Plan Review Details - Permit 18010815
| Plan Review Stops For Permit 18010815 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-02-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-02-16 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-02-16 |
Time |
06:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-01-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-01-29 |
Time |
06:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-01-26 |
Time |
17:27 |
Sent To |
|
|
| Notes |
| 2018-01-29 06:58:19 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 18010815 | | | ADD: 2806 GIN BERRY WAY | | | CONT: SOBEL CO. | | | TEL: 954-410-9239 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. JAN. 29/ 2018 | | | ACTION: DENIED | | | | | | 1) THIS PLAN DOES NOT HAVE A STATE APPROVAL. SHEET C1 | | | AS BUILT NOTES REFERS TO THESE APPROVED PLANS ARE NO | | | LONGER AVAILABLE AND REFERS TO RULE 9B-1 WHICH IS | | | TRANSFERRED TO RULE 61G20-5.006. WHEN YOU GO BACK IN | | | THE ADMINISTRATIVE CODE TO VIEW THIS RULE IT REFERS YOU | | | BACK TO RULE 9B-1. PLEASE PROVIDE THE RULE AND LANGUAGE | | | OF THE RULE. OTHERWISE THE SUBMITTED PLANS WILL BE | | | VIEWED TO THE REQUIREMENTS OF : | | | | | | 102.2 ( E ) MOBILE OR MODULAR STRUCTURES USED AS | | | TEMPORARY OFFICES, EXCEPT THAT THE PROVISIONS OF PART V | | | (SECTION 553.501-553.513, FLORIDA STATUTES) RELATING TO | | | ACCESSIBILITY BY PERSONS WITH DISABILITIES, | | | AND PERMITS SHALL BE REQUIRED FOR STRUCTURAL SUPPORT | | | AND TIE DOWN, ELECTRICAL SUPPLY, AND | | | ALL UTILITY CONNECTIONS TO SUCH MOBILE OR MODULAR | | | STRUCTURES. | | | | | | THIS PERMIT APPLICATION IS FOR A TEMPORARY CONSTRUCTION | | | TRAILER, PLANS SUBMITTED AFTER DEC. 31/2017 AND NEEDS | | | TO BE DESIGNED TO THE 6TH EDITION OR THE 2017 FLORIDA | | | BUILDING CODE. STATEWIDE ADOPTION DATE. PLEASE UPDATE | | | THE PLANS TO THE CURRENT CODE EDITION. | | | | | | 2) SHEET A4 NEEDS TO BE UPDATED TO THE CURRENT CODE THE | | | 2017 FBC-B . THE WIND DESIGN HAS STAYED THE SAME, ASCE | | | 7-10. | | | | | | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2018-02-23 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-02-23 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-02-22 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2018-02-23 13:41:55 | CHANGED STATUS TO NOT REQUIRED ON 2-23-18. CONTRACTOR | | | WILL APPLY SEPARATELY FOR ELECTRICAL PERMIT. THEREFORE, | | | NO ELECTRICAL IS REVIEWED OR APPROVED ON THIS PERMIT | | | NUMBER. | | 2018-02-22 14:31:30 | PREVIOUS COMMENTS NOT ADDRESSED, SEE BELOW. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30 | | | 2. PROVIDE CORRECT CODE REFERENCES PER CURRENT ADOPTED | | | CODES. SEE ABOVE FOR CURRENT CODES. FBC 107.2.1 | | | 3. PROVIDE WEATHER PROOF GFCI RECEPTACLE AT SERVICE. | | | NEC 210.64 | | | 4. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 5. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | 6. PROVIDE AIC RATING OF SERVICE EQUIPMENT AND PANELS. | | | NEC 110.3, 110.9 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-02-08 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-02-08 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-02-08 |
Time |
06:45 |
Sent To |
|
|
| Notes |
| 2018-02-08 11:00:05 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30 | | | 2. PROVIDE CORRECT CODE REFERENCES PER CURRENT ADOPTED | | | CODES. SEE ABOVE FOR CURRENT CODES. FBC 107.2.1 | | | 3. PROVIDE WEATHER PROOF GFCI RECEPTACLE AT SERVICE. | | | NEC 210.64 | | | 4. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 5. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | 6. PROVIDE AIC RATING OF SERVICE EQUIPMENT AND PANELS. | | | NEC 110.3, 110.9 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-02-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-02-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-02-13 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-01-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-01-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-01-24 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2018-01-24 15:15:07 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) A SITE PLAN IS REQUIRED INDICATED WHERE THE PROPOSED | | | TRAILER WILL BE LOCATED. INCLUDE ALL DIMENSION TO THE | | | NEAREST BUILDINGS, OTHER TRAILERS, PROPERTY LINES AND | | | PROPOSED NEW BUILDINGS. | | | | | | PER NFPA 241, 4.2 TEMPORARY OFFICES AND SHEDS; TABLE | | | 4.2.1 SEPARATION DISTANCES, FIRE SPRINKLERS ARE | | | REQUIRED IN EACH