| Plan Review Stops For Permit 18010014 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2018-08-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-04 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-04 |
Time |
13:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-30 |
Time |
18:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-30 |
Time |
18:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2018-06-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-16 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-16 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-04-09 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-04-09 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2018-04-09 15:56:10 | ACTION: BUILDING PROVISO | | | | | | 1) SUFFOLK CONSTRUCTION TO CONDUCT SITE TESTING FOR | | | COMPLIANCE WITH THE 2010 FBC-B SECTIONS: | | | | | | FBC-B 2010 1207.2 AIR-BORNE SOUND. | | | | | | FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. | | | | | | THE SOUND TESTS WILL BE CONDUCTED ON A 10 INCH CONCRETE | | | SLAB UNDER THE MAIN PERMIT (15111020) AND SUBMITTED AS | | | SOON AS RESULTS ARE PRINTED AND REVIEWED BY THE | | | DESIGNER OF RECORD. | | | NOTE: SITE TESTING FOR FLOOR INSULATION WILL REQUIRE | | | THE APPLICANT TO REQUEST (IN WRITING) UNDER THE 2010 W. | | | P. B. ADMINISTRATIVE CODE SECTION 104.11 ALTERNATE | | | MATERIALS, DESIGN AND METHODS OF CONSTRUCTION FOR THE | | | SOUND UNDERLAYMENT. THE LETTER SHOULD BE MADE OUT TO | | | THE BUILDING OFFICIAL ROBERT BROWN. | | | | | | SHEET: FINISHES. UNIT: | | | FLOOR FINISHES. BLDG TYPE: TYPE I/ TYPE II FLOOR | | | INSULATION (FBC-B 2010) | | | FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL | | | NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR | | | ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE | | | QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A | | | 10 INCH CONCRETE FLOOR ASSEMBLY AS PER PLAN OR PROVIDE | | | ONSITE TESTING TO THE LISTED BELOW ASTM STANDARDS: | | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | | | | 1B) FBC-B 2014 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 1C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-03-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-03-08 |
Time |
07:17 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-03-08 |
Time |
06:44 |
Sent To |
|
|
| Notes |
| 2018-03-08 07:00:04 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 18010014 | | | ADD: 1100 S. FLAGLER DR. SUITE; 12A | | | CONT: PDC DEVELOPMENT CORP. | | | TEL: 561-793-5852 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2ND REVIEW | | | DATE: THURS. MARCH 08/2018 | | | ACTION: BUILDING PROVISO | | | | | | 1) SHEET 002-A-2 INDICATES THE USE OF TILE, MARBLE, BUT | | | THERE HAS BEEN NO SUBMISSION FOR CODE COMPLIANCE FOR | | | TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL NEED | | | TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR | | | ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE | | | QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A | | | 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | | | | 1A) COMPLIED. FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | 2B) PROVISO/ DEFERRED SUBMITTAL: FBC-B 2014 1207.2 | | | AIR-BORNE SOUND.WALLS, PARTITIONS AND FLOOR/CEILING | | | ASSEMBLIES SEPARATING DWELLING UNITS FROM EACH OTHER OR | | | FROM PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND | | | TRANSMISSION CLASS (STC) OF NOT LESS THAN 50 (45 IF | | | FIELD TESTED) FOR AIR-BORNE NOISE WHEN TESTED IN | | | ACCORDANCE WITH ASTM E 90. | | | | | | 2C) PROVISO / DEFERRED SUBMITTAL: FLAME SPREAD- FBC-B | | | 2014 603.1. EXCEPTION 2. INSULATION INSTALLED BETWEEN A | | | FINISHED FLOOR AND SOLID DECKING WITHOUT INTERVENING | | | AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX | | | OF NOT MORE THAN 200. | | | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-02-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-02-07 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-02-07 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2018-02-07 13:58:07 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 18010014 | | | ADD: 1100 S. FLAGLER DR. SUITE; 12A | | | CONT: PDC DEVELOPMENT CORP. | | | TEL: 561-793-5852 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2ND REVIEW | | | DATE: THURS. MARCH 08/2018 | | | ACTION: BUILDING PROVISO | | | | | | 1) SHEET 002-A-2 DOES NOT COMPLY WIT THE FAIR HOUSING | | | GUIDELINE IN THE KITCHEN FOR THE WIDTH BETWEEN THE | | | KITCHEN SINK AND THE ISLAND GAS RANGE. SEE REQUIREMENT | | | # 7 SECTION (1)(B) (B)CLEARANCE BETWEEN COUNTERS AND | | | ALL OPPOSING BASE CABINETS, COUNTERTOPS, APPLIANCES OR | | | WALLS IS AT LEAST 40 INCHES. | | | 100.205(C)(3)(IV) | | | | | | 2) SHEET 002-A-2 INDICATES THE USE OF TILE, MARBLE, BUT | | | THERE HAS BEEN NO SUBMISSION FOR CODE COMPLIANCE FOR | | | TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL NEED | | | TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR | | | ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE | | | QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A | | | 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | | | | 2A). FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | 2B) PROVISO/ DEFERRED SUBMITTAL: FBC-B 2014 1207.2 | | | AIR-BORNE SOUND.WALLS, PARTITIONS AND FLOOR/CEILING | | | ASSEMBLIES SEPARATING DWELLING UNITS FROM EACH OTHER OR | | | FROM PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND | | | TRANSMISSION CLASS (STC) OF NOT LESS THAN 50 (45 IF | | | FIELD TESTED) FOR AIR-BORNE NOISE WHEN TESTED IN | | | ACCORDANCE WITH ASTM E 90. | | | | | | 2C) PROVISO / DEFERRED SUBMITTAL: FLAME SPREAD- FBC-B | | | 2014 603.1. EXCEPTION 2. INSULATION INSTALLED BETWEEN A | | | FINISHED FLOOR AND SOLID DECKING WITHOUT INTERVENING | | | AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX | | | OF NOT MORE THAN 200. | | | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | 3) SUFFOLK CONSTRUCTION HAS COMPLETED SITE SPECIFIC | | | TESTING FOR (AIIC) STRUCTURE BORNE SOUND, THE BUILDING | | | DEPARTMENT DOES NOT KNOW IF THIS TESTING WILL BE MADE | | | AVAILABLE TO THE OTHER GENERAL CONTRACTORS? | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-02-07 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-02-07 |
Time |
07:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-02-07 |
Time |
07:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-01-25 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-01-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-01-25 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2018-04-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-21 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-21 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2018-04-21 09:22:47 | GAS PROVISO: | | | | | | 1. PLEASE PROVIDE MANUFACTURE SPECIFICATION FOR PRESURE | | | REGULATOR AND APPLIANCES TO VARIFY BTU LOAD. AND | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. | | | 402.2 | | | ON JOBSITE FOR SECOND ROUGH INSPECTION. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-03-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-26 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-26 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2018-03-26 11:40:33 | 1ST REVIEW: FBC 2010 5TH EDITION | | | | | | PLUMBING COMMENTS: PREVIOUS COMMENT NOT COMPLIED | | | | | | 1. PLEASE PROVIDE MANUFACTURE SPECIFICATION FOR PRESURE | | | REGULATOR AND APPLIANCES TO VARIFY BTU LOAD. AND | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. | | | 402.2 | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-02-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-26 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-26 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2018-02-26 07:21:34 | 1ST REVIEW: FBC 2010 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE PROVIDE MANUFACTURE SPECIFICATION FOR PRESURE | | | REGULATOR AND APPLIANCES TO VARIFY BTU LOAD. AND | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. | | | 402.2 | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-14 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-13 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2018-08-14 15:36:29 | SIGNATURES ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2018-08-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-10 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-08 |
Time |
13:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2018-08-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-04 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-01 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-30 |
Time |
18:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-02 |
Time |
12:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-06-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-16 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-15 |
Time |
16:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-04-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-04-02 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-03-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-26 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-06 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-02-22 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-02-22 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-01-16 |
Time |
14:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2018-08-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-08-10 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-08-10 |
Time |
14:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2018-08-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-08-01 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-08-01 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2018-08-01 16:23:56 | 5TH REVIEW FBC-2007 MECHANICAL | | | PERMIT #18010014 | | | 8/1/2018 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M-100 & M-101: THE REVISED PLAN NOW INDICATES | | | HP-F IS SUPPLYING 1350 CFMS OF SUPPLY AIR WHICH IS | | | STILL 250 CFMS SHORT OF THE UNIT'S CAPACITY OF 1600 | | | CFMS PER THE EQUIPMENT SCHEDULE. THIS UNIT STILL | | | APPEARS TO BE OVERSIZED FOR THE AREA IT IS SERVING. | | | PLEASE PROVIDE AC COOLING AND HEATING CALCULATIONS | | | SPECIFIC TO THE AREA THIS UNIT IS SERVING- SECTION | | | 503.2.2 FBC-10 ENERGY | | | CONSERVATION. | | | | | | 2) THE REVISED SHEETS M-100 & M-101 MUST BE | | | ELECTRONICALLY SIGNED AND SEALED BY THE EOR- SECTION | | | 61G15-23.005 FLORIDA ADMININSTRATIVE CODE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-07-30 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-07-25 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2018-07-30 17:40:20 | 4TH REVIEW FBC-2017 MECHANICAL | | | PERMIT #18010014 | | | 4/2518 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M100 & M101: HP-F APPEARS TO BE OVERSIZED AT | | | 4-TONS AND 1600 CFMS OF SUPPLY AIR BECAUSE THE LAYOUT | | | PLAN INDICATES IT IS ONLY REQUIRED TO PRODUCE 1000 CFMS | | | WHICH WOULD BE MORE TYPICAL OF A 2.5 TON SYSTEM- PLEASE | | | CLARIFY. | | | | | | 2) IT HAS BEEN DETERMINED THAT ALL APARTMENT BUILDOUTS | | | WILL BE DESIGNED UNDER THE 2010 FLORIDA BUILDING CODES | | | UNTIL WHICH TIME THE BUILDING RECEIVES A CERTIFICATE OF | | | OCCUPANCY. PLEASE CORRECT THE 2014 REFERENCE ON THE A-1 | | | COVER SHEET. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2018-06-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-06-08 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-06-07 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2018-06-08 10:00:32 | 3RD REVIEW FBC-2017 MECHANICAL | | | PERMIT #18010014 | | | 4/2518 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THIS IS THE 4TH REQUEST FOR ENERGY CALCULATIONS FOR | | | THE APARTMENT BUILDOUT. SUBMITTED FOR THIS REVIEW IS A | | | COVER SHEET FROM THE EOR STANTEC WHICH IS TITLED | | | "ENERGY COMPLIANCE CALCULATIONS FOR THE BRISTOL ". THE | | | COVER SHEET DOES NOT SPECIFICALLY REFERENCE THE | | | APARTMENT, AND THERE IS NO COMPLIANCE DATA TO GO WITH | | | THE SHEET, EXCEPT UPLOADED FOR REVIEW IS THE ORIGNAL | | | 2010 ENERGY GAUGE COMPLIANCE SUBMITTAL FOR THE ENTIRE | | | BUILDING. PLEASE NOTE THE NEW APARTMENT BUILDOUT IS | | | UNDER THE 2017 CODE, THEREFORE REVISED CALCULATIONS | | | SPECIFIC TO THE APARTMENT MUST BE SUBMITTED. | | | | | | 2) COMMENT #8 FROM THE PREVIOUS REVIEW ABOUT THE | | | MISSING FIRE DAMPERS FOR THE 6" FLEX DUCT AND THE O/A | | | DUCT PENETRATING THE LAUNDRY ROOM WALL STILL EXISTS. | | | PLEASE REMOVE THE FIRE-RATED WALL SYMBOL AT THE | | | PENETRATIONS IF THE WALL IS NOT RATED, OR PROVIDE THE | | | DAMPERS. | | | | | | 3) M.100: AS PREVIOUSLY REQUESTED, A SMOKE DETECTOR IS | | | REQUIRED IN THE SUPPLY TRUNK OF HP-G PER SECTION | | | 606.2.1. | | | | | | 4) M.100: ACKNOWLEDGED THAT MANUFACTURER'S | | | SPECIFICATIONS FOR THE GAS RANGE, KITCHEN EXHAUST HOOD | | | AND DUCT, AND THE DRYER WILL BE DEFERRED SUBMITTALS.L | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2018-04-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-04-25 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-04-25 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2018-04-25 10:56:07 | 3RD REVIEW FBC-2017 MECHANICAL | | | PERMIT #18010014 | | | 4/2518 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | THE 1ST AND 2ND REVIEW COMMENTS HAVE BEEN PARTIALLY | | | ADDRESSED. COMMENTS, OR PARTS OF COMMENTS REMAINING ARE | | | LISTED BELOW IN THEIR ORIGINAL NUMERICAL ORDER. | | | | | | 1) THE REQUESTED AC CALCULATIONS WERE NOT PROVIDED. | | | | | | 2) THE REQUESTED ENERGY CALCULATIONS WERE NOT PROVIDED. | | | | | | 3) INDICATE HOW OUTSIDE AIR IS BEING SUPPLIED TO THE | | | HEAT PUMPS PER TABLE 403.3, AND HOW THE O/A SUPPLY WILL | | | BE AUTOMATICALLY DAMPERED PER SECTION C403.2.4.3 FBC-17 | | | ENERGY CONSERVATION. | | | | | | 4) SHEET M1.00: THERE IS NO TEXT ON THE PLAN FOR KEYED | | | NOTES #1 & 2. | | | | | | 5) M1.00 & A-4: NON-COMBUSTIBLE DOORS ARE REQUIRED FOR | | | THE AC CLOSETS IN COMPLIANCE WITH SECTION 602.2 FBC-17 | | | MECHANICAL, AND C403.2.9.2 FBC-17 ENERGY CONSERVATION. | | | (NOT PROVIDED) | | | | | | 6) M1.00: PROVIDE A SECTION CUT OF THE COVE RETURNS | | | THAT SHOWS THE DIMENSIONS OF THE OPENING, AND WHAT | | | CONSTRUCTION MATERIALS WILL BE USED- SECTION 602.2. | | | (NOT PROVIDED) | | | | | | 7) M.100: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | GAS RANGE, EXHAUST HOOD, AND EXHAUST DUCT, AND THE | | | DRYER. (NOT PROVIDED). | | | | | | 8) M.100: IT APPEARS THAT FIRE DAMPERS ARE MISSING | | | WHERE THE 6" FLEX DUCT AND O/A DUCT ARE PENETRATING THE | | | CORE WALL SEPARATING THE HALL AND THE LAUNDRY- SECTION | | | 607.5.2. | | | | | | 9) M102.02: PLEASE INDICATE WHICH OF THE SUBDUCT | | | DETAILS APPLIES TO THE DRYER EXHAUST, THE TOILET | | | EXHAUST, AND THE RANGE EXHAUST. (NOT PROVIDED). | | | | | | 10) M.100: A SMOKE DETECTOR IS REQUIRED IN THE SUPPLY | | | TRUNK OF HP-G PER SECTION 606.2.1. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-03-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-03-21 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-03-21 |
Time |
17:36 |
Sent To |
|
|
| Notes |
| 2018-03-21 17:59:28 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #18010014 | | | 3/21/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | THE 1ST REVIEW COMMENTS WERE NOT ADDRESSED AND THE | | | REQUESTED RESPONSE LETTER FROM THE DESIGN PROFESSIONAL | | | WAS NOT PROVIDED. PLEASE NOTE THAT IT IS ACKNOWLEDGED | | | THAT ENERGY, AC, AND VENTILATION CALCULATIONS WERE | | | SUBMITTED FOR THE APARTMENT UNDER THE MAIN PERMITS FOR | | | THE BRISTOL, HOWEVER THIS IS A SEPARATE PERMIT TO BE | | | FILED FOR THE PUBLIC RECORD, AND THEREFORE IT IS | | | NECESSARY | | | | | | THAT ALL COMPLIANCES SPECIFICALLY FOR THIS UNIT | | | BUILD-OUT ARE MET. I HAVE COPIED MY 1ST REVIEW | | | COMMENTS, INCLUDING THE REQUEST FOR THE CALCULATIONS | | | BELOW- PLEASE COMPLY: | | | | | | 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | | HEAT PUMPS- SECTION C403.2.1 FBC-17 ENERGY | | | CONSERVATION. | | | | | | 2) PROVIDE AN ENERGY COMPLIANCE REPORT- SECTION C101.5 | | | | | | 3) PROVIDE MINIMUM VENTILATION CALCULATIONS FOR THE | | | SPACE IN ACCORDANCE WITH TABLE 403.1.1, AND INDICATE | | | HOW THE OUTDOOR AIR FLOW WILL BE AUTOMATICALLY | | | CONTROLLED- SEE SECTION C403.2.4.3 FBC-17 ENERGY | | | CONSERVATION. | | | | | | 4) M1.00: CLARIFY HOW SUPPLY AIR IS BEING RETURNED INTO | | | THE AC CLOSETS- SECTION 601.6. | | | | | | 5) M1.00 & A-4: NON-COMBUSTIBLE DOORS ARE REQUIRED FOR | | | THE AC CLOSETS IN COMPLIANCE WITH SECTION 602.2 FBC-17 | | | MECHANICAL, AND C403.2.9.2 FBC-17 ENERGY CONSERVATION. | | | | | | 6) M1.00: PROVIDE A SECTION CUT OF THE COVE RETURNS | | | THAT SHOWS THE DIMENSIONS OF THE OPENING, AND WHAT | | | CONSTRUCTION MATERIALS WILL BE USED- SECTION 602.2 | | | | | | 7) M.100: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | GAS RANGE, EXHAUST HOOD, AND EXHAUST DUCT, AND THE | | | DRYER. | | | | | | 8) M.100: IT APPEARS THAT FIRE DAMPERS ARE MISSING | | | WHERE THE 6" FLEX DUCT AND O/A DUCT ARE PENETRATING THE | | | CORE WALL SEPARATING THE HALL AND THE LAUNDRY- SECTION | | | 607.5.2. | | | | | | 9) M102.02: PLEASE INDICATE WHICH OF THE SUBDUCT | | | DETAILS APPLIES TO THE DRYER EXHAUST, THE TOILET | | | EXHAUST, AND THE RANGE EXHAUST. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-02-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-02-16 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-02-16 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2018-02-16 11:06:03 | 1ST REVIEW FBC-2017 MECHANICAL, ENERGY CONSERVATION | | | CODES | | | PERMIT #18010014 | | | 2/16/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | | HEAT PUMPS- SECTION C403.2.1 FBC-17 ENERGY | | | CONSERVATION. | | | | | | 2) PROVIDE AN ENERGY COMPLIANCE REPORT- SECTION C101.5 | | | | | | 3) PROVIDE MINIMUM VENTILATION CALCULATIONS FOR THE | | | SPACE IN ACCORDANCE WITH TABLE 403.1.1, AND INDICATE | | | HOW THE OUTDOOR AIR FLOW WILL BE AUTOMATICALLY | | | CONTROLLED- SEE SECTION C403.2.4.3 FBC-17 ENERGY | | | CONSERVATION. | | | | | | 