| Plan Review Stops For Permit 18011280 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-03-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-03-15 |
Time |
18:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-03-15 |
Time |
18:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-03-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-03-08 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-03-08 |
Time |
07:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-02-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-02-14 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-02-14 |
Time |
06:41 |
Sent To |
|
|
| Notes |
| 2018-02-14 07:22:05 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE AMERICAST GENERATOR PAD PLANS HAVE SEVERAL | | | REFERENCES TO THE FBC FIFTH EDITION (2014). THE FBC | | | SIXTH EDITION (2017) WENT INTO EFFECT ON JANUARY 1, | | | 2018. ALL NEW PERMITS APPLIED FOR ON OR AFTER THAT DATE | | | ARE REQUIRED TO COMPLY WITH AND REFERENCE THE FBC SIXTH | | | EDITION (2017). |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-02-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-02-15 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-02-15 |
Time |
10:48 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2018-03-15 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-03-15 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-03-15 |
Time |
16:13 |
Sent To |
B |
|
| Notes |
| 2018-03-15 16:15:25 | 03/15/18 APPROVED BY PLUMBING AND SENT TO BUILDING RM, | | | LAC |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-03-07 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-03-07 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-03-06 |
Time |
06:36 |
Sent To |
|
|
| Notes |
| 2018-03-07 10:28:24 | 1) THE PIPING SYSTEM SHALL BE SIZED TO MEET THE MAXIMUM | | | DEMAND TO EACH APPLIANCE. 2017 FBC-FUEL GAS SECS. | | | 402.1, 402.2.. THE GAS PLAN SHOWS A BTU LOAD OF 191,000 | | | BTU'S YET THE GENERATOR SPECS SHOW A BTU LOAD OF | | | 300,000 BTU'S AT FULL LOAD. THE GAS SYSTEM SHALL BE | | | SIZED FOR THE 300,000 BTU LOAD. | | | 2) THE GAS PLAN SHOWS A 1/2 LB. PRESSURE GAS SYSTEM BUT | | | THE SUBMITTED SITE PLAN SHOWS A 2 PSI GAS METER. | | | CLARIFY. | | | 3) THE GAS PLAN SHOWS A NATURAL GAS METER AND NOTES A | | | NATURAL GAS SYSTEM, BUT THE PLAN ALSO NOTES AN LP GAS | | | SYSTEM. CLARIFY. | | | 4) IF THIS IS TO BE A 1/2 LB. GAS SYSTEM, THE ENTIRE | | | PIPING SYSTEM IS UNDERSIZED. COMPLY WITH 2017 FBC-FUEL | | | GAS SEC.402.3. | | | 5) THE SUBMITTED GAS TABLES ARE BOTH FOR LESS THAN A 2 | | | PSI SYSTEM, BUT THE SITE PLAN SHOWS A 2 PSI METER. | | | CLARIFY. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-02-16 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-02-16 |
Time |
07:08 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-02-16 |
Time |
07:08 |
Sent To |
|
|
| Notes |
| 2018-02-16 07:26:40 | 02/16/2018 GAS 1ST REVIEW**DENIED** | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1) GAS REGULATOR MANUAL PROVIDED IS MISSING PAGES 4-10. | | | COMPLETE MANUAL IS REQUIRED, 2017 FBC- FUEL GAS 410.1 | | | | | | 2) REQUIRED SEDIMENT TRAP FOR THE GENERATOR IS MISSING | | | ON YOUR ISOMETRIC PLAM AND I WAS UNABLE TO LOCATE ONE | | | BUILT IN THE GENERATOR FROM THE MANUAL SUPPLIED. 2017 | | | FBC FUEL GAS 408.4 | | | | | | 3) YOUR ISOMETRIC DRAWING LIST THE CORRECT 2017 FBC | | | FUEL AND GAS CODE BUT THE COPIES OF THE SIZING CHARTS | | | PROVIDED SHOW 2014. PROVIDE CORRECT COPIES LISTED AS | | | 2017. FBC 107.2.1 | | | | | | 4) YOUR ISOMETRIC PLAN SHOW A NEW 500 GALLON L.P TANK | | | BUT ON YOUR FLAT DRAWING YOU SHOW A NEW NAT GAS METER | | | AS BEING THE SOURCE OF GAS PROVIDED. PLEASE CLARIFY | | | WHICH GAS IS BEING USED. FBC 107.2.1 | | | | | | 5) CLEARLY SHOW THE LOCATION AND CAPACITY OF LP | | | TANK(S), TYPE OF TANK (DOT OR ASME), THE DISTANCE OF | | | THE TANK FROM THE EXTERIOR BUILDING WALL AND ADJACENT | | | PROPERTY LINES, THE DISTANCE OF THE TANK FROM ALL | | | SOURCES OF IGNITION, OTHER CONTAINERS, BUILDINGS, AND | | | THE LOCATION OF ANY BUILDING OPENINGS BELOW THE RELIEF | | | VALVE OF THE TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | 6) CLEARLY INDICATE ON THE PLAN IF THE LP TANK IS ABOVE | | | GROUND OR BELOW GROUND, AND SHOW THE METHOD OF REQUIRED | | | PROTECTION FOR THE LP TANK AND APPURTENANCES PER NFPA | | | 58. IF THE TANK IS BELOW GROUND IT SHALL BE ANCHORED | | | PER NFPA 58 SEC.3-2.2.7 (H). IF ABOVE GROUND, THE TANK | | | SHALL BE SECURELY ANCHORED TO WITHSTAND 170 MPH ULT | | | WIND LOAD PER THE FLORIDA BUILDING CODE. | | | | | | 7) ) SHOW THE DEPTH OF THE LP GAS CONTAINER BELOW | | | GRADE. COMPLY WITH NFPA 58 SEC. 6.6.6.1. | | | | | | 8) PROVIDE THE SIZE OF THE HOLD-DOWN CABLES/STRAPS FOR | | | THE TANK AND THE TYPE AND LENGTH OF GROUND ANCHORS TO | | | BE INSTALLED TO PREVENT FLOTATION. NFPA 58 SEC. | | | 6.6.1.6. | | | | | | 9) A CATHODIC PROTECTION SYSTEM SHALL BE REQUIRED PER | | | NFPA 58 SECS. 5.2.1.11, 6.6.6.1 (I) AND SHALL BE | | | MONITORED PER NFPA 58 SEC.6.6.6.1 (J). SUBMIT DETAILS | | | ON THE TYPE OF CATHODIC PROTECTION, SIZE (LBS) & NUMBER | | | OF MAGNESIUM BAG(S), SIZE & TYPE OF ANODE CABLE. | | | | | | 10) SHOW THE DISTANCE FROM THE 2 PSI REGULATOR TO THE | | | APPLIANCE. COMPLY WITH 2017 FBC-FUEL GAS TABLE 402.4 | | | (28) FOR THE PROPER PIPE SIZE AND BTU LOAD. | | | | | | TIM HUNT | | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | 561-805-6695 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-03-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-03-27 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-03-21 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2018-03-22 13:12:51 | RESUB ROUTED TO PGREILIC VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-03-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-03-15 |
Time |
18:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-03-13 |
Time |
13:13 |
Sent To |
I |
|
| Notes |
| 2018-03-14 13:13:18 | RESUB ROUTED TO ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-03-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-03-08 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-02-27 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2018-02-28 09:28:51 | RESUB ROUTED TO PGREILIC VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-02-16 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-02-16 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-02-16 |
Time |
07:26 |
Sent To |
I |
|
| Notes |
| 2018-02-01 11:24:46 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-03-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-03-27 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2018-03-27 08:38:16 | 1.) PROVIDE REQUIRED LANDSCAPE SCREENING | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-03-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-03-14 |
Time |
15:26 |
Sent To |
G |
|
| Notes |
| 2018-03-14 15:27:15 | 1.) MECHANICAL EQUIPMENT CANNOT ENCROACH MORE THAN 4 | | | FEET INTO REQUIRED SETBACKS. 21 FEET MINIMUM NEEDED | | | FROM NORTH AND SOUTH PROPERTY LINES | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-03-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-03-02 |
Time |
10:55 |
Sent To |
G |
|
| Notes |
| 2018-03-02 10:55:41 | FAILED | | | | | | 1.) MECHANICAL EQUIPMENT SHALL NOT ENCROACH MORE THAN 4 | | | FEET INTO REQUIRED SETBACKS | | | 2.) LANDSCAPE SCREENING REQUIRED. SHOW ON PLAN | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-02-13 |
|
|
Cont ID |
|
| Sent By |
PG |
Date |
2018-02-13 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-02-07 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2018-02-13 09:03:07 | FAILED | | | | | | 1.) LABEL SETBACK FOR PROPOSED GENERATOR. MECHANICAL | | | EQUIPMENT SHALL NOT ENCROACH MORE THAN 4 FEET INTO | | | REQUIRED SIDE SETBACK | | | 2.) LANDSCAPE SCREENING REQUIRED. SHOW ON PLAN | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] |
|
|