| Plan Review Stops For Permit 18010849 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-01-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-01-04 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-01-04 |
Time |
13:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-02-22 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-02-22 |
Time |
06:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-01-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-01-29 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-01-29 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2018-01-29 08:46:18 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 18010849 | | | ADD: 2331 NORTHWOOD UNIVERSITY DR. | | | CONT: CHINOOK CONSTRUCTION | | | TEL: 954-776-6700 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. JAN. 29/ 2018 | | | ACTION: DENIED. | | | | | | 1) 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 102.2 BUILDING ( E ). THE FOLLOWING | | | BUILDINGS, STRUCTURES AND FACILITIES ARE EXEMPT FROM | | | THE FLORIDA BUILDING CODE AS PROVIDED BY LAW, AND ANY | | | FURTHER EXEMPTIONS SHALL BE AS DETERMINED BY THE | | | LEGISLATURE AND PROVIDED BY LAW: | | | (E) MOBILE OR MODULAR STRUCTURES USED AS TEMPORARY | | | OFFICES, EXCEPT THAT THE PROVISIONS OF PART V | | | (SECTION 553.501-553.513, FLORIDA STATUTES) RELATING TO | | | ACCESSIBILITY BY PERSONS WITH DISABILITIES, | | | AND PERMITS SHALL BE REQUIRED FOR STRUCTURAL SUPPORT | | | AND TIE DOWN, ELECTRICAL SUPPLY, AND ALL UTILITY | | | CONNECTIONS TO SUCH MOBILE OR MODULAR STRUCTURES. | | | | | | PLEASE PROVIDE A LETTER ON THE CONTRACTORS? LETTERHEAD | | | STATING IF THIS CONSTRUCTION TRAILER WILL BE USED FOR | | | MEETINGS WITH OFFSITE PERSONS, ARCHITECT, ENGINEER OR | | | VENDORS, IF SO THEN PLANS FOR ACCESSIBLE PARKING, | | | ACCESS AISLE, RAMPS, HANDRAILS, GUARDRAILS AND LANDINGS | | | WILL BE REQUIRED. | | | | | | 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-03-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-03-05 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-03-05 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-02-08 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-02-08 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-02-08 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2018-02-08 15:36:44 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDED RISER DIAGRAM THAT WAS ATTACHED TO THE PLAN | | | WAS NOT SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR | | | THE DESIGN. PROVIDE CORRECTION. FBC 107.2.1; FS | | | 471.003, 471.25 | | | 2. PROVIDE CORRECT CODE REFERENCES PER CURRENT ADOPTED | | | CODES. SEE ABOVE FOR CURRENT CODES. FBC 107.2.1 | | | 3. PROVIDE WEATHER PROOF GFCI RECEPTACLE AT SERVICE. | | | NEC 210.64 | | | 4. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 5. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | 6. PROVIDE AIC RATING OF SERVICE EQUIPMENT AND PANELS. | | | NEC 110.3, 110.9 | | | 7. RISER DIAGRAM SHOWS A 60 AMP CIRCUIT ON # 6 WIRE | | | FEEDING THE TRAILER. SHEET A1 STATES THAT THE FEED TO | | | THE PANEL IS REQUIRED TO BE AT LEAST 100 AMPS. SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. PROVIDE | | | CORRECTIONS. NEC 215.5, 230, 250.50, 250.94, 408.30; | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-01-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-01-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-01-29 |
Time |
11:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-01-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-01-04 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-11-29 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2018-11-30 15:18:45 | RESUB ROUTED ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-03-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-12 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-16 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-02-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-12 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-23 |
Time |
15:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2018-02-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-02-28 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-02-28 |
Time |
14:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-02-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-02-06 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-02-06 |
Time |
17:50 |
Sent To |
|
|
| Notes |
| 2018-02-06 17:52:32 | 1ST REVIEW FBC-2017 MECHANICAL, ENERGY CONSERVATION | | | CODES | | | PERMIT #18010849 | | | 2/6/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET C1: THE PLANS HAVE BEEN DESIGNED IN ACCORDANCE | | | WITH THE FBC SIXTH EDITION 2017. PLEASE SUBMIT AN | | | UPDATED ENERGY COMPLIANCE FORM- SEE SECTIONS C101.5 AND | | | C101.5.1 FBC-17 ENERGY CONSERVATION. | | | | | | 2) SUBMIT AC COOLING AND HEATING CALCULATIONS IN | | | ACCORDANCE WITH SECTION C403.2.1. | | | | | | 3) PROVIDE MINIMUM VENTILATION CALCULATIONS IN | | | ACCORDANCE WITH TABLE 403.3. | | | | | | 4) PROVIDE A DUCT LAYOUT DRAWING. CLARIFY HOW SUPPLY | | | AIR WILL BE EVENLY DISTRIBUTED THROUGHOUT THE OFFICE | | | SPACE AND RETUNED TO THE AIR HANDLER. | | | | | | 5) PROVIDE WIND LOAD ENGINEERING FOR INSTALLATION OF | | | THE BARD UNITS ON THE EXTERIOR WALL- SECTION 301.15 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2018-03-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-12 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-12 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2018-03-12 16:01:25 | NO PLUMBING PER CONTRACTORS LETTER. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-02-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-12 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-12 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2018-02-12 15:57:50 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE A SITE PLAN SHOWING SEWER AND WATER | | | CONNECTIONS . PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. A BACKFLOW IS REQUIRED. PER FBC PL 608.1 | | | | | | 3. A SEPARATE PERMIT I REQUIRED FOR BACK FLOW. PER WPB | | | UTILITIES DEPT. PLACE NOTE ON PLAN | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-12-31 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-12-31 |
Time |
11:02 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-12-31 |
Time |
11:02 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-02-22 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-02-22 |
Time |
15:34 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-02-22 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2018-02-22 15:35:09 | FAILED | | | | | | THE CONSTRUCTION TRAILER MAY NOT BE LOCATED ADJACENT TO | | | THE SEMINOLE COLONY RESIDENTIAL HOMES. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-02-05 |
|
|
Cont ID |
|
| Sent By |
ES |
Date |
2018-02-05 |
Time |
13:46 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-02-05 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2018-02-05 13:52:22 | FAILED | | | | | | THE CONSTRUCTION TRAILER MAY NOT BE LOCATED ADJACENT TO | | | THE SEMINOLE COLONY RESIDENTIAL HOMES. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | [email protected] |
|
|