|
 |
 |
 |
 |
 |
Plan Review Details - Permit 18010525
| Plan Review Stops For Permit 18010525 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2018-01-31 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2018-01-31 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2018-01-31 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-02-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-02-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-02-09 |
Time |
10:24 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-01-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-01-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-01-18 |
Time |
12:19 |
Sent To |
ENG |
|
| Notes |
| 2018-01-18 15:25:03 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THE LINE INDICATED AS "F" AND CONNECTED TO THE FDC | | | APPEARS TO RUN UNDER OR INTO THE BUILDING SLAB. | | | | | | THERE IS NO DETAIL INDICATED ON WHERE OR HOW THIS LINE | | | "F" ATTACHED TO THE SPRINKLER SYSTEM. | | | | | | PLEASE PROVIDE DETAILS ON WHERE THIS FDC LINE ATTACHES | | | TO THE SPRINKLER SYSTEM. | | | | | | | | | | | | 2) THE LINE INDICATED AS "F" AND CONNECTED TO THE FDC | | | APPEARS TO RUN UNDER OR INTO THE BUILDING SLAB. | | | | | | PER NFPA 13 | | | | | | 10.6 PROTECTION AGAINST DAMAGE. [24:10.6] | | | 10.6.1 PIPE SHALL NOT BE RUN UNDER BUILDINGS. | | | [24:10.6.1] | | | 10.6.2 WHERE PIPE MUST BE RUN UNDER BUILDINGS, SPECIAL | | | PRECAUTIONS SHALL BE TAKEN, INCLUDING THE FOLLOWING: | | | (1) ARCHING THE FOUNDATION WALLS OVER THE PIPE | | | (2) RUNNING PIPE IN COVERED TRENCHES | | | (3) PROVIDING VALVES TO ISOLATE SECTIONS OF PIPE UNDER | | | BUILDINGS [24:10.6.2] | | | | | | | | | PLEASE REVIEW AND CORRECT OR PROVIDE JUSTIFICATIONS. | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-02-12 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-02-12 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-02-07 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2018-02-08 10:20:54 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-01-31 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-01-31 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-01-16 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2018-01-17 11:40:16 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2018-01-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-01-18 |
Time |
|
Rev Time |
|
| Received By |
pleduc |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |