Plan Review Details - Permit 18010931
| Plan Review Stops For Permit 18010931 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-02-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-02-02 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-02-02 |
Time |
13:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-02-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-02-02 |
Time |
07:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-02-02 |
Time |
06:18 |
Sent To |
I |
|
| Notes |
| 2018-02-02 07:14:39 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) (REPEAT COMMENT) SPECIFY WHICH ONE OF THE APPROVED | | | SYSTEMS LISTED IN THE PRODUCT APPROVAL FOR THE | | | CERTAINTEED COVENTIONAL BUILT UP ROOF SYSTEM WILL BE | | | USED. SUBMIT TWO SETS OF RAS 117 CALCULATIONS FOR | | | ENHANCED FASTENING AS REQUIRED BY LIMITATION NUMBER 7 | | | ON PAGE 16 NOA NO. 13-0204.14. | | | THE SYSTEM THAT YOU SELECTED ON PAGE 13 OF THE PRODUCT | | | APPROVAL HAS A MAXIMUM DESIGN PRESSURE OF -45PSF AND | | | CAN NOT BE ENHANCED TO MEET THE INCREASED PRESSURES AT | | | THE PERIMETER AND CORNER AREAS OF THE ROOF PER | | | LIMITATION #9. SELECT A SYSTEM WHICH ALLOWS ENHANCED | | | FASTENING (LIMITATION #7) AND SUBMIT SIGNED AND SEALED | | | RAS 117 CALCULATIONS IN ACCORDANCE WITH GENERAL | | | LIMITATION #7 ON THE LAST PAGE OF THE PRODUCT APPROVAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-01-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-01-26 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-01-26 |
Time |
17:06 |
Sent To |
I |
|
| Notes |
| 2018-01-26 18:56:21 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SPECIFY WHICH ONE OF THE APPROVED SYSTEMS LISTED IN | | | THE PRODUCT APPROVAL FOR THE CERTAINTEED COVENTIONAL | | | BUILT UP ROOF SYSTEM WILL BE USED. SUBMIT TWO SETS OF | | | RAS 117 CALCULATIONS FOR ENHANCED FASTENING AS REQUIRED | | | BY LIMITATION NUMBER 7 ON PAGE 16 NOA NO. 13-0204.14. | | | | | | 2) YOU INDICATED THAT THE SLOPED ROOF HAS A 3:12 SLOPE. | | | FBC-R905.2.2 REQUIRES DOUBLE UNDERLAYMENT INSTALLED IN | | | ACCORDANCE WITH FBC-R905.1.1 FOR ASPHALT SHINGLE ROOFS | | | WITH SLOPES LESS THAN 4:12. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-01-25 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2018-01-25 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2018-01-25 |
Time |
11:26 |
Sent To |
B |
|
| Notes |
| 2018-01-25 16:23:54 | 1/25/2018 - RE-ROOF IN KIND (SHINGLE TO SHINGLE, FLAT | | | TO FLAT) MEETS DESIGN GUIDELINES OF HISTORIC DISTRICT. | | | DLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-02-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-02-02 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-02-02 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2018-02-02 13:35:25 | CONTRACTOR BROUGHT IN NEW PRODUCT APPROVALS FOR THE | | | FLAT ROOF. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-02-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-02-02 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-01-31 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2018-02-01 13:35:56 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-01-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-01-26 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-01-24 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2018-01-24 16:14:10 | ROUTED TO HISTORIC VIA ZONING INBOX |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |