| Plan Review Stops For Permit 18011193 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2018-04-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-04-13 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-04-13 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-04-06 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-04-06 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2018-04-06 10:30:48 | RESIDENTIAL (R3) REVISION FOURTH BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | NOTE: | | | RECEIVED E-MAIL FROM JOE DARSCH FROM ASTRO AIR INC. THE | | | SAME INFORMATION WAS SUBMITTED ON THE THIRD REVIEW WAS | | | E-MAILED THIS TIME. NEED TO ADDRESS THE COMMENTS FROM | | | THIRD REVIEW. SEE COPY OF COMMENTS BELOW AND RESUBMIT. | | | | | | | | | | | | RESIDENTIAL (R3) REVISION THIRD BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED | | | AND DATED BY THE OWNER OR OWNER'S LEGALLY DESIGNATED | | | AGENT AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY | | | CONSERVATION. | | | | | | SEC. R103.1.1.2 CODE COMPLIANCE CERTIFICATION. | | | THE BUILDING'S OWNER, THE OWNER'S ARCHITECT OR OTHER | | | AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL | | | CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE | | | CODE, AS PER SECTION 553.907, FLORIDA STATUTES, PRIOR | | | TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR | | | RENOVATION. | | | | | | 2- BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | | (EPL) DISPLAY CARD. SEC. R405.4.3 FBC-RESIDENTIAL. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-04-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-04-05 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-04-05 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2018-04-05 09:15:39 | RESIDENTIAL (R3) REVISION THIRD BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED | | | AND DATED BY THE OWNER OR OWNER'S LEGALLY DESIGNATED | | | AGENT AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY | | | CONSERVATION. | | | | | | SEC. R103.1.1.2 CODE COMPLIANCE CERTIFICATION. | | | THE BUILDING'S OWNER, THE OWNER'S ARCHITECT OR OTHER | | | AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL | | | CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE | | | CODE, AS PER SECTION 553.907, FLORIDA STATUTES, PRIOR | | | TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR | | | RENOVATION. | | | | | | 2- BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | | (EPL) DISPLAY CARD. SEC. R405.4.3 FBC-RESIDENTIAL. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-02-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-02-22 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-02-22 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2018-02-22 15:11:32 | RESIDENTIAL (R3) REVISION SECOND BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- ENERGY CALCULATIONS NEED TO BE REVISED BECAUSE THE | | | A/C EQUIPMENT IS OVERSIZED. SEE MECHANICAL COMMENTS | | | REGARDING THE A/C EQUIPMENT SIZING. SEC. R403.6.1.1 | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-02-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-02-06 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-02-06 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2018-02-06 12:41:27 | RESIDENTIAL (R3) REVISION BUILDING REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- REVISION DESCRIPTION INDICATES THAT REVISED ENERGY | | | CALCULATIONS WERE SUBMITTED. THERE ARE NO ENERGY | | | CALCULATIONS IN THIS SUBMITTAL. PROVIDE COMPLETE AND | | | CORRECT REVISED ENERGY CALCULATIONS AS REQUESTED ON | | | PROVISO DATED 12/19/17. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2018-04-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-04-13 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-04-13 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2018-04-13 10:16:32 | MET WITH STEVE FROM ASTRO AIR AND KEVIN FROM BALDWIN | | | INNOVATIVE BUILDERS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-04-06 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-04-06 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2018-04-06 10:30:28 | RECEIVED E-MAIL FROM JOE DARSCH FROM ASTRO AIR INC. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-04-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-04-05 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-04-05 |
Time |
08:56 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-02-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-02-22 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-02-20 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2018-02-21 10:05:55 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-02-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-02-06 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-01-30 |
Time |
10:43 |
Sent To |
I |
|
| Notes |
| 2018-01-31 10:44:14 | REVISION ROUTED TO JGOMEZ |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2018-04-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-04-13 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-04-13 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2018-04-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-04-06 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-04-06 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2018-04-06 10:36:06 | RESIDENTIAL (R3) REVISION FOURTH MECHANICAL REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | NOTE: | | | RECEIVED E-MAIL FROM JOE DARSCH FROM ASTRO AIR INC. THE | | | SAME INFORMATION WAS SUBMITTED ON THE THIRD REVIEW WAS | | | E-MAILED THIS TIME. NEED TO ADDRESS THE COMMENTS FROM | | | THIRD REVIEW. SEE COPY OF COMMENTS BELOW AND RESUBMIT. | | | | | | | | | RESIDENTIAL (R3) REVISION THIRD MECHANICAL REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | ORIGINAL COMMENT: | | | 1- BASED ON THE EQUIPMENT SIZING CALCULATIONS SUBMITTED | | | IT LOOKS LIKE THE A/C EQUIPMENT MAY BE OVER-SIZED. THE | | | TOTAL COOLING CALCULATIONS CALL FOR 31453 BTUH. | | | THEREFORE, A 3 TON UNIT MAY BE THE CORRECT SIZE OF UNIT | | | REQUIRED. THE SPECIFIED EQUIPMENT IS A 4 TON UNIT. THE | | | EQUIPMENT CAN NOT BE MORE THAN 1.15 TIMES GREATER THAN | | | THE TOTAL LOAD CALCULATED. SEC. R403.6.1.1 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). EQUIPMENT NEEDS TO BE | | | REVISED ACCORDINGLY. | | | | | | RESPONSE: | | | CLARIFY WHY SUBMITTING DIFFERENT EQUIPMENT SIZING | | | CALCULATIONS. PREVIOUS CALCULATIONS LOOKED TO BE OK. | | | THE ONLY THING WAS THAT SELECTED EQUIPMENT WAS | | | OVERSIZED. CALCULATIONS SUBMITTED NOW HAVE A TOTAL | | | COOLING LOAD OF 25459 BTUH. THEREFORE, THE 36000 BTUH | | | IS OVERSIZED BASED ON THIS CALCULATIONS. REVISE AS | | | REQUIRED. PROVIDE COORDINATED INFORMATION. | | | | | | 2- PERSON RESPONSIBLE FOR THE A/C PLAN TO PROVIDE NAME | | | AND SIGNATURE ON THE PLAN AS REQUIRED BY SEC. 107.2.1 | | | CITY AMENDMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2018-04-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-04-05 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-04-05 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2018-04-05 10:16:13 | RESIDENTIAL (R3) REVISION THIRD MECHANICAL REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | ORIGINAL COMMENT: | | | 1- BASED ON THE EQUIPMENT SIZING CALCULATIONS SUBMITTED | | | IT LOOKS LIKE THE A/C EQUIPMENT MAY BE OVER-SIZED. THE | | | TOTAL COOLING CALCULATIONS CALL FOR 31453 BTUH. | | | THEREFORE, A 3 TON UNIT MAY BE THE CORRECT SIZE OF UNIT | | | REQUIRED. THE SPECIFIED EQUIPMENT IS A 4 TON UNIT. THE | | | EQUIPMENT CAN NOT BE MORE THAN 1.15 TIMES GREATER THAN | | | THE TOTAL LOAD CALCULATED. SEC. R403.6.1.1 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). EQUIPMENT NEEDS TO BE | | | REVISED ACCORDINGLY. | | | | | | RESPONSE: | | | CLARIFY WHY SUBMITTING DIFFERENT EQUIPMENT SIZING | | | CALCULATIONS. PREVIOUS CALCULATIONS LOOKED TO BE OK. | | | THE ONLY THING WAS THAT SELECTED EQUIPMENT WAS | | | OVERSIZED. CALCULATIONS SUBMITTED NOW HAVE A TOTAL | | | COOLING LOAD OF 25459 BTUH. THEREFORE, THE 36000 BTUH | | | IS OVERSIZED BASED ON THIS CALCULATIONS. REVISE AS | | | REQUIRED. PROVIDE COORDINATED INFORMATION. | | | | | | 2- PERSON RESPONSIBLE FOR THE A/C PLAN TO PROVIDE NAME | | | AND SIGNATURE ON THE PLAN AS REQUIRED BY SEC. 107.2.1 | | | CITY AMENDMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-02-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-02-22 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-02-22 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2018-02-22 17:08:14 | RESIDENTIAL (R3) REVISION SECOND MECHANICAL REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- BASED ON THE EQUIPMENT SIZING CALCULATIONS SUBMITTED | | | IT LOOKS LIKE THE A/C EQUIPMENT MAY BE OVER-SIZED. THE | | | TOTAL COOLING CALCULATIONS CALL FOR 31453 BTUH. | | | THEREFORE, A 3 TON UNIT MAY BE THE CORRECT SIZE OF UNIT | | | REQUIRED. THE SPECIFIED EQUIPMENT IS A 4 TON UNIT. THE | | | EQUIPMENT CAN NOT BE MORE THAN 1.15 TIMES GREATER THAN | | | THE TOTAL LOAD CALCULATED. SEC. R403.6.1.1 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). EQUIPMENT NEEDS TO BE | | | REVISED ACCORDINGLY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-02-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-02-06 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-02-06 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2018-02-06 17:19:52 | RESIDENTIAL (R3) REVISION MECHANICAL REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- DRAWING SUBMITTED NEED TO HAVE THE SEAL AND | | | SIGNATURE OF THE ARCHITECT OF RECORD SHOWN ON THE TITLE | | | BLOCK AS REQUIRED BY CHAPTER 481 FLORIDA STATUTE. | | | | | | 2- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS BASED | | | ON THE ACTUAL ORIENTATION OF THE BUILDING AS REQUIRED | | | BY SEC. R403.6.1 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). ONLY SUMMARY SHEETS WERE SUBMITTED. PROVIDE | | | COMPLETE WORKSHEETS BASED ON THE ORIENTATION OF THE | | | BUILDING. | | | | | | 3- AHRI NUMBER SHOWN ON THE EQUIPMENT SIZING | | | CALCULATIONS DOESN'T MATCH AHRI NUMBER SHOWN ON THE | | | AHRI CERTIFICATED SUBMITTED AND SHOWN ON PLAN | | | SUBMITTED. REVISE AS REQUIRED TO MATCH. SEC. 107.3.5.3 | | | CITY AMENDMENTS. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|