Plan Review Details - Permit 18011120
Plan Review Stops For Permit 18011120
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2018-02-12 Cont ID  
Sent By lcrespo Date 2018-02-12 Time 13:47 Rev Time 0.00
Received By lcrespo Date 2018-02-12 Time 13:47 Sent To  
Notes
2018-02-12 13:48:422/12/18 APPROVED BY PLUMBING AND SENT TO PROCESSING,
 LAC

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2018-02-02 Cont ID  
Sent By tklarge Date 2018-02-02 Time 06:35 Rev Time 0.00
Received By tklarge Date 2018-02-02 Time 04:54 Sent To I
Notes
2018-02-02 06:35:021) SUBMIT MANUFACTURING SPECIFICATIONS FOR THE
 GENERATOR.WPB AMEND. TO FBC SEC. 107.2.1.
 2) THE UNDERGROUND TANK IS SHOWN IN THE MIDDLE OF
 DRIVEWAY ON THE SURVEY. INDICATE HOW THE LP TANK IS
 GOING TO BE PROTECTED FROM DAMAGE. PROTECTION SHALL BE
 PROVIDED IN ACCCORDANCE WITH 2014 NFPA 58 SEC.6.6.6.1
 (E).
 NFPA 58 - 6.6.6.1* ASME CONTAINER ASSEMBLIES INTENDED
 FOR UNDERGROUND INSTALLATION, INCLUDING INTERCHANGEABLE
 ABOVEGROUND ? UNDERGROUND CONTAINER ASSEMBLIES, SHALL
 BE INSTALLED UNDERGROUND IN ACCORDANCE WITH 6.6.6.1(A)
 THROUGH 6.6.6.1(M).
 (E) THE INSTALLATION OF A BURIED CONTAINER SHALL
 INCLUDE PROTECTION
 FOR THE CONTAINER AND PIPING AGAINST PHYSICAL DAMAGE
 FROM VEHICULAR TRAFFIC.
 3) INDICATE HOW THE FIRST STAGE REGULATOR IS GOING TO
 BE VENTED WHEN THE TANK IS IN THE MIDDLE OF THE
 DRIVEWAY.THE VENT SHALL COMPLY WITH NFPA 58 SEC.
 6.6.6.1 ( H) - THE DISCHARGE OF THE REGULATOR VENT
 SHALL BE ABOVE THE
 HIGHEST PROBABLE WATER LEVEL.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-02-12 Cont ID  
Sent By lcrespo Date 2018-02-12 Time 13:47 Rev Time 0.00
Received By lcrespo Date 2018-02-07 Time 10:15 Sent To  
Notes
2018-02-08 10:16:09RESUB RUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-02-02 Cont ID  
Sent By tklarge Date 2018-02-02 Time 06:35 Rev Time 0.00
Received By tklarge Date 2018-01-29 Time 11:24 Sent To  
Notes
2018-01-30 11:24:36ROUTED TO PLUMBING INBOX