Plan Review Details - Permit 18011193
Plan Review Stops For Permit 18011193
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2018-04-13 Cont ID  
Sent By jgomez Date 2018-04-13 Time 10:16 Rev Time 0.00
Received By jgomez Date 2018-04-13 Time 10:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2018-04-06 Cont ID  
Sent By jgomez Date 2018-04-06 Time 10:31 Rev Time 0.00
Received By jgomez Date 2018-04-06 Time 10:30 Sent To  
Notes
2018-04-06 10:30:48RESIDENTIAL (R3) REVISION FOURTH BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE:
 RECEIVED E-MAIL FROM JOE DARSCH FROM ASTRO AIR INC. THE
 SAME INFORMATION WAS SUBMITTED ON THE THIRD REVIEW WAS
 E-MAILED THIS TIME. NEED TO ADDRESS THE COMMENTS FROM
 THIRD REVIEW. SEE COPY OF COMMENTS BELOW AND RESUBMIT.
  
  
  
 RESIDENTIAL (R3) REVISION THIRD BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED
 AND DATED BY THE OWNER OR OWNER'S LEGALLY DESIGNATED
 AGENT AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 SEC. R103.1.1.2 CODE COMPLIANCE CERTIFICATION.
 THE BUILDING'S OWNER, THE OWNER'S ARCHITECT OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE
 CODE, AS PER SECTION 553.907, FLORIDA STATUTES, PRIOR
 TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION.
  
 2- BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC-RESIDENTIAL.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2018-04-05 Cont ID  
Sent By jgomez Date 2018-04-05 Time 10:01 Rev Time 0.00
Received By jgomez Date 2018-04-05 Time 10:01 Sent To  
Notes
2018-04-05 09:15:39RESIDENTIAL (R3) REVISION THIRD BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED
 AND DATED BY THE OWNER OR OWNER'S LEGALLY DESIGNATED
 AGENT AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 SEC. R103.1.1.2 CODE COMPLIANCE CERTIFICATION.
 THE BUILDING'S OWNER, THE OWNER'S ARCHITECT OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE
 CODE, AS PER SECTION 553.907, FLORIDA STATUTES, PRIOR
 TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION.
  
 2- BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC-RESIDENTIAL.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-02-27 Cont ID  
Sent By jgomez Date 2018-02-22 Time 17:05 Rev Time 0.00
Received By jgomez Date 2018-02-22 Time 15:05 Sent To  
Notes
2018-02-22 15:11:32RESIDENTIAL (R3) REVISION SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- ENERGY CALCULATIONS NEED TO BE REVISED BECAUSE THE
 A/C EQUIPMENT IS OVERSIZED. SEE MECHANICAL COMMENTS
 REGARDING THE A/C EQUIPMENT SIZING. SEC. R403.6.1.1
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-02-06 Cont ID  
Sent By jgomez Date 2018-02-06 Time 12:41 Rev Time 0.00
Received By jgomez Date 2018-02-06 Time 11:39 Sent To  
Notes
2018-02-06 12:41:27RESIDENTIAL (R3) REVISION BUILDING REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- REVISION DESCRIPTION INDICATES THAT REVISED ENERGY
 CALCULATIONS WERE SUBMITTED. THERE ARE NO ENERGY
 CALCULATIONS IN THIS SUBMITTAL. PROVIDE COMPLETE AND
 CORRECT REVISED ENERGY CALCULATIONS AS REQUESTED ON
 PROVISO DATED 12/19/17.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2018-04-13 Cont ID  
Sent By jgomez Date 2018-04-13 Time 10:17 Rev Time 0.00
Received By jgomez Date 2018-04-13 Time 10:15 Sent To  
Notes
2018-04-13 10:16:32MET WITH STEVE FROM ASTRO AIR AND KEVIN FROM BALDWIN
 INNOVATIVE BUILDERS.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2018-04-06 Cont ID  
Sent By jgomez Date 2018-04-06 Time 10:37 Rev Time 0.00
Received By jgomez Date 2018-04-06 Time 10:28 Sent To  
Notes
2018-04-06 10:30:28RECEIVED E-MAIL FROM JOE DARSCH FROM ASTRO AIR INC.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-04-05 Cont ID  
Sent By jgomez Date 2018-04-05 Time 10:16 Rev Time 0.00
Received By jgomez Date 2018-04-05 Time 08:56 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-02-27 Cont ID  
Sent By jgomez Date 2018-02-22 Time 17:08 Rev Time 0.00
Received By jgomez Date 2018-02-20 Time 10:05 Sent To  
Notes
2018-02-21 10:05:55RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-02-06 Cont ID  
Sent By jgomez Date 2018-02-06 Time 17:46 Rev Time 0.00
Received By jgomez Date 2018-01-30 Time 10:43 Sent To I
Notes
2018-01-31 10:44:14REVISION ROUTED TO JGOMEZ

