCTURAL INTEGRITY OF THE | | | EXISTING SLAB. | | | THE BACKFILL UNDER THE SLAB SHALL BE TREATED FOR | | | TERMITES PER THE 2017 FBC B SEC.1816.1 OR 2017 FBC R | | | SEC. 318.1. A TERMITE CERTIFICATE SHALL BE ONSITE FOR | | | FINAL INSPECTION. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | [email protected] | | | 561-805-6720 | | | |
|
|
|