TRAILER. | | | 4.2.1* SEPARATION DISTANCES BETWEEN BUILDINGS UNDER | | | CONSTRUCTION AND CONSTRUCTION-RELATED STRUCTURES, SUCH | | | AS TEMPORARY OFFICES, TRAILERS, SHEDS, AND OTHER | | | FACILITIES FOR THE STORAGE OF TOOLS AND MATERIALS | | | HAVING COMBUSTIBLE CONSTRUCTION OR CONTENTS, SHALL BE | | | IN ACCORDANCE WITH TABLE 4.2.1. | | | | | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | | | | NOTES: | | | (1) WHERE THE SEPARATION DISTANCE BETWEEN TEMPORARY | | | STRUCTURES IS LESS THAN THE MINIMUM SEPARATION | | | DISTANCE, THEN THE EXPOSING WALL LENGTH SHALL BE | | | CONSIDERED TO BE THE SUM OF THE INDIVIDUAL EXPOSING | | | WALL LENGTHS OF THE TEMPORARY STRUCTURES. | | | (2) A 75 PERCENT REDUCTION IN SEPARATION DISTANCES | | | SHALL BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | (3) THE SEPARATION DISTANCES APPLY TO SINGLE-LEVEL | | | STRUCTURES ONLY. THIS TABLE DOES NOT APPLY TO | | | MULTILEVEL, UNSPRINKLERED STRUCTURES. A LEVEL, WHERE | | | APPLYING THIS TABLE, IS 3600 MM (144 IN.). | | | | | | 4.2.2* DETACHMENT BETWEEN TEMPORARY STRUCTURES, | | | ADEQUATE TEMPORARY FIXED FIRE PROTECTION SYSTEMS, AND | | | PORTABLE EQUIPMENT SHALL BE PROVIDED AS REQUIRED BY THE | | | AUTHORITY HAVING JURISDICTION. | | | | | | | | | | | | | | | 3) WILL THIS TRAILER BE USED BY THE GENERAL PUBLIC? | | | WILL IT HAVE BUILT STAIRS/RALINGS, DECKING, RAMPS? | | | | | | PLEASE PROVIDE DETAILS AND/OR DRAWINGS. | | | | | | | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-03-02 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-03-02 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-02-09 |
Time |
15:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-02-09 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2018-02-09 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-01-22 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2018-02-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-02-20 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-02-20 |
Time |
09:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-02-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-02-06 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-02-06 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2018-02-06 17:44:18 | 1ST REVIEW FBC-2017 MECHANICAL, ENERGY CONSERVATION | | | CODES | | | PERMIT #18010815 | | | 2/6/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET C1: PLEASE UPDATE ALL APPLICABLE CODES TO THE | | | FBC SIXTH EDITION 2017, AND SUBMIT AN UPDATED ENERGY | | | COMPLIANCE FORM IN ACCORDANCE WITH SECTIONS C101.5 AND | | | C101.5.1 FBC-17 ENERGY CONSERVATION. | | | | | | 2) SUBMIT AC COOLING AND HEATING CALCULATIONS IN | | | ACCORDANCE WITH SECTION C403.2.1. | | | | | | 3) PROVIDE MINIMUM VENTILATION CALCULATIONS IN | | | ACCORDANCE WITH TABLE 403.3. | | | | | | 4) PROVIDE A DUCT LAYOUT DRAWING. CLARIFY HOW SUPPLY | | | AIR WILL BE EVENLY DISTRIBUTED THROUGHOUT THE OFFICE | | | SPACE AND RETUNED TO THE AIR HANDLER. | | | | | | 5) PROVIDE WIND LOAD ENGINEERING FOR INSTALLATION OF | | | THE BARD UNITS ON THE EXTERIOR WALL- SECTION 301.15 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-02-27 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-02-27 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-02-27 |
Time |
06:57 |
Sent To |
|
|
| Notes |
| 2018-02-27 06:59:01 | 02/27/18 APPROVED BY PLUMBING AND PUT BACK IN B1, LAC |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-02-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-07 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-07 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2018-02-07 16:10:10 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE SITE PLAN SHOWING WATER AND SANITARY. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-03-02 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2018-03-02 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-03-02 |
Time |
14:53 |
Sent To |
PC |
|
| Notes |
| 2018-03-02 14:53:51 | PROVISO | | | | | | ALL CONSTRUCTION TRAILERS SHALL BE REMOVED WITHIN SEVEN | | | DAYS OF THE FINAL CONSTRUCTION INSPECTION BY THE CITY | | | AND PRIOR TO THE ISSUANCE OF A CERTIFICATE OF | | | OCCUPANCY. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL | | | PLANNER, AT [email protected] OR (561) 822-1448. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-02-09 |
|
|
Cont ID |
|
| Sent By |
JR |
Date |
2018-02-09 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-02-08 |
Time |
16:08 |
Sent To |
PC |
|
| Notes |
|
|
|