Plan Review Details - Permit 18010849
Plan Review Stops For Permit 18010849
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-01-04 Cont ID  
Sent By pvalenti Date 2019-01-04 Time 13:41 Rev Time 0.00
Received By pvalenti Date 2019-01-04 Time 13:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2018-02-22 Time 07:29 Rev Time 0.00
Received By jwitmer Date 2018-02-22 Time 06:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-01-29 Cont ID  
Sent By jwitmer Date 2018-01-29 Time 08:59 Rev Time 0.00
Received By jwitmer Date 2018-01-29 Time 08:31 Sent To  
Notes
2018-01-29 08:46:182014 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 18010849
 ADD: 2331 NORTHWOOD UNIVERSITY DR.
 CONT: CHINOOK CONSTRUCTION
 TEL: 954-776-6700
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JAN. 29/ 2018
 ACTION: DENIED.
  
 1) 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION 102.2 BUILDING ( E ). THE FOLLOWING
 BUILDINGS, STRUCTURES AND FACILITIES ARE EXEMPT FROM
 THE FLORIDA BUILDING CODE AS PROVIDED BY LAW, AND ANY
 FURTHER EXEMPTIONS SHALL BE AS DETERMINED BY THE
 LEGISLATURE AND PROVIDED BY LAW:
 (E) MOBILE OR MODULAR STRUCTURES USED AS TEMPORARY
 OFFICES, EXCEPT THAT THE PROVISIONS OF PART V
 (SECTION 553.501-553.513, FLORIDA STATUTES) RELATING TO
 ACCESSIBILITY BY PERSONS WITH DISABILITIES,
 AND PERMITS SHALL BE REQUIRED FOR STRUCTURAL SUPPORT
 AND TIE DOWN, ELECTRICAL SUPPLY, AND ALL UTILITY
 CONNECTIONS TO SUCH MOBILE OR MODULAR STRUCTURES.
  
 PLEASE PROVIDE A LETTER ON THE CONTRACTORS? LETTERHEAD
 STATING IF THIS CONSTRUCTION TRAILER WILL BE USED FOR
 MEETINGS WITH OFFSITE PERSONS, ARCHITECT, ENGINEER OR
 VENDORS, IF SO THEN PLANS FOR ACCESSIBLE PARKING,
 ACCESS AISLE, RAMPS, HANDRAILS, GUARDRAILS AND LANDINGS
 WILL BE REQUIRED.
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-03-05 Cont ID  
Sent By jpearson Date 2018-03-05 Time 16:00 Rev Time 0.00
Received By jpearson Date 2018-03-05 Time 16:00 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-02-08 Cont ID  
Sent By jpearson Date 2018-02-08 Time 15:36 Rev Time 0.00
Received By jpearson Date 2018-02-08 Time 11:06 Sent To  
Notes
2018-02-08 15:36:44CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDED RISER DIAGRAM THAT WAS ATTACHED TO THE PLAN
 WAS NOT SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR
 THE DESIGN. PROVIDE CORRECTION. FBC 107.2.1; FS
 471.003, 471.25
 2. PROVIDE CORRECT CODE REFERENCES PER CURRENT ADOPTED
 CODES. SEE ABOVE FOR CURRENT CODES. FBC 107.2.1
 3. PROVIDE WEATHER PROOF GFCI RECEPTACLE AT SERVICE.
 NEC 210.64
 4. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE.
 NEC 110.9, 110.10
 5. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF
 SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND
 AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24
 6. PROVIDE AIC RATING OF SERVICE EQUIPMENT AND PANELS.
 NEC 110.3, 110.9
 7. RISER DIAGRAM SHOWS A 60 AMP CIRCUIT ON # 6 WIRE
 FEEDING THE TRAILER. SHEET A1 STATES THAT THE FEED TO
 THE PANEL IS REQUIRED TO BE AT LEAST 100 AMPS. SHOW
 INTERSYSTEM BONDING TERMINATION POINT. PROVIDE
 CORRECTIONS. NEC 215.5, 230, 250.50, 250.94, 408.30;
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-01-29 Cont ID  
Sent By pleduc Date 2018-01-29 Time   Rev Time 0.00
Received By pleduc Date 2018-01-29 Time 11:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-01-04 Cont ID  
Sent By pvalenti Date 2019-01-04 Time 13:41 Rev Time 0.00
Received By pvalenti Date 2018-11-29 Time 15:18 Sent To  
Notes
2018-11-30 15:18:45RESUB ROUTED ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-03-12 Cont ID  
Sent By gjohnson Date 2018-03-12 Time 16:01 Rev Time 0.00
Received By gjohnson Date 2018-02-16 Time 15:33 Sent To  
Notes
2018-02-20 15:33:45B12

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-02-12 Cont ID  
Sent By gjohnson Date 2018-02-12 Time 15:58 Rev Time 0.00
Received By gjohnson Date 2018-01-23 Time 15:01 Sent To  
Notes
2018-01-25 15:00:53B06

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2018-02-28 Cont ID  
Sent By ccole Date 2018-02-28 Time 14:46 Rev Time 0.00
Received By ccole Date 2018-02-28 Time 14:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-02-06 Cont ID  
Sent By ccole Date 2018-02-06 Time 17:50 Rev Time 0.00
Received By ccole Date 2018-02-06 Time 17:50 Sent To  
Notes
2018-02-06 17:52:321ST REVIEW FBC-2017 MECHANICAL, ENERGY CONSERVATION
 CODES
 PERMIT #18010849
 2/6/18
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET C1: THE PLANS HAVE BEEN DESIGNED IN ACCORDANCE
 WITH THE FBC SIXTH EDITION 2017. PLEASE SUBMIT AN
 UPDATED ENERGY COMPLIANCE FORM- SEE SECTIONS C101.5 AND
 C101.5.1 FBC-17 ENERGY CONSERVATION.
  
 2) SUBMIT AC COOLING AND HEATING CALCULATIONS IN
 ACCORDANCE WITH SECTION C403.2.1.
  
 3) PROVIDE MINIMUM VENTILATION CALCULATIONS IN
 ACCORDANCE WITH TABLE 403.3.
  
 4) PROVIDE A DUCT LAYOUT DRAWING. CLARIFY HOW SUPPLY
 AIR WILL BE EVENLY DISTRIBUTED THROUGHOUT THE OFFICE
 SPACE AND RETUNED TO THE AIR HANDLER.
  
 5) PROVIDE WIND LOAD ENGINEERING FOR INSTALLATION OF
 THE BARD UNITS ON THE EXTERIOR WALL- SECTION 301.15
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status N Date 2018-03-12 Cont ID  
Sent By gjohnson Date 2018-03-12 Time 16:01 Rev Time 0.00
Received By gjohnson Date 2018-03-12 Time 16:00 Sent To  
Notes
2018-03-12 16:01:25NO PLUMBING PER CONTRACTORS LETTER.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-02-12 Cont ID  
Sent By gjohnson Date 2018-02-12 Time 15:51 Rev Time 0.00
Received By gjohnson Date 2018-02-12 Time 15:18 Sent To  
Notes
2018-02-12 15:57:501ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. PROVIDE A SITE PLAN SHOWING SEWER AND WATER
 CONNECTIONS . PER WPB AMEND TO FBC 107.2.1
  
 2. A BACKFLOW IS REQUIRED. PER FBC PL 608.1
  
 3. A SEPARATE PERMIT I REQUIRED FOR BACK FLOW. PER WPB
 UTILITIES DEPT. PLACE NOTE ON PLAN
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date 2018-12-31 Cont ID  
Sent By eschneid Date 2018-12-31 Time 11:02 Rev Time 0.25
Received By eschneid Date 2018-12-31 Time 11:02 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2018-02-22 Cont ID  
Sent By eschneid Date 2018-02-22 Time 15:34 Rev Time 0.25
Received By eschneid Date 2018-02-22 Time 15:33 Sent To  
Notes
2018-02-22 15:35:09FAILED
  
 THE CONSTRUCTION TRAILER MAY NOT BE LOCATED ADJACENT TO
 THE SEMINOLE COLONY RESIDENTIAL HOMES.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2018-02-05 Cont ID  
Sent By ES Date 2018-02-05 Time 13:46 Rev Time 0.25
Received By eschneid Date 2018-02-05 Time 11:53 Sent To  
Notes
2018-02-05 13:52:22FAILED
  
 THE CONSTRUCTION TRAILER MAY NOT BE LOCATED ADJACENT TO
 THE SEMINOLE COLONY RESIDENTIAL HOMES.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
 [email protected]