4) M1.00: CLARIFY HOW SUPPLY AIR IS BEING RETURNED INTO | | | THE AC CLOSETS- SECTION 601.6. | | | | | | 5) M1.00 & A-4: NON-COMBUSTIBLE DOORS ARE REQUIRED FOR | | | THE AC CLOSETS IN COMPLIANCE WITH SECTION 602.2 FBC-17 | | | MECHANICAL, AND C403.2.9.2 FBC-17 ENERGY CONSERVATION. | | | | | | 6) M1.00: PROVIDE A SECTION CUT OF THE COVE RETURNS | | | THAT SHOWS THE DIMENSIONS OF THE OPENING, AND WHAT | | | CONSTRUCTION MATERIALS WILL BE USED- SECTION 602.2 | | | | | | 7) M.100: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | GAS RANGE, EXHAUST HOOD, AND EXHAUST DUCT. PROVIDE A | | | DETAIL SHOWING THE CONNECTION OF THE EXHAUST DUCT INTO | | | THE SHAFT. | | | | | | 8) M1.00: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | DRYER, AND PROVIDE A DETAIL SHOWING THE CONNECTION OF | | | THE EXHAUST DUCT INTO THE SHAFT. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2018-06-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-15 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-15 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-04-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-21 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-21 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2018-04-21 09:18:37 | PLUMBING PROVISO: | | | | | | 3. REINFORCEMENT FOR GRAB BARS IS REQUIRED IN ALL THE | | | BATHROOM LOCATED IN DWELLING UNIT PLEASE PROVIDE | | | DETAILS SHOWING MOUNTING HEIGHTS OF GRAB BAR BACKING. | | | PER FHA DESIGN MANUAL REQUIREMENT #6 | | | | | | 4. SHT. A-4 DETAIL #4 THE WATER PROOF MEMBRANE FOR THE | | | SHOWER PAN SHALL BE SLOPED TO THE DRAIN MIN OF 2% SLOPE | | | .PER FBC PL 417.5.2 THE WATER PROF MEMBRANE IS SHOWN AS | | | FLAT ON THE CONCRETE SLAB. THE WATER PROOF MEMBRANE | | | SHALL BE SLOPED NOT JUST THE TILE. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-03-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-26 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-26 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2018-03-26 11:39:31 | 2ND REVIEW: FBC 2010 | | | | | | PLUMBING COMMENTS: A COMMENT RESPONSE LETTER FOR | | | PLUMBING WAS NOT PROVIDED, TO EXPEDITE APPROVAL PLEASE | | | PROVIDE RESPONSE LETTER AND CONTACT PLAN REVIEWER. | | | | | | PREVIOUS COMMENTS NOT COMPLIED WITH. | | | | | | 2. PLEASE INDICATE ON THE PLAN THE SAFE HARBOR DESIGN | | | DOCUMENT THAT WAS USED TO DESIGN THIS UNIT TO THE FHA | | | REQUIREMENTS. WPB AMEND TO FBC 107.2.1 | | | | | | 3. REINFORCEMENT FOR GRAB BARS IS REQUIRED IN ALL THE | | | BATHROOM LOCATED IN DWELLING UNIT PLEASE PROVIDE | | | DETAILS SHOWING MOUNTING HEIGHTS AND LOCATION OF GRAB | | | BAR BACKING. PER FHA DESIGN MANUAL REQUIREMENT #6 | | | | | | 4. SHT. A-4 DETAIL #4 THE WATER PROOF MEMBRANE FOR THE | | | SHOWER PAN SHALL BE SLOPED TO THE DRAIN MIN OF 2% SLOPE | | | .PER FBC PL 417.5.2 | | | | | | 5. PLEASE PROVIDE MANUFACTURE SPECIFICATION AND | | | INSTALLATION GUIDE FOR THE WATER PROOF MEMBRANE FOR | | | SHOWER LINER SHALL COMPLY WITH FBC PL 417.5.2.5 | | | | | | 6. PROVIDE DETAIL FOR HEIGHT OF LAVATORY SANITARY TO | | | COMPLY WITH FHA | | | | | | 7. SHT. P001.00 THIS PROJECT IS DESIGNED UNDER FBC 2010 | | | UNDER THE BUILDING DEPARTMENT NOTES IT LIST 2014. THE | | | GAS SHALL COMPLY WITH FBC FG 2010 PLEASE CLARIFY PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-02-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-22 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-22 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2018-02-22 14:38:26 | 1ST REVIEW: FBC 2010 | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE SHOW THE DIMENSIONS ON THE CLEAR FLOOR SPACE | | | FOR THE TOILET IN THE SPEC B MASTER BATHROOM. PER FHA | | | DESIGN MANUAL REQUIREMENT #7 PG 7.43 | | | | | | 2. PLEASE INDICATE ON THE PLAN THE SAFE HARBOR DESIGN | | | DOCUMENT THAT WAS USED TO DESIGN THIS UNIT TO THE FHA | | | REQUIREMENTS. WPB AMEND TO FBC 107.2.1 | | | | | | 3. REINFORCEMENT FOR GRAB BARS IS REQUIRED IN ALL THE | | | BATHROOM LOCATED IN DWELLING UNIT PLEASE PROVIDE | | | DETAILS SHOWING MOUNTING HEIGHTS AND LOCATION OF GRAB | | | BAR BACKING. PER FHA DESIGN MANUAL REQUIREMENT #6 | | | | | | 4. SHT. A-4 DETAIL #4 THE WATER PROOF MEMBRANE FOR THE | | | SHOWER PAN SHALL BE SLOPED TO THE DRAIN MIN OF 2% SLOPE | | | .PER FBC PL 417.5.2 | | | | | | 5. PLEASE PROVIDE MANUFACTURE SPECIFICATION AND | | | INSTALLATION GUIDE FOR THE WATER PROOF MEMBRANE FOR | | | SHOWER LINER SHALL COMPLY WITH FBC PL 417.5.2.5 | | | | | | 6. PROVIDE DETAIL FOR HIEGHT OF LAVATORY VANITARY TO | | | COMPLY WITH FHA | | | | | | 7. SHT. P001.00 THIS PROJECT IS DESIGNED UNDER FBC 2010 | | | UNDER THE BUILDING DEPARTMENT NOTES IT LIST 2014. THE | | | GAS SHALL COMPLY WITH FBC FG 2010 PLEASE CLARIFY PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-14 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-14 |
Time |
18:07 |
Sent To |
|
|
| Notes |
| 2018-08-14 18:07:34 | S&S ORIGINAL PAPER A SHEETS PROVIDED | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2018-08-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-10 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-10 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2018-08-10 15:57:27 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | ARCHITECTURAL SHEETS ARE NOT DIGITALLY SIGNED AND | | | SEALED | | | | | | PROVIDE ONE PAPER SIGNED AND SEALED ORIGINAL TO RESOLVE | | | THIS COMMENT | | | | | 2018-08-10 14:34:29 | MECH DIG/SIGS GOOD | | | CCOLE- 8/10/18 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2018-08-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-04 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-04 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2018-08-04 13:54:09 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | ARCHITECTURAL SHEETS ARE NOT DIGITALLY SIGNED AND | | | SEALED | | | | | | NEW MECHANICAL SHEETS UPLOADED ARE NOT DIGITALLY SIGNED | | | AND SEALED - PLEASE CONFIRM PRIOR TO UPLOADING. IF YOU | | | DO NOT KNOW HOW TO DO SO, PLEASE CONTACT ME FOR | | | ASSISTANCE. | | | | | | PROVIDE ONE PAPER SIGNED AND SEALED ORIGINAL TO RESOLVE | | | THIS COMMENT | | | | | | E, P SHEETS OK | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-30 |
Time |
18:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-30 |
Time |
18:10 |
Sent To |
|
|
| Notes |
| 2018-07-30 18:10:26 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | ARCHITECTURAL SHEETS ARE NOT DIGITALLY SIGNED AND | | | SEALED | | | PROVIDE ONE PAPER SIGNED AND SEALED ORIGINAL TO RESOLVE | | | THIS COMMENT | | | E, P SHEETS OK | | | | | | | | | | | | | | 2018-07-30 17:43:07 | MECH SIGS OK | | | CCOLE-7/30/18 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2018-06-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-16 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-06-16 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2018-06-16 15:09:49 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | ARCHITECTURAL SHEETS ARE NOT DIGITALLY SIGNED AND | | | SEALED | | | PROVIDE ONE PAPER SIGNED AND SEALED ORIGINAL TO RESOLVE | | | THIS COMMENT | | | | | | | | 2018-04-25 11:19:41 | MECH DIG/SIGS GOOD | | | CCOLE-4/25/18 | | 2018-02-22 14:40:44 | 4/21/18 DIG SIG ON PLUMB PAGES IS GOOD/GPJ | | 2018-02-16 11:08:54 | MECH DIG/SIGS GOOD- 1ST REVIEW | | | CCOLE |
|
|