Plan Review Details - Permit 18011081
| Plan Review Stops For Permit 18011081 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-02-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-02-20 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-02-20 |
Time |
06:24 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-02-14 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-02-14 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-02-14 |
Time |
07:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-02-01 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-02-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-02-01 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-03-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-02-22 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2018-02-22 15:21:23 | RESUB OF REVISION ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-02-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-02-20 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-01-26 |
Time |
13:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-03-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-03-06 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-03-06 |
Time |
07:13 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-02-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-02-12 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-02-09 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2018-02-12 09:32:21 | 1ST REVIEW FBC-2014 MECHANICAL | | | REVISION #18011081 | | | MASTER #16090832 | | | 2/12/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M-222: MISSING FIRE DAMPERS FOR DUCTS | | | PENETRATING THE FIRE-RATED MECHANICAL ROOM/FUTURE | | | EXPANSION AREA WALL- SECTION 607.5.2. | | | | | | 2) SUBMIT TWO COPIES OF THE O/A LOUVER PRODUICT | | | APPROVAL OR NOA WITH APPROVAL STAMP BY THE EOR. | | | | | | 3) INDICATE COMPLIANCE WITH SECTION C403.2.4.4 FBC-14 | | | ENERGY CONSERVATION FOR REQUIRED AUTOMATIC CONTROL OF | | | THE OUTSIDE AIRFLOW TO THE AIR HANDLER. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
|