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2018-04-13 Cont ID  
Sent By jgomez Date 2018-04-13 Time 10:17 Rev Time 0.00
Received By jgomez Date 2018-04-13 Time 10:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2018-04-06 Cont ID  
Sent By jgomez Date 2018-04-06 Time 10:35 Rev Time 0.00
Received By jgomez Date 2018-04-06 Time 10:35 Sent To  
Notes
2018-04-06 10:36:06RESIDENTIAL (R3) REVISION FOURTH MECHANICAL REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE:
 RECEIVED E-MAIL FROM JOE DARSCH FROM ASTRO AIR INC. THE
 SAME INFORMATION WAS SUBMITTED ON THE THIRD REVIEW WAS
 E-MAILED THIS TIME. NEED TO ADDRESS THE COMMENTS FROM
 THIRD REVIEW. SEE COPY OF COMMENTS BELOW AND RESUBMIT.
  
  
 RESIDENTIAL (R3) REVISION THIRD MECHANICAL REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 ORIGINAL COMMENT:
 1- BASED ON THE EQUIPMENT SIZING CALCULATIONS SUBMITTED
 IT LOOKS LIKE THE A/C EQUIPMENT MAY BE OVER-SIZED. THE
 TOTAL COOLING CALCULATIONS CALL FOR 31453 BTUH.
 THEREFORE, A 3 TON UNIT MAY BE THE CORRECT SIZE OF UNIT
 REQUIRED. THE SPECIFIED EQUIPMENT IS A 4 TON UNIT. THE
 EQUIPMENT CAN NOT BE MORE THAN 1.15 TIMES GREATER THAN
 THE TOTAL LOAD CALCULATED. SEC. R403.6.1.1 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014). EQUIPMENT NEEDS TO BE
 REVISED ACCORDINGLY.
  
 RESPONSE:
 CLARIFY WHY SUBMITTING DIFFERENT EQUIPMENT SIZING
 CALCULATIONS. PREVIOUS CALCULATIONS LOOKED TO BE OK.
 THE ONLY THING WAS THAT SELECTED EQUIPMENT WAS
 OVERSIZED. CALCULATIONS SUBMITTED NOW HAVE A TOTAL
 COOLING LOAD OF 25459 BTUH. THEREFORE, THE 36000 BTUH
 IS OVERSIZED BASED ON THIS CALCULATIONS. REVISE AS
 REQUIRED. PROVIDE COORDINATED INFORMATION.
  
 2- PERSON RESPONSIBLE FOR THE A/C PLAN TO PROVIDE NAME
 AND SIGNATURE ON THE PLAN AS REQUIRED BY SEC. 107.2.1
 CITY AMENDMENTS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2018-04-05 Cont ID  
Sent By jgomez Date 2018-04-05 Time 10:09 Rev Time 0.00
Received By jgomez Date 2018-04-05 Time 10:09 Sent To  
Notes
2018-04-05 10:16:13RESIDENTIAL (R3) REVISION THIRD MECHANICAL REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 ORIGINAL COMMENT:
 1- BASED ON THE EQUIPMENT SIZING CALCULATIONS SUBMITTED
 IT LOOKS LIKE THE A/C EQUIPMENT MAY BE OVER-SIZED. THE
 TOTAL COOLING CALCULATIONS CALL FOR 31453 BTUH.
 THEREFORE, A 3 TON UNIT MAY BE THE CORRECT SIZE OF UNIT
 REQUIRED. THE SPECIFIED EQUIPMENT IS A 4 TON UNIT. THE
 EQUIPMENT CAN NOT BE MORE THAN 1.15 TIMES GREATER THAN
 THE TOTAL LOAD CALCULATED. SEC. R403.6.1.1 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014). EQUIPMENT NEEDS TO BE
 REVISED ACCORDINGLY.
  
 RESPONSE:
 CLARIFY WHY SUBMITTING DIFFERENT EQUIPMENT SIZING
 CALCULATIONS. PREVIOUS CALCULATIONS LOOKED TO BE OK.
 THE ONLY THING WAS THAT SELECTED EQUIPMENT WAS
 OVERSIZED. CALCULATIONS SUBMITTED NOW HAVE A TOTAL
 COOLING LOAD OF 25459 BTUH. THEREFORE, THE 36000 BTUH
 IS OVERSIZED BASED ON THIS CALCULATIONS. REVISE AS
 REQUIRED. PROVIDE COORDINATED INFORMATION.
  
 2- PERSON RESPONSIBLE FOR THE A/C PLAN TO PROVIDE NAME
 AND SIGNATURE ON THE PLAN AS REQUIRED BY SEC. 107.2.1
 CITY AMENDMENTS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2018-02-27 Cont ID  
Sent By jgomez Date 2018-02-22 Time 17:07 Rev Time 0.00
Received By jgomez Date 2018-02-22 Time 17:07 Sent To  
Notes
2018-02-22 17:08:14RESIDENTIAL (R3) REVISION SECOND MECHANICAL REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- BASED ON THE EQUIPMENT SIZING CALCULATIONS SUBMITTED
 IT LOOKS LIKE THE A/C EQUIPMENT MAY BE OVER-SIZED. THE
 TOTAL COOLING CALCULATIONS CALL FOR 31453 BTUH.
 THEREFORE, A 3 TON UNIT MAY BE THE CORRECT SIZE OF UNIT
 REQUIRED. THE SPECIFIED EQUIPMENT IS A 4 TON UNIT. THE
 EQUIPMENT CAN NOT BE MORE THAN 1.15 TIMES GREATER THAN
 THE TOTAL LOAD CALCULATED. SEC. R403.6.1.1 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014). EQUIPMENT NEEDS TO BE
 REVISED ACCORDINGLY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-02-06 Cont ID  
Sent By jgomez Date 2018-02-06 Time 17:19 Rev Time 0.00
Received By jgomez Date 2018-02-06 Time 11:39 Sent To  
Notes
2018-02-06 17:19:52RESIDENTIAL (R3) REVISION MECHANICAL REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- DRAWING SUBMITTED NEED TO HAVE THE SEAL AND
 SIGNATURE OF THE ARCHITECT OF RECORD SHOWN ON THE TITLE
 BLOCK AS REQUIRED BY CHAPTER 481 FLORIDA STATUTE.
  
 2- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS BASED
 ON THE ACTUAL ORIENTATION OF THE BUILDING AS REQUIRED
 BY SEC. R403.6.1 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014). ONLY SUMMARY SHEETS WERE SUBMITTED. PROVIDE
 COMPLETE WORKSHEETS BASED ON THE ORIENTATION OF THE
 BUILDING.
  
 3- AHRI NUMBER SHOWN ON THE EQUIPMENT SIZING
 CALCULATIONS DOESN'T MATCH AHRI NUMBER SHOWN ON THE
 AHRI CERTIFICATED SUBMITTED AND SHOWN ON PLAN
 SUBMITTED. REVISE AS REQUIRED TO MATCH. SEC. 107.3.5.3
 CITY AMENDMENTS